Instruções de Operação Empire Comfort Systems, Modelo RH-65C-1

Fabricante : Empire Comfort Systems
Arquivo Tamanho: 704.99 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


1. The chimney must be lined and sized properly. Most masonry chimneys are over sized and absorb too much heat to be considered a proper vent. If you have any doubts line the chimney with the right size liner. If it's unlined you must line it. 2. Use an insulated liner when the chimney is on the outside, three sides exposed to the weather, and there is no clay liner in the chimney. The insulation will help keep the flue gases warmer. Insulated Vent Enclosure Vented room heaters installed with the vent going directly to the outside and above the eaves can cause poor venting. The cold pipe will have a delay in proper venting and cause the room heater to shut "off" by the vent safety switch. To prevent delayed venting as well as condensation of flue products an insulated enclosure is recommended. Use type B 5" (127mm) diameter vent pipe and maintain at least a one inch (25mm) clearance to combustibles. Use metal thimble to protect vent pipe as it passes through combustibles. Figure 3 3' (.9m) MORE THAN 10' (3m) 10' (3m) 2' (.6m) HEIGHT ABOVE ANY ROOF SURFACE WITHIN 10' (3m) HORIZONTALLY Page 8 12822-2-0903 VENT SAFETY SHUTOFF SYSTEM This heater must be properly connected to a venting system. This heater is equipped with a vent safety shutoff system. Warning: Operation of this heater, when not connected to a properly installed and maintained venting system or tampering with the vent safety shutoff system, can result in carbon monoxide (CO) poisoning and possible death. This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air. REVERSIBLE VERTICAL OR HORIZONTAL DRAFT DIVERTER This room heater has a reversible draft diverter. The draft diverter is installed in the vertical position at the factory. Please use the following steps to change the draft diverter from the vertical position to the horizontal position. 1. Remove L280 vent safety switch from the draft diverter. 2. Inside your yellow instruction envelope will be a 1 1/2" x 2 1/4" (38mm x 51mm) vent safety switch hole cover plate and two (2) 1/2" screws for attachment of vent safety switch hole cover plate to the draft diverter. Attach vent safety switch hole cover plate over hole on the draft diverter from which the L280 vent safety switch was removed. 3. Remove two (2) screws at bottom of draft diverter and lift upward to remove draft diverter from the draft diverter plate. Rotate draft diverter into the horizontal position and slide back into the draft diverter plate. Attach two (2) screws into bottom of the draft diverter. 4. Remove vent safety switch hole knockout and two (2) knockouts for screws on opposite side of draft diverter. 5. Attach L280 vent safety switch to the draft diverter. 6. Repositioning of the draft diverter is completed. DRAFT DIVERTER CAN BE EITHER A VERTICAL VENT OR HORIZONTAL VENT Figure 4 This room heater is equipped with a vent safety switch. The vent safety switch will cause gas flow to the pilot to "shut off" due to improper venting or a blocked flue. If the vent safety switch continues to "shut off" the gas flow to the pilot a qualified service person must be contacted to inspect for improper venting, blockage in the vent pipe or the vent safety switch for being defective. To turn on burner, rotate dial knob toward setting number 7. To shut down burner, rotate dial knob toward setting number 1. The dial numbers 1 to 7 correspond to 50° to 90°F (10° to 32°C). This is the temperature at the bulb thermostat not the room temperature. The owner is advised to determine the particular heat setting that is desired for comfort, as heating requirements are different for every owner. THERMOSTAT OPERATION Attention: If no heat is desired, turn the gas control knob to the PILOT position. 12822-2-0903 Page 9 1. STOP! Read the safety information above on this label. 2. Set thermostat to lowest setting. 3. Turn off all electric power to the appliance. (If applicable) 4. Remove access panel (front panel). 5. Push in gas control knob slightly and turn clockwise to “OFF”. Do not force. 6. Wait ten (10) minutes to clear out any gas. Then smell for gas, including near floor. If you smell gas, STOP! Follow “B” in the safety information above on this label. If you do not smell gas, go to the next step. 7. Find pilot - the pilot is attached to front of burner. 8. Turn gas control knob counterclockwise to “IGN”. TO TURN OFF GAS TO APPLIANCE 3. Push in gas control knob slightly and turn clockwise t o “OFF". Do not force. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas su...

Este manual também é adequado para os modelos :
Eléctrico - RH-50-6 (704.99 kb)
Eléctrico - RH-50C-1 (704.99 kb)
Eléctrico - RH-50C-1 (704.99 kb)
Eléctrico - RH-65-6 (704.99 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias