Log:
Assessments - 1, GPA: 5 ( )

Instruções de Operação Trane, Modelo XV 90

Fabricante : Trane
Arquivo Tamanho: 646.12 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


BAYFLTR200 [ ] Filter Kit/Horizontal Conversion TUY060, 080-R ......................................................................................................... BAYFLTR203 [ ] Filter Kit/Horizontal Conversion TUY100-R ................................................................................................................ BAYFLTR204 [ ] Filter Kit/Horizontal Conversion TUY120-R ................................................................................................................ BAYFLTR205 [ ] Filter Accessory Kit Upflow 14.5" Furnaces ............................................................................................................... BAYFLTR317 [ ] Filter Accessory Kit Upflow 21" Furnaces .................................................................................................................. BAYFLTR321 [ ] Filter Accessory Kit Upflow 24.5" Furnaces ............................................................................................................... BAYFLTR324 [ ] High Altitude Switch TUY060R .............................................................................................................................. BAYHALT2451 [] High Altitude Switch TUY080, 100R ...................................................................................................................... BAYHALT2461 [] High Altitude Switch TUY120R .............................................................................................................................. BAYHALT2471 [] Concentric Vent Kit ............................................................................................................................................... BAYVENT100A [ ] Sidewall Vent Termination Kit ................................................................................................................................. BAYVENT200B [ ] Manufactured/Mobile Home Kit ............................................................................................................................. BAYMFGH100A [ ] 1 Optional kit allows 200 ft. max. vent length from 5,000-12,000 feet above sea level. See installer's guide. Pub. No. 22-1682-05-0802 (EN) 5 General Data TUY-R9V PRODUCT SPECIFICATIONS1 MODEL TUY060R9V3V TUY080R9V3V TUY100R9V4V TUY120R9V5V RATINGS2 1st Stage Input BTUH 39000 52000 65000 78000 1st Stage Capacity BTUH (ICS)3 37000 49000 62000 74000 2nd Stage Input BTUH 60000 80000 100000 120000 2nd Stage Capacity BTUH (ICS)3 56000 73000 93000 112000 AFUE (ICS) 93.0 92.5 93.0 92.5 Temp. Rise (Min.-Max.) °F. 35 - 65 35 - 65 35 - 65 40 - 70 BLOWER DRIVE DIRECT DIRECT DIRECT DIRECT Dia.-Width (In.) 10 x 8 10 x 8 10 x 10 10 x 10 No. Used 1 1 1 1 Speeds (No.) VARIABLE VARIABLE VARIABLE VARIABLE CFM vs. in. w.g. SEE FAN PERF.TABLE SEE FAN PERF.TABLE SEE FAN PERF.TABLE SEE FAN PERF.TABLE Motor HP 1/2 1/2 1 1 R.P.M. VARIABLE VARIABLE VARIABLE VARIABLE Volts/Ph/Hz 115/1/60 115/1/60 115/1/60 115/1/60 COMBUSTION FAN - TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL Drive - No. Speeds DIRECT - VARIABLE DIRECT - VARIABLE DIRECT - VARIABLE DIRECT - VARIABLE Motor HP - RPM 1/15 - 5000 1/15 - 5000 1/15 - 5000 1/25 - 5000 Volts/Ph/Hz 115/1/60 115/1/60 115/1/60 115/1/60 FL Amps 1.1 1.1 1.1 1.1 FILTER — Furnished? YES YES YES YES Type Recommended HIGH VELOCITY HIGH VELOCITY HIGH VELOCITY HIGH VELOCITY Filter (No.-Size-Thk.) 1 X 17 X 25 X 1 1 X 17 X 25 X 1 1 - 20 X 25 X 1 1 - 24 X 25 X 1 VENT — Size (In.) 2 ROUND 2 ROUND 3 ROUND 3 ROUND HEAT EXCHANGER Type -Fired ALUMINIZED STEEL TYPE 1 ALUMINIZED STEEL TYPE 1 ALUMINIZED STEEL TYPE 1 ALUMINIZED STEEL TYPE 1 -Unfired Gauge (Fired) 20 20 20 20 ORIFICES — Main Nat. Gas. Qty. — Drill Size 3 - 45 4 - 45 5 - 45 6 - 45 L.P. Gas Qty. — Drill Size 3 - 56 4 - 56 5 - 56 6 - 56 GAS VALVE REDUNDANT - TWO STAGE REDUNDANT - TWO STAGE REDUNDANT - TWO STAGE REDUNDANT - TWO STAGE DIRECT IGNITION DEVICE Type HOT SURFACE IGNITER HOT SURFACE IGNITER HOT SURFACE IGNITER HOT SURFACE IGNITER BURNERS — Type IN-SHOT IN-SHOT IN-SHOT IN-SHOT Number 3 4 5 6 POWER CONN. — V/Ph/Hz4 115/1/60 115/1/60 115/1/60 115/1/60 Ampacity (In Amps) 8.4 8.4 11.4 11.4 Max. Overcurrent Protection (Amps) 15 15 15 15 PIPE CONN. SIZE (IN.) 0.50 0.50 0.50 0.50 DUCT CONN. SEE OUTLINE DRAWING SEE OUTLINE DRAWING SEE OUTLINE DRAWING SEE OUTLINE DRAWING DIMENSIONS H X W X D H X W X D H X W X D H X W X D Crated (In.) 41-3/4 X 19-1/2 X 30-1/2 41-3/4 X 19-1/2 X 30-1/2 41-3/4 X 23 X 30-1/2 41-3/4 X 26-1/2 X 30-1/2 Uncrated SEE OUTLINE DRAWING SEE OUTLINE DRAWING SEE OUTLINE DRAWING SEE OUTLINE DRAWING WEIGHT Shipping (Lbs.)/Net (Lbs.) 158/146 158/148 171/160 205/193 1 Central Furnace heating designs are certified by AGA and CSA. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 f...

Este manual também é adequado para os modelos :
Eléctrico - 120R9V (646.12 kb)
Eléctrico - 080 (646.12 kb)
Eléctrico - 100 (646.12 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias