Log:
Assessments - 3, GPA: 4.3 ( )

Instruções de Operação Amcor, Modelo Air Cooler & Heater AC 706 AM

Fabricante : Amcor
Arquivo Tamanho: 401.14 kb
Arquivo Nome : d3434767-44cb-42db-875b-087802f7ae76.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


• Don’t lift or move by pushing the unit at the rear, but always at the side. GB 3 GB • Never operate this appliance if it has a damaged cord or plug. Do not lead the cord over sharp edges. • A damaged supply cord should be replaced by the manufacturer, its service agent or a qualified person in order to avoid a hazard. • Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to do so could result in a loss of warranty. WARNING Do not use your AC 706 AM under the following conditions: Close to a naked flame Inside unit exposed to the weather outdoors Near water If the power cable wires are frayed or cut When small children may be left unattended If an extension lead may become overloaded Where the power cable may be damaged On a slope or uneven surface Where it may be damaged by chemicals Where there is a risk of interference by foreign objects This products is not made for DIY repair If there is a risk of liquid falling on the unit Reminder: Waste electrical products must not be disposed of with household waste. This product should be taken to your local recycling centre for safe treatment. 4 PARTS room air water dust proof net filter REAR rating label air filter fix screws rear net castors FRONT control panel water and ice cubes air vent reservoirs water level indicator cool/hot switch EVAPORATIVE COOLING HEATING hot air room air water dust proof net filter rotating soaked air filter belt cooled air after the evaporation of water on air filter electric resistance heating element stationary air filter GB HOW IT WORKS 5 GB CAUTIONS • Do not pour water into the ice tank. • When the product is not in use, make sure the timer switch is left in the 'OFF' position. • Do not place the unit directly against curtains or walls. • Moving of the unit should be slow and with the unit positioned sideways. Be careful not to knock the unit over! • Do not place objects on the unit. • Do not obstruct the flow of air. • Wash the filter and water tank every 2 weeks. • Do not leave/store with water inside. 'swing' push button 'on/off' and 8 hour timer switch 'speed' switch 'L' and 'H' button switch for heater 'cool' push button OPERATION 1. Pour clean, cold water through the water hole. Stop the water supply when the indicator reaches the red point. 2. Or store ice cubes into the ice tank, the cool air will be colder and more comfortable than the water you supply. 3. Plug the unit into the correct voltage. 4. Turn the timer switch to ON or adjust the timer to switch OFF in up to 8 hours. 5. Adjust speed switch to the desired cool air. 'H' for high, 'M' for medium, 'L' for low fan speed. 6. Push the cool button ON, the air filter will rotate, a mist of cool air will come out about 3 minutes later. When the cool button is OFF, only dry filtered air will be supplied. 7. Push the swing button ON, the louvres will make a 120° sweep. Or switch the swing button to OFF and choose the desired air direction manually. 8. Move the louvres of the air vent to direct the air higher or lower. ice cubes reservoir water reservoir 6 1. Unplug and position in an area where water will do no damage. 2. Place a container behind the unit, loosen the knob at the rear low plate and the water will flow from the tank into the container. 3. Unscrew and release the rear plate. 4. Pull out the terminals and take out the air filter together with the rear plate. 5. Clean the air filter. Be careful not to splash the small motor with water. Do not wash the small motor with running water. 6. Replace the air filter, screw back the rear plate and replace the knob. Pull out the terminals Air filter Unscrew Small motor Do not dip the small motor in water. Don’t wash the small motor with running water. Rear plate HOW TO CLEAN THE AIR FILTER AND WATER TANK Voltage and frequency 220 - 240 V / 50 Hz Power cool: hot: W 75 - 91 860 - 1040 (L) / 1720 - 2090 (H) Water consumption (at room temperature 28°–33°C and relative humidity 55–60%) L/h 0.5 Water reservoir capacity 9 litres for upto 18 hours continuous usage at 28°–33°C (55–60% relative humidity) Ice cubes reservoir L 4.2 Dimensions (W x D x H) cm 43.5 x 34 x 64.5 Net weight kg 10.5 TECHNICAL DATA GB 0 4 2 4 2 13 1 9 M A 6 07 C A Hong Kong China Shan Xia Industrial Development Zone, Heng Li Town, Dongguan City, Guangdong Province, China Plant One - Amcor (China) Ltd Tel: +86 769 8372 1090 Fax: +86 769 8372 1790 Email: amcorcn@amcorgroup.com Plant Two - Amcor Appliances Ltd Tel: +86 769 8372 1970 Fax: +86 769 8372 1790 Email: amcorappl@amcorgroup.com Amcor Ltd Suite 2007, Tower 6, The Gateway, Harbour City, 9 Canton Road, Tsim Sha Tsui, Kowloon, Hong Kong Tel: +852 2997 6865 Fax: +852 2997 6091 Email: amcorhk@amcorgroup.com United Kingdom Amcor Ltd 9 Ryan Drive, West Cross Centre, Great West Road, Brentford, Middlesex, TW8 9ER, United Kingdom Tel: +44 20 8560 4141 Fax: +44 20 8232 8814 Email: amcoruk@amcorgroup.com USA Amcor Inc. 685A Gotham Pa...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias