|
Facilidade de uso
Install the wheels (6) on the axle. IMPORTANT: The extended hub of the wheel should be positioned to- " ward the wheels support frame. Position the cap nuts (9) on the axle ends and gently tap with a hammer to secure. 2. Position the heater on the wheel support frame assembly with the combustion chamber end over the wheels. 3. Use four screws (7) and nuts (8) to attach the front handle to the top of the tank flange. The screws will go through the front handle, the tank flange and the wheel support frame. Install the nuts fingertight only. 4. Using four screws (7) and nuts (8) install the rear handle (3) as outlined in Step 3. 5. Tighten all nuts. 6. Remove tape from the fuel filler neck and install the fuel cap. WIRING DIAGRAMS Installation MODELS 2E510A &2E511A PHOTO CELL WHT MODEL 3E218A GRHf r-HMOTORh WHT WHT BLK LrO>- _i_ SPARK ■=■ PLUG r I H _ С U С MTR L L xfmrl l LINE UNE MTR ST ici 1! L ft M ft X I и T U F N R M E R SAFETY CONTROL "h RESET -J BUTTON TRANSFORMER POWER CORD GRN J— О MODEL 3E219 BLACK CIRCUIT BREAKER RED SAFETY CONTROL GREEN BLUE PHOTO CELL /< WHITE WHITE BLUE WHITE RED \T\7M TRANSFORMER V BLACK MOTOR RED Bk MOTOR START RELAY 'RED —I* WHITE SPARK PLUG WHITE FORM 5S1792 MODELS 2E510A, 2E511A, 3E218A & 3E219 01582 Operation FAN WARNING: USE ONLY IN WELL VENTILATED AREAS. SEE CHART BELOW. FRESH AIR OPENING REQUIREMENTS Note: If more than one heater is being used provide additional fresh air. HEATER SIZE 30.000 Btu 50.000 Btu 100.000 Btu 150.000 Btu SQUARE FEET OPENING 1.0 1.5 3.0 4.5 FLUSH MOTOR SHAFT When replacing the fan on the motor shaft, place fan hub flush with the motor shaft as shown. Example: A 50,000 Btu heater will require a two car garage door raised two inches or a single garage door raised four inches. A window can also be used for ventilation. The 50,000 Btu heater requires at least two thirty-inch windows raised 3.5 inches. FUELS 1. Use only kerosene, or No. 1 fuel oil. 2. Never use gasoline, naptha, paint thinners, alcohol or other volatile fuels. 3. Use of No. 2 fuel oil or No. 2 diesel oil may result in: a) More frequent clogging of fuel filters and nozzles b) The formation of carbon on the spark plug. 4. Do not allow spark plug to get a carbon buildup on the electrodes. Carbon deposits can cause interrupted starting and raw fuel emission from the heater. FUELSOURCE Fuels can be purchased at your local gasoline service station or look in the telephone directory under “kerosene” to find another source. NOZZLE Clean at least once during heating season. Remove burner head. Use a socket wrench only to remove nozzle. Blow through the face (outlet) end ONLY. CAUTION: Protect nozzle face from damage while out of the heater. SPARK PLUG After every 300 hours of operation, clean and adjust spark plug electrodes. Adjust gap or replace spark plug as required. .050 Maintenance WARNING: ALWAYS UNPLUG HEATER BEFORE SERVICING. Bend Here To Adjust Gap .050 CAUTION: When removing motor from the heater, always remove the fan first. The weight of the motor resting on the fan could damage fan pitch. FAN BLADES Clean after every 500 hours of operation or as necessary. Use a soft cloth moistened with kerosene or solvent, then dry thoroughly. ADJUSTMENT OF PUMP PRESSURE 1. Remove the plug from the air filter housing and install the pressure gauge. (HA1180) 2. To adjust the pump pressure, turn the pressure relief valve in to raise, out to lower. See Specifications for correct pressure. 3. After adjustment, remove the gauge and replace the plug. —4— FORM 5S1792 MODELS 2E510A, 2E511A, 3E218A 4 3E219 01582 AIR FILTERS Maintenance Check frequently for dust film. To clean, remove the filter from housing, wash with mild detergent and dry thoroughly before replacing. Replace once each season. CAUTION: Do Not oil the filter elements. STORAGE CAUTION: Store heater in a dry location, free of corrosive fumes and dust. WARNING: ALWAYS UNPLUG HEATER BEFORE SERVICING. LINT FILTER AIR INTAKE FILTER OUTPUT AIR FILTER MODELS 2E510A& 2E511A FILTER HOUSING END COVER FUELTANK Drain all fuel from tank. Clean and flush tank before storing. AIR FILTERS Remove and clean, or replace filters if necessary. SPARK PLUG Clean and adjust spark plug, or replace if necessary. UMITED WARRANTY Dayton portable oil fired heaters, Models 2E510, 2E511A, 3E218A &3E219are warranted by Dayton Electric Mfg. Co. (Dayton) to the original user against defects in workmanship or materials under normal use (rental use excluded), for 90 days after date of purchase. Any part which is determined to be defective in material or workmanship and returned to an authorized service location, as Dayton designates, shipping costs prepaid, will be repaired or replaced at Dayton’s option. For warranty claim procedures, see "Prompt Disposition" below. This warranty gives purchasers specific legal rights, and purchasers may als...
Este manual também é adequado para os modelos :Eléctrico - 3E218A (859.02 kb)
Eléctrico - 3.00E+219 (859.02 kb)
Eléctrico - 2E510A (859.02 kb)