|
Facilidade de uso
Your dealer or your local gas supplier will be able to refer a qualified service person. WARNING: Due to high temperatures, the HEATER should be located out of traffic and away from furniture and draperies. The surface of the Heater Is hot when it is in use. Young children should be watched carefully when they are in the same room when the Heater is in use, and they should be taught to avoid the hot surface. Keep any objects that can burn well away from the Heater, and observe the recommended clearances that follow. Locating The Stove In choosing a location for the stove, consider: • The location of outside walls; • Where additional heat is needed: • Where family members gather most often; • The vent system requirements. NOTE: We do not recommend the use of wallpaper next to this stove. Over time, radiant heat may cause the wallpaper to shrink, or may adversely affect the binders in the wallpaper adhesive. Direct Vent System Only D. Cross Corner E. Flat on wall ABECD A. Flat on corner wall B. Room Divider C. Island ST207a Fig. 2 Possible stove locations. Clearance Requirements Minimum Clearances to Combustible Materials Measure side clearances as shown in Figures 3, 4 and 5 from the outer edge of the cast iron stove top. Measure rear clearances from the outermost surface of the steel rear skirt. The Radiance heater is approved for installation into an alcove constructed of combustible materials to the dimensions and clearances shown on the next page. The same clearances apply in a standard parallel installation. WARNING: • Always maintain required clearances (air spaces) to nearby combustibles to prevent fire hazard. Do not fill air spaces with insulation. All venting components must maintain a 1” (25mm) clearance to combustible materials. Maintain a 6” (150mm) clearance when using single wall pipe. • The gas appliance and vent system must be vented directly to the outside of the building and never be attached to a chimney serving a separate solid fuel or gas-burning appliance. • Refer to the manufacturer’s instructions included with the venting system for complete installation procedures. Radiance Direct Vent/Natural Vent Gas Heater Parallel Installation: Minimum Clearance and Flue Centerline, Direct Vent and Natu ral Vent ST130 42" (1070mm) Min. Alcove Width 48" (1220mm) Max. Alcove Depth 6" (150mm) 6" (150mm) 4" (102mm) Fig. 3 Parallel installation, minimum back and side clearances, and flue centerlines. Corner Installation: Minimum Clearance and Flue Centerline, Direct Vent & Natural Vent ST129 18" (457mm) 18" (457mm) 6" (150mm) 6" (150mm)... ... Fig. 4 Corner installation, minimum corner clearances and flue centerline. Wall Centerline from Floor A A Effective Minimum Centerline 57” (1448mm)(Vermont Castings/Majestic Pipe) 55” (1399mm) (Simpson DuraVent Pipe) ST131b Direct Vent Only Fig. 5 Minimum wall centerline. * needed for installing DuraVent Minimum Vent Kit #2792 or CFM Corporation Minimum Vent Kit #7TFSMSK. ACDBA: Rear Wall 4” (102mm) B: Min. Clearance 44” (1118mm)* C: Min. Alcove Height 72” (1830mm)* D: Max. Alcove Depth 48” (1220mm) Sidewall Clearance 6” (150mm) ST101b Fig. 6 Dimensions and clearances to ceiling or alcove. Direct Vent Only Wall and Ceiling Clearances Hearth Requirements The Radiance Heaters must be installed on rigid flooring. When the heater is installed directly on any combustible surface other than wood flooring, a metal or wood panel extending the full width and depth of the unit must be used as the hearth. There are no other hearth requirements. Radiance Direct Vent /Natural Vent Gas Heater Gas Specifications Max. Input BTU/h Min. Input BTU/h Model Fuel Gas Control RDVODRN Nat Millivolt 35,000 25,000 RDVODRP Prop Millivolt 35,000 27,500 RDVODRFN Nat Comfort Control 35,000 25,000 RDVODRFP Prop Comfort Control 35,000 27,500 Weight: Fully assembled; 350 lbs. Gas Inlet and Manifold Pressures Inlet Minimum Natural LP (Propane) 5.5” w.c. 11.0” w.c. Inlet Maximum 14.0” w.c. 14.0” w.c. Manifold Pressure 3.5” w.c. 10” w.c. Radiance Direct Vent/Natural Vent Certified to: ANSI Z21.88b-2002 / CSA 2.33b-2002 Vented Gas Fireplace Heaters The installation of your Vermont Castings stove must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition, or CSA B149.1 Installation code. (EXCEPTION: Do not derate this appliance for altitude up to 4,500 feet (1,370m). Maintain the manifold pressure at 3.5” w.c. for Natural Gas and 10.0” w.c. for LP Gas. High Elevations Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370m) above sea level. For elevations above 4,500 feet (1,370m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction. In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370m). WARNING: Improper installatio...
Este manual também é adequado para os modelos :Eléctrico - RDVOD 3360 (1.74 mb)
Eléctrico - RDVOD 3369 (1.74 mb)
Eléctrico - RDVOD 3390 (1.74 mb)
Eléctrico - RDVOD 3399 (1.74 mb)