Facilidade de uso


The FAN speed can be adjusted by adjusting the FAN trim pot COUNTER CLOCKWISE to INCREASE the speed and CLOCKWISE to DECREASE the speed of the combustion fan. Note: If you attempt to adjust the Fuel Feed Trim Pots, use a small precision screwdriver. The Trim Pots do not make a full rotation. If using a metal screwdriver, be gentle as the plastic trim pot slot can be damaged or stripped. FAN SPEED (Convection or heating) The FAN SPEED controls the speed of the room air fan. This fan blows room air through the heat exchange tubes and back into the room. When the FEED RATE is set to a higher position, the FAN SPEED should be set higher and visa versa. When the FEED RATE is set at [3 OR 4] set the FAN SPEED to [MED]. If you forget, the room air fan's (L140) temperature limit snap switch automatically sets the fan on high when your stove is producing heat faster than the fan is carrying it into the room. This may occur when the heat control lever is set at [3 or 4] and the FAN SPEED is set to a very low or off setting. After the fan runs at this automatic high setting a few minutes, it may cycle back to its lower setting and may continue to cycle between [HIGH ] and your selected setting. The circulation (room air) fan cycling from high to low is a normal condition, as well as a safety feature of your appliance. AUGER CYCLE The AUGER CYCLE LED indicates when a electrical signal is being sent to the auger motor. It is NOT used to indicate the actual movement of the auger. When the signal is being sent the LED will be solid for 3 seconds. When the LED is off no signal is being sent. SHUTTING THE STOVE OFF HI MED LOW FAN SPEED OFF FAN SPEED AUGER CYCLE Note: DO NOT UNPLUG your stove if there is a fire going or if the stove is still active. This could result in smoke coming back into the room. Remember the EXHAUST FAN is needed to force the exhaust out of the stove. On the CCI “AcuTron” Board firmly touch the OFF touch pad. The FUEL RATE LED will turn off. The AUGER CYCLE LED will turn off. The auger will stop feeding fuel to the fire and the FAN speed LED will flash indicating that the appliance is in the “Shut Down” mode. The fire will go out and the fans will continue to run until your stove cools down at which time the fans will automatically shut off and NO LED’s will remain ON. Copyright 2004 21 Cheap Charlie Owner’s Manual Canadian Comfort Industries Dansons Group Inc. PERFORMANCE ENHANCEMENT TIPS Quality care and quality pellets will help your stove operate at its peak efficiency. Consider: If any fines are noticed in the pellets or in the hopper, you may wish to screen the pellets. Periodically check the hopper to make sure there are no fines or pellets building up in the corners of the sloping sides. Clean and polish the hopper as needed. Be diligent in performing your CLEANING and MAINTENANCE requirements. IT IS CRITICAL FOR THE CORRECT OPERATION OF YOUR STOVE THAT THE DAMPER, COMBUSTION FAN SPEED AND HI-LO FUEL FEED RATES BE SET CORRECTLY! AIR INLET DAMPER: The damper is a plate that helps control the amount of airflow supplied for combustion. With the damper pushed all the way in the airflow is at its minimum. As the damper is pulled out, more air is allowed to flow through the combustion area. It will be necessary to monitor the appearance of the flame. Start by running your heater on HIGH (#4) setting for approximately 10 minutes, then push the damper all the way in and evaluate the appearance of the flame. If your flame is smoky red / orange with evidence of soot at the top of the flame, you need more combustion air. Continue to pull out the damper about a 1/8” at a time, opening the damper as needed to obtain a flame that is yellow and a fire that is brisk enough to carry ash out of the grate, but not so brisk that it carries pellets out as well (known as “Pop corning”). Normally you should find that the damper will need to be closed two-thirds to three quarters, but will vary with length of vent run, pellet quality and elevation. Damper Adjustment Guideline Lack of Combustion Air: Symptoms of insufficient combustion air include: unburned fuel, lazy smoky or red / orange flame, excessive ash or soot, excessive buildup on glass, as well as Rubber GrometT Air Inlet excessive amounts of ash build up in the grate. Slide Rod Contributing factors: High Altitude – Lack of oxygen, Restrictive Venting, Dirty / Poor quality fuel or the burn grate may not be seated properly. Stove Back Panel Excessive Combustion Air: Symptoms of excessive combustion air include: fuel burns to quickly resulting in Right Hand smoking or smoldering pellets, white to Side Panel yellow flame, and the burning pellets will lift off the grate and fly up into the air (popcorning) Contributing factors: venting system providing excessive draft. Refer to the "Trouble Shooting Guide" section of this manual, and if necessary, contact your local Specialty Retailer, Certified HVAC Service Depot, or Dansons Group Inc. Customer ...

Este manual também é adequado para os modelos :
Eléctrico - HCF120 (1.89 mb)
Eléctrico - HCF300 (1.89 mb)
Eléctrico - HCS (1.89 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias