Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação Thermo Products, Modelo OH11-105

Fabricante : Thermo Products
Arquivo Tamanho: 1.31 mb
Arquivo Nome : 319c96b2-536b-497e-ad55-b72be2433dca.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


4. A furnace installed in a residential garage must be installed so the burner and ignition source are located higher than 18 inches above the floor, unless the required combustion air is taken from the exterior of the garage. Also, the furnace must be located or protected to avoid physical damage by vehicles. . WARNING: This furnace is not to be used as a construction heater. 5. Listed below are definitions of "COMBUSTIBLE MATERIAL" and "NON-COMBUSTIBLE MATERIAL." COMBUSTIBLE MATERIAL: Material made of or surfaced with wood, compressed paper, plant fibers, plastics, or other material that will ignite and burn, whether flame resistant or not. NON-COMBUSTIBLE MATERIAL: Material that is not capable of being ignited and burned. Such materials consist entirely of, or a combination of, steel, iron, brick, tile, concrete, slate, or glass. MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS TYPE OF UNIT MODEL NO.1 FROM SIDES OF FURNACE FRONT TOP & SIDES OF PLENUM FROM THE FLUE/VENT REAR LOWBOYS OL2 1” 2” 1” 4” 1” OL5,11,16 1” 24” 1” 6” 1” OL20 1” 24” 1” 18” 1” OL33,37,39 1” 24” 1” 18” 1” HIGHBOYS OH3,11 1” 24” 1” 9” 1” OH5 1” 24” 1” 6” 1” OH16 1” 24” 1” 9” 1” OH2 1” Note3 2” 9” 1” COUNTERFLOWS OC2 1” 4” 1” 6” 1” OC5 1” 4” 1” 9” 1” TYPE OF UNIT MODEL NO.1 FRONT TOP REAR BOTTOM FROM THE FLUE/VENT ANY SIDE OF PLENUM HORIZONTALS2 OT5 24” 1” 1” 1” 4” 1” OT11,16 24” 1” 1” 1” 9” 1” Notes: 1The above are abbreviated model numbers. 2Horizontal units are not approved for attic installation. 3OH2 front clearance for 6” for Closet, 18” for Alcove. 1 All installations and services must be performed by qualified service personnel. The minimum clearances listed in the preceding table are for fire protection. Clearance for servicing the front of the furnace and the rear of the lowboy models should be at least 24 inches. A clearance of 24 inches is recommended for passage to all points on the furnace requiring service access. The OH2-3-5-11-16 furnaces may be installed on combustible flooring. The OL2-5-11-16-20-33-37-39 and OC2-5 furnaces are to be installed on non-combustible flooring only. A non-combustible floor base is available for the counterflow models OC2-5, which then allows these models to be adapted for installation on combustible flooring (use non-combustible floor base Model No.125 for OC5, Model No 56 for OC2). NOTE: The OH2 furnace is approved for closet installation. If the OH2 is installed in a closet, it requires two openings in the closet door for combustion air, each having a minimum area of 162 sq. inches. This free area for the OH2 intentionally exceeds the recommended minimum free area of 2 square inches per 1000 BTUH of input rate. NOTE: When power venting a Thermo Pride oil fired furnace with a power venting system other than the system supplied by Thermo Pride, a fiber chamber and an isolated combustion air kit (PVB or Beckett boot) is to be used with the other manufacturers power venting system. NOTE: On the front flue, lowboy, all highboy or counterflow models, it is possible to rotate the flue elbow (which is factory installed for vertical discharge) 90° counterclockwise from the vertical position to adapt to various venting systems. (See following page for details) . CAUTION MUST BE TAKEN NOT TO EXCEED 90° ROTATION (OF THE FLUE ELBOW) COUNTERCLOCKWISE OR RIGHT FROM THE VERTICAL POSITION. ROTATION OF FRONT FLUE ELBOW When an installation requires that the flue exit out the left hand side casing on a front flue unit, remove screw securing the 90 deg. elbow and rotate it 90° counterclockwise. Then, by following dimensions in Table 1, locate the center point for the exit of the flue for the particular size furnace. Once the center has been located, use a scribe to mark the hole size, listed in the chart, which corresponds with the furnace being used. Cut hole out and extend flue through side casing. A trim collar may be ordered from Thermo Products to hide the gap around the flue pipe. This trim collar, however, is not required for operation. 2 All installations and services must be performed by qualified service personnel. NOTE: ROTATION OF FLUE PIPE IS ONLY ALLOWED FOR LEFT HAND SIDE VENTING APPLICATIONS. TABLE 1: Suggested sizes and positions of flue pipe opening on left hand side of casing. TRIM COLLAR/ UNIT DIA. HOLE “X” DIM. “Y” DIM. FLUE DIA. GASKET PART # OC2 5-1/2” 3-5/8” 28-3/8” 5” 14121/330073 OC5 6-1/2” 4-3/4” 31-7/16” 6” 14131/330005 OH2 5-1/2” 3/5/8” 28-3/8” 5” 14121/330073 OH3 6-1/2” 4-9/16” 32-3/16” 6” 14131/330005 OH5 6-1/2” 4-3/4” 33-1/16” 6” 14131/330005 OH11 6-1/2” 4-3/4” 35-1/4” 6” 14131/330005 OH16 7-1/2” 4-5/16” 41-3/8” 7” 14132/330006 OL2* 5-1/2” 3-5/8” 28-5/16” 5” 14121/330073 OL5* 6-1/2” 4-5/8” 34-15/16” 6” 14131/330005 OL11* 6-1/2” 4-1/2” 37-5/8” 6” 14131/330005 OL16* 7-1/2” 4-1/2” 39-1/8” 7”...

Este manual também é adequado para os modelos :
Eléctrico - OC2-56 (1.31 mb)
Eléctrico - OC5-85 (1.31 mb)
Eléctrico - OH16-125 (1.31 mb)
Eléctrico - OH2-56 (1.31 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias