Instruções de Operação Carrier, Modelo 58DH

Fabricante : Carrier
Arquivo Tamanho: 2.73 mb
Arquivo Nome : 58dh-3si.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


13221 a EFFICIENCY RATING CERTIFIED ama Downflow/Horizontal Induced-Draft Gas Furnace GENERAL Before starting installation of this furnace, read these instructions carefully and completely. After installation is complete, remove the Energy Guide tag from the furnace. Also read the Procedures for Induced-Draft Gas-Fired Furnaces (packaged with furnace) for important information concerning combustion, venting, piping and other standard installation practices. Further reference can be made to the current edition of the American National Standard Z223.1 National Fuel Gas Code. The induced-draft vent system of this furnace is designed to operate at zero or negative pressure at the vent connector outlet. This furnace, therefore, complies with the National Fuel Gas Code (NFPA 54-1980 or ANSI Z223.1-1980), Part 7.14.3.b. This furnace is also listed by AGA for use with the type B1 gas vent, as described in the National Fuel Gas Code, Part 7.3.2. Each furnace is shipped from the factory completely assembled with multispeed direct-drive blower, and wired ready for indoor heating installation. All sizes feature a blower control center with easy-to-read low-voltage terminal strip to ensure proper connections. The output capacity and any representations of efficiency for this product are based on standard Department of Energy test procedures. The installed operation may vary, depending on installation, weather and other factors. ( \l NON Doiu'i n Mill! Imn.u’L in .i iniin mvu hi iniii.mim.iRil .ilmnM-ilii k \JIu-k iii.il combustion and cuculating air requirements listed in Procedures foi lnduced-Dratt Gas-1 iud luiii.Kis Oh'Ciu .ill Iol.i1 miles .im The design of the downflow/horizontal (Fig. 1 and 2) gas-fired furnace is AGA certified for installation on combustible flooring (with optional floor base), in alcoves, attics, crawl spaces, base- Fig. 1 — Furnace in Downflow Position Fig. 2 — Furnace in Horizontal Position ments, closets or utility rooms. The design of this furnace line is not AGA certified for installation in mobile homes, recreation vehicles or outdoors. © Carrier Corporation 1984 Form 58DH-3SI Fig. 3 — Dimensional Drawing (in.) installation Procedures Page Inspection ..........................................................* Location, Ventilation and Air for Combustion ..................................................* Gas Piping ........................................................* Venting ..............................................................* Supply-Air Plenum Installation (downflow) ....................................................3 *Refer to appropriate sections of Proctdures for Induced-Draft Gas-Fired Furnaces booklet packed with this furnace. Page Horizontal Attic Installation...............4 Crawl Space Installation ..................5 Filter Arrangement ....................... 5 Electrical Connections .................... 5 Sequence of Operation ....................7 Start-Up and Adjustment .................8 Care and Maintenance ....................8 Table 1 — Clearances (in.)* FURNACE TOP SIDESf BACK FRONT VENT DOWNFLOW (In Alcove or Closet)! Single-Wall Vent 1 1 0 6»* 6 Type B1 Double-Wall Vent 1 0 0 3*. 1 HORIZONTAL (In Alcove)ft Single-Wall Vent 1 1 tí 0 18 6 Type B1 Double-Wall Vent 0 1« 0 18 1 HORIZONTAL (In Closet) Single-Wall Vent 2 1 tt 3 6 6 Type B1 Double-Wall Vent 2 ut 3 3 1 HORIZONTAL (Attic or Unoccupied Spaces) Type B1 or Type L Double-Wall Vent 1 18 0 18 1 •Provide a 30-in. service clearance in front of the furnace. ■{■Indicates supply or return sides when furnace is in the horizontal position. $For installation on non-combustiblefloorsonly. For installation on combustible flooring only when installed on special base (Part No. 58DS900041). **Alcove installations require 18-in. front clearance. ttUne contact permissible only between lines formed by intersections of the top and 2 sides of the furnace jacket, and building joists, studs or framing. ¿¿Clearance shown is for the outlet side. The inlet side must maintain 6-in. clearance from flue to combustible materials with single-wall vent. Table 2 — Dimensions (in.) Furnace Size A B C Vent Diam 035,040 14-3/16 12-9/16 12-11/16 4 055,060 14-3/16 12-9/16 12-11/16 4 070,080 17-1/2 15-7/8 16 4 090,1 OO(CC) 17-1/2 15-7/8 16\ 4 090,100(DC) 21 19-3/8 19-1/2 4 110,120 24-1 /2 22-13/16 23 5 NOIl Wliu' ílíS (Un.i)SS .nul lift) m,v 1 in -11.11. es .IK IIIstillli.il 111 .1 hoi 1/iMlUll position on coinhusiihU' nu,¡inal ii is in.-Li/ss.ux if i.iis^iIk I LI i ii,k i oik ni to ohl.mi icq till i'll (>-m \uil pipe The Carrier induced-draft gas furnace is designed to accept a Carrier electronic air cleaner and humidifier. For accessory installation details, refer to applicable installation literature. © 2 Table 3 — Ratings and Performance* 080-1OOCC 95,000 77,000 100-1 OOCC pi 1 g 000 98,000 ooi) i otirjf: i 107,000 88,000 100-1OODC I 119,000 97,...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias