|
Facilidade de uso
F. Before operating the appliance for the first time or after it has been off for an extended time, perform the following checklist: 1. Remove debris or other articles from inside the heater and the area around the heater and its exhaust vent. Make sure the ventilation openings are clear of debris or obstruction. For installations in an enclosed space, make sure openings for combustion and ventilation air are unobstructed. 2. Keep heater area clear and free from combustibles, flammable liquids and chemicals. 3. Check that all water connections are tight. 4. Water must be flowing through the heater during operation. Make sure that pool/spa is filled with water and have pump operating. Check that water flow is unobstructed from the appliance. When operating for the first time or after an extended shutdown, run filter pump for several minutes to clear all air from the system. SPA TEMPERATURE CAUTION All safety rules recommended by the U.S. Consumer Product Safety Commission should be observed when using a spa or hot tub, including: 1. Spa or hot tub water temperatures should never exceed 104°F (40°C). A temperature of 100°F (38°C) is considered safe for a healthy adult. Special caution is suggested for young children. 2. Drinking of alcoholic beverages before or during spa or hot tub use can cause drowsiness which could lead to unconsciousness and subsequently result in drowning. 3. Pregnant women beware! Soaking in water above 102°F (39°C) can cause fetal damage during the first three months of pregnancy (resulting in the birth of a brain-damaged or deformed child). Pregnant women should follow the 100°F (38°C) maximum rule. 4. Before entering the spa or hot tub, users should check the water temperature with an accurate thermometer; spa or hot tub thermostats may err in regulating water temperature. 5. Persons with medical history of heart disease, circulatory problems, diabetes or blood pressure problems should obtain their physician’s advice before using spas or hot tubs. 6. Persons taking medications which induce drowsiness, such as tranquilizers, antihistamines or anticoagulants, should not use spas or hot tubs. OPERATING INSTRUCTIONS 1. STOP! Read the safety information above. 2. Set both pool and spa thermostats to the lowest settings. 3. Turn off all electric power to the appliance. 4. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 5. Remove the jacket cover(s) by unfastening the screws connecting both halves of the top jacket. See Figure 3. 5 FIGURE 3: Removal of Jacket Covers 6. Turn the knob on the gas control clockwise ( ) to the black line, depress slightly, and turn to “OFF” position. See Figure 4. You are here You are here Gas control is shown ON. Turn Clockwise and press down to turn gas off. ON OFF OFF Gas is now OFF 2671 1096 Indexing Point FIGURE 4: Turning Gas Control OFF 7. Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the “Before Startup” instructions (Page 4). If you don’t smell gas, go to the next step. 8. Turn the knob on the gas control counter-clockwise ( ) to the “ON” position. See Figure 5. Indexing Point Gas control is shown OFF. Turn Counter-clockwise and release to turn gas on. You are here You are here OFF ON ON Gas is now ON. 2672 1096 FIGURE 5: Turning Gas Control ON 9. Replace jacket cover(s). All jacket covers must be in place when operating the appliance. 10. Set 3-way valves on inlet and outlet to pool or spa, as appropriate. 11.Turn on all electric power to the appliance. 12. Press either the POOL ON or SPA ON button switches on the operating control. 13. Set the thermostat to desired setting (NOTICE: Set point must be above actual water temperature or burner will not fire). See OPERATING CONTROL below. 14. The blower should come on immediately, and after about 20 seconds, the burner should fire. When operating for the first time, the burner may not fire on the first try because of air in the gas line. If it does not fire at first, push the OFF switch, wait five minutes, and again push the POOL or SPA ON switch. The burner should fire after about 20 seconds. You may have to repeat this until all of the air has cleared the gas line. 15. The burner should fire until the pool/spa temperature reaches the desired temperature set on the thermostat. The blower will continue to run for about 45 seconds after the burner shuts off. If any of the safety interlocks should open during burner operation, the burner shuts off immediately, but the blower continues to run for about 45 seconds. Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the appliance. 16. If the appliance will not operate, follow the instructions “TO TURN OFF GAS TO THE APPLIANCE”, and call your service technician or gas supplier. TO TURN OFF GAS TO THE APPLIANCE 1. Depress OFF button on operating control. 2. Turn off...
Este manual também é adequado para os modelos :Eléctrico - SR400NA (1.73 mb)
Eléctrico - SR400LP (1.73 mb)
Eléctrico - SR400HD (1.73 mb)
Eléctrico - SR333NA (1.73 mb)