Log:
Assessments - , GPA: ( )

Instruções de Operação Marley Engineered Products, Modelo RK Series

Fabricante : Marley Engineered Products
Arquivo Tamanho: 99.96 kb
Arquivo Nome : jrk_instr.pdf

Língua de Ensino: en

O documento está colocado, por favor, espere
O documento está colocado, por favor, espere

Facilidade de uso


Please carefully read the installation and maintenance instructions shown in this manual. You should enjoy years of efficient heating comfort with this product from Marley Engineered Products... the industry’s leader in design, manufacturing, quality and service. ... The Employees of Marley Engineered Products WARNING ! Read Carefully - This instruction sheet contains vital locations as described by the National Fire Protection information for the proper installation, use and efficient Association (NFPA). This heater has hot and arcing operation of the heater. Carefully read the manual before or sparking parts inside. DO NOT use in areas where installation, operation, or cleaning of the heater. Failure to gasoline, paint, or other flammable liquids or stored. adhere to the instructions could result in fire, electric 5. This heater is intended for ceiling installation ONLY. shock, death, serious personal injury, or property dam-The following clearances MUST be maintained: age. Save these instructions and review frequently for a) Top of heater to ceiling - 3 in (76 mm). continuing safe operation and instructing future users. b) Bottom of heater to floor - 7 ft (2.1m). RISK OF FIRE, ELECTRICAL SHOCK OR FALLING: c) Side of heater to wall - 12 in (305 mm). d) End of heater to wall - 12 in (305 mm). 1. To prevent electrical shock, disconnect all power e) Side of heater to side of adjacent heater - 36 in coming to heater at main service panel before wiring (914 mm). or servicing. f) End of heater to end of adjacent heater - 36 in (914 2. All wiring must be in accordance with the National mm). and Local Electrical Codes and the heater must be 6. Heater MUST be securely fastened to the building grounded as a precaution against possible electric structure to prevent it from falling. shock. 7. DO NOT stack or store combustible materials in the 3. Verify the power supply voltage coming to heater radiation path under the heater. At least 5 feet (150 matches the ratings printed on the heater nameplate mm) clearance MUST be maintained between bot before energizing. tom of heater and combustibles stored. 4. This heater is NOT suitable for use in hazardous SAVE THESE INSTRUCTIONS 1 DO NOT HANDLE QUARTZ LAMP OR QUARTZ TUBE HEATING ELEMENTS WITH BARE HANDS AS SALT IN PERSPIRATION MAY DETERIORATE THE QUARTZ. CAUTION ! ! INSTALLATION OF ELEMENTS 1. Place heater on flat surface and remove both wiring compartment covers. 2. Remove the outside hex nut from both ends of the element. 3. Place the element in the “L” shaped slots in the heater housing. 4. Install ring terminal on factory installed wire assemblies on the threaded studs on both sides of element. See Fig. 1. Fig. 1 Quartz Tube Ring Terminal Hex Nut 5. Replace hex nut and secure 6. Replace wiring compartment covers. APPLICATION LIMITATION AND PRECAUTIONS • Hazardous Atmosphere - These heaters are not suitable for use in hazardous locations. • Indoor Use Only • Ceiling Mount Only - Do not mount to walls. • Maintain at least 5’ (1.5 m) in radiant path between bottom of heater and combustible material. • Corrosive Atmospheres -The high quality finish and steel internal sheet metal parts will give excellent service under most operation conditions, including coastal salt air and most industrial atmospheres. However, the finish is not intended for salt spay exposure in marine applications or highly corrosive greenhouse, swimming pool, chemical storage or industrial atmospheres. • The mounting structure and anchoring hardware must be capable of reliably supporting the total weight of the heater and all accessories. HEATER SELECTION CHART Model No. Volts Watts Reflective Angle Dimensions Wt. lb (kg.) Height in. (mm) Width in. (mm) Length in. (mm) RK41512 120 1500 RK42020 208 2000 RK42024 240 2000 RK42027 277 2000 46 (1168) 9 (4.1) RK42034 347 2000 RK42048 380 2000 RK42060 600 2000 60 (Sym) 3.375 (86) 5.5(140) RK53020 208 RK53024 240 RK53027 277 3000 RK53034 347 57 (1448) 11 (5.0) RK53048 480 RK53060 600 OPTIONAL MECHANICAL ACCESSORIES Model No. Description Carton Wt. Qty. lbs (gr.) WG46 WG57 Wire Guard 1 1 (454) 1.5 (680) RP-WMB Wall Mounting Bracket 1 2 (907) HOW TO ORDER REPAIR PARTS In order to obtain any needed repair or replacement parts, warranty service or technical information, please contact Marley Engineered Products Service Center toll- free by calling 1-800-642-HEAT. When ordering repair parts, always give the information listed as follows: 1. The Part Number 2. The Model Number 3. The Part Description 4. Date of Manufacture SPX Corporation 470 Beauty Spot Rd. East Bennettsville, SC 29512 USA Part No. 5200-2395-000 PPD 024 8/00 2 INSTALLATION OF HEATER 1. Cut suspension chain (approved) to desired mounting length. 2. Attach chain to heater with “S” hooks provided. Heater must be mounted so that element is horizontal 3. Tilt heater (if desired) by adjusting chains as shown in Fig 2. Fig. 2 WIRING 1. Supply wiring coming to heater must be rated at least 90 degrees C. US...

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias