Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação Gas-Fired Products, Modelo KLH601

Fabricante : Gas-Fired Products
Arquivo Tamanho: 155.87 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Open Closed Manual Shutoff Valve Manual Shutoff Valve Checking Gas Joints Manual Shutoff Valve Combination Gas Control Location NOTE: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once. OPERATING HEATER: WARNING: Before lighting, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. If you smell gas, follow the Safety Instructions on the front page and under Section I. Page 13 Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and replace any part of the control system and any gas control component which has been under water. LIGHTING INSTRUCTIONS: 1. Read the aforementioned safety information. 2. Make sure manual shutoff valve is fully open. 3. Push in gas control knob slightly and turn clockwise to the OFF position. 4. Wait five minutes to clear any gas. Then smell for gas, including near the floor. If you smell gas, follow the safety information on the front page. If you don’t smell gas, go to the next step. 5. Push in and turn gas control knob counterclockwise to IGN PILOT. This will light the pilot. The pilot can be seen through the glass panel. If needed, keep pressing and turning the control knob counterclockwise until the pilot lights. 1 2 34 5 6 7 PILOT NOOFF IGN NOTE : If pilot does not stay lit, refer to troubleshooting Section XII. Also, contact a qualified service person, or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see the following manual lighting instructions. 6. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Page 14 Page 15 7. If pilot goes out, repeat steps 3 through 6. This heater has a safety interlock system. Wait one(1) minute before relighting pilot. 8. When the pilot is lit, turn gas control knob to ON. Turn thermostat control knob counterclockwise to desired heating level. The main burner should light. Set control knob to heat level between 7 and 1. CAUTION : Do not try to adjust heating levels by using the manual shutoff valve. TURNING OFF GAS TO HEATER Shutting Off Heater ..Turn control knob clockwise to the OFF position. Shutting Off Burner Only (Pilot stays lit) ..Turn control knob clockwise to the PILOT position. THERMOSTAT CONTROL OPERATION The thermostat used on these models differs from standard thermostats. Standard thermostats simply turn the burner on and off. The thermostat used on this heater senses the room temperature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height/input rating. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. Pilot Burner Ignitor Electrode Thermocouple 1 2 3 4 5 6 7 PILOT NO OFF IGN Note : The thermostat sensing bulb measures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation location, room size etc.). Frequent use of your heater will let you determine your own comfort levels. MANUAL LIGHTING INSTRUCTIONS 1. Remove lower front panel. 2. Follow steps 1 through 4 as stated under Lighting Instructions. 3. Press and turn control knob counterclockwise to the PILOT position. 4. With control knob pressed in, strike match, hold match to pilot until pilot lights. 5. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. 6. Replace lower front panel. INSPECTING MAIN BURNER AND PILOT BURNER Pilot Flame Pattern The following figures show a correct and incorrect flame patterns. The incorrect flame is not touching the thermocouple. This will cause a nuisance shut down. Pilot BurnerThermocouple Pilot BurnerThermocouple CORRECT INCORRECT If pilot flame pattern is incorrect as shown above, turn heater off and refer to troubleshooting guide. Burner Flame Pattern This heater allows the view of flames and provides the simulation of a solid fuel fireplace. The incorrect log position can cause flame impingement, which can cause soot formation. Propane installations seem to have more of a sooting problem due to the richness of LP gas. Page 16 WARNING : If heavy sooting occurs, your heater could produce increased levels of carbon monoxide. If gas log shows carbon deposit, turn heater off and refer to troubleshooting guide. CARE AND MAINTENANCE : Dust, list or debris may affect heater performance. The heate...

Este manual também é adequado para os modelos :
Eléctrico - 602-30 (155.87 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias