Log:
Assessments - 5, GPA: 4.2 ( )

Instruções de Operação Lennox Hearth, Modelo SHGL-24VP-R

Fabricante : Lennox Hearth
Arquivo Tamanho: 821.19 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Turn remote wall switch “OFF.” The pilot will remain lit for normal service. 4. Depress gas control knob slightly and turn clockwise to “OFF.” Do not force. 2. For complete shutdown, turn remote wall switch to “OFF.” 5. Close lower control compartment. 3. Access the lower control compartment. OBSERVED PROBLEM OBSERVED PROBLEM REMEDY 1. When igniter button is pressed, there is no spark at ODS/pilot. A. Igniter electrode positioned wrong. Replace igniter. B. Igniter electrode broken. Replace igniter. C. Igniter electrode not connected to igniter cable. Reconnect igniter cable. D. Igniter cable pinched or wet. Free igniter cable if pinched by any metal or tubing. Keep igniter cable dry. E. Piezo igniter nut is loose. Tighten nut. F. Broken igniter cable. Replace igniter cable. G. Bad piezo igniter. Replace piezo igniter. 2. Heater produces unwanted odors. A. Heater burning vapors from paint, hair spray, glues, etc. Ventilate room. Stop using odor-causing products while fireplace is running. B. Gas leak. See Warning statement on the front page. Locate and correct all leaks. 3. Heater shuts off in use (ODS operates). A. Not enough fresh air is available. Open window and/or door for ventilation. B. Low line pressure. Contact local gas company. C. ODS/pilot is partially clogged. Clean ODS/pilot. 4. Gas odor even when control knob is in “OFF” position. A. Gas leak. See Warning statement on the front page. Locate and correct all leaks (see Checking Gas Connections, page 6). B. Control valve defective. Replace control valve. 5. When igniter button is pressed, there is spark at ODS/pilot, but no ignition. A. Gas supply turned off or manual shut-off valve closed. Turn on gas supply or open manual shut-off valve. B. Control knob not in “PILOT” position. Turn control knob to pilot position. C. Control knob not pressed in while in “PILOT” position. Press in control knob while in pilot position. D. Air in gas lines when installed. Continue holding down control knob. Repeat igniting operation until air is removed. E. ODS/pilot is clogged. Replace ODS/pilot assembly or get it serviced. F. Gas regulator setting is not correct. Replace gas regulator. 6. ODS/pilot lights, but flame goes out when control knob is released. A. Control knob not fully pressed in. Press in control knob fully. B. Control knob not pressed in long enough. After ODS/pilot lights, keep control knob pressed in 30 seconds. C. Manual shut-off valve not fully open. Fully open manual shut-off valve. D. Thermocouple connection loose at control valve. Hand tighten until snug, then tighten ... turn more. E. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: 1). Low gas pressure 2). Dirty or partially clogged ODS/pilot 1). Contact local gas company. 2). Replace ODS/pilot assembly or get pilot serviced. F. Thermocouple damaged. Replace thermocouple. G. Control valve damaged. Replace control valve. 7. Burner does not light after ODS/pilot is lit. A. Burner orifice is clogged. Clean burner or replace burner orifice. B. Burner orifice diameter is too small. Replace burner orifice. C. Inlet gas pressure is too low. Contact local gas company. 8. Delayed ignition of burner. A. Manifold pressure is too low. Contact local gas company. B. Burner orifice is clogged. Clean burner or replace burner orifice. 9. Burner backfiring during combustion. A. Burner orifice is clogged or damaged. Clean burner or replace burner orifice. B. Burner damaged. Replace burner. C. Gas regulator defective. Replace gas regulator. 10. Slight smoke or odor during initial operation. A. Vapors from paint or curing process of logs. Problem will stop after a few hours of operation. Superior recommends running the heater with the excess ventilation for the first few hours. 11. Heater produces a whistling noise when burner is lit. A. Turning control knob to “HI” position when burner is cold. Turn control knob to “LO” position and let warm up for a minute. B. Air in gas line. Operate burner until air is removed from line. Have gas line checked by local gas company. C. Dirty or partially clogged burner orifice. Clean burner or replace burner orifice. VENTED/UNVENTED TROUBLESHOOTING GUIDE REPLACEMENT PARTS LIST (MILLIVOLT) REPLACEMENT PARTS LIST (MILLIVOLT) Description 18N/18P Part No. 24N/24P Part No. 1. Valve, Millivolt (Natural) H1203 H1203 Valve, Millivolt (Propane, L.P.G.) 901917 901917 2. Base Log Assembly H1679 H1682 3. Front Log (Separate) H1680 H1683 4. Twig H1681 H1684 5. Burner H1196 H1196 6. Piezo Ignitor 10K86 10K86 7. Pilot, Millivolt (Natural) 110344 110344 Pilot, Millivolt (Propane, L.P.G.) 901915 901915 8. Orifice, Burner (NG) 0.113 and 0.119 99K77 H1210 Orifice, Burner (LP) 0.069 and 0.072 H1213 H1209 9. Air Shutter (Natural) 102720A 102720A Air Shutter (Propane) 102720B 102720C 10. Knob Extension, On/Off 69J74 69J74 11. Knob Extension, Hi/Lo 69J95 69J95 12. On/Off Switch 27K...

Este manual também é adequado para os modelos :
Eléctrico - SHGL-18MN-R (821.19 kb)
Eléctrico - SHGL-18MP-R (821.19 kb)
Eléctrico - SHGL-18VN-R (821.19 kb)
Eléctrico - SHGL-18VP-R (821.19 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias