Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação Dimplex, Modelo APL150

Fabricante : Dimplex
Arquivo Tamanho: 189.93 kb
Arquivo Nome : 2b3aebad-9bb7-4968-8241-c8772c0bc783.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


However, aged or infirm persons or young children should not be left unsupervised in the vicinity of the heater unless a suitable guard is fitted • IMPORTANT – If this heater is installed in a room containing a bath or shower, it should be so installed that switches and other controls cannot be touched by a person using a bath or shower – to comply with this requirement see ‘Lock the Control Cover’ section on page 2. • If you use this heater in conjunction with an external thermal control, a programme controller, a timer or any other device which switches the heat on automatically, observe all safety warnings AT ALL TIMES since a fire risk exists when the heater is accidentally covered or displaced • The installation of this product should be carried out by an electrician or competent person and be in strict accordance with the current IEE Wiring Regulations and relevant Building Regulations • This heater must not be mounted within 150mm of curtains and other combustible materials or 100mm from a shelf or overhang • NEVER cover or obstruct the front panel in any way • DO NOT cover the heater – Do not place material or garments on the heater or obstruct the air circulation around the heater • Before connecting the heater check that the supply voltage is the same as that stated on the heater • The heater must be installed in accordance with these instructions • The heater must be mounted using the wall bracket supplied. The heater should only be operated in the upright position • The heater should be positioned in accordance to the clearances stated in these instructions • DO NOT locate this heater immediately beneath a fixed socket outlet General The compact Apollo range of radiant panel heaters are designed to provide comfortable radiant heat, with the added benefit of two rails for drying towels, in both domestic and commercial applications. Wall Mounting / Installation The heater should be positioned observing the minimum clearances stated around the heater. (see also ‘Electrical’ section) The wall bracket supplied with the heater must be used 1. Remove wall mounting bracket from back of heater by de pressing the two spring latches at the top of the heater (see Fig.1) 2. Fix wall bracket securely to wall via the three or four holes in the bracket with the appropriate fixings for the wall type (see Fig.2) 3. Present heater to wall bracket and engage the two lower slots first. Then line up and push in the top two slots until the spring latches click in to place Fig.1 Fig.2 Electrical The wires in the mains lead are coloured in accordance with the following code: GREEN & YELLOW EARTH BLUE NEUTRAL BROWN LIVE BLACK PILOT WIRE (See also ‘Pilot Wire Connection’) The heater is fitted with a length of flexible cable for connection to the fixed wiring of the premises through a suitable connection box positioned adjacent to the heater. The supply circuit to each heater must incorporate a double pole isolating switch having a contact separation of at least 3mm Model A B (Minimum) Pilot Wire Connection APL100 468 225 The BLACK control wire is designed to carry a signal from slot in or wall mounted Dimplex APL150 618 285 programmers. If, however a programmer is not being used, the pilot wire should be isolated in accordance with the current IEE Wiring Regulations. Do NOT connect the BLACK pilot wire to earth Any 240V insulated cable may be used to link pilot wires around the ring main. A low signal current is used. Suitable connections would be either an additional single core wire marked or colour coded appropriately or use a 4 core cable throughout the ring main. Please refer to the relevant programmer installation and operating instructions for further details on pilot wire connection Operation Mode Selection Dial (A) Use this rotary dial to select the function you require Symbol Function Description Heater will switch on to provide frost Frost Protection protection if the room drops below 5.C Advice on Using your Heater • For greatest economy switch the heater to economy (setback) if you leave the room for long periods of time or before going to bed. • Do not set the comfort level too high. Even small reductions on the thermostat setting can save a lot of energy. • If you go away for a long period of time select the frost protection setting on the function dial or reduce the thermostat setting to a lower level. Locking the Thermostat Setting (C) If necessary you can lock the thermostat dial to a single setting or range. To lock the settings, use a small pair of narrow nosed pliers to pull out the locking pins at the rear of the thermostat dial. The following settings can be obtained: (see Fig.4) • Single setting – Set thermostat dial to desired setting (eg no.6). Locate one pin directly opposite the setting required • Minimum setting – Set thermostat dial to desired setting (e.g. no.6). Locate one pin opposite the setting required and one hole to the left. (The thermostat will now be adjustable from 6-9 only) • Max...

Este manual também é adequado para os modelos :
Eléctrico - APL100 (189.93 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias