8" to less than 12" Hood not required. Less than 8" Extend heat resistant material to 8" AND install hood. See Figure 5. TBP24 TBP30 Hood not required. Hood not required. Extend heat resistant material to 12" OR install hood. See Figure 5. Extend heat resistant material to 12" OR install hood. See Figure 5. Extend heat resistant material to 8" AND install hood. See Figure 5. OR, extend heat resistant material to a height of at least 12". Extend heat resistant material to 8" AND install hood. See Figure 5. OR, extend heat resistant material to a height of at least 12". TABLE A - Heat Resistant Material Requirements with no Mantel or Combustible Projection 12 70D0004 CLEARANCES and HEIGHT REQUIREMENTS Heat resistant material (minimum requirements) with wooden mantel or other combustible projection: To install the heater with a wooden mantel, shelf or other combustible projection above, first measure the heat resistant material shown in Figure 6, then refer to Table B. 8" or More of Heat Resistan MaterialHood HEAT RESISTANT MATERIAL MEASUREMENT 12" or more 8" to less than 12" Less than 8" Heater in Fireplace or Firebox Figure 6 - Measuring Heat Resistant Material for Mantel REQUIREMENTS FOR SAFE INSTALLATION WITH WOODEN MANTEL, SHELF OR OTHER COMBUSTIBLE PROJECTIO TBP18 Hood not required. Observe profiles (side elevations) shown in Figure 7, page 14. Install hood and observe profiles shown in Figure 8, page 15; OR extend heat resistant material to at least 12" and observe profiles shown in Figure 7, page 14. Extend heat resistant material to at least 8", install hood and observe profiles shown in Figure 8, page 15; OR extend heat resistant material to at least 12" and observe profiles shown in Figure 8, page 14 TBP24 TBP30 Hood not required. Observe profile (side elevations) shown in Figure 9, page 15 Hood not required. Observe profile (side elevations) shown in Figure 9, page 15 Install hood and observe profiles shown in Figure 7, page 15; OR extend heat resistant material to at least 12" and observe profiles shown in Figure 9, page 15. Install hood and observe profiles shown in Figure 7, page 15; OR extend heat resistant material to at least 12" and observe profiles shown in Figure 9, page 15. Extend heat resistant mate-Extend heat resistant material to at least 8", install hood rial to at least 8", install hood and observe profiles shown in and observe profiles shown in Figure 7, page 15; OR extend Figure 7, page 15; OR extend heat resistant material to at heat resistant material to at least 12" and observe profiles least 12" and observe profiles shown in Figure 9, page 15. shown in Figure 9, page 15. TABLE B - Heat Resistant Material Heights and Mantel Location 70D0004 13 CLEARANCES AND HEIGHT REQUIREMENTS HeaterinFireplaceorFireboxHeatResistantMaterial10" 8" 6" 21/2" 8" 14" 201/2"245/8"28" Example: A mantel may project from the wall a maximum of 21/2" at a minimum of 14" above the opening, and a maximum of 6" at a minimum of 201/2" above the opening. Figure 7 - Minimum Mantel Clearance with No Hood -TPB18 HeaterinFireplaceorFireboxHeatResistantMaterialHood10" 12" 8" 6" 21/2" 8"141/2"185/8"221/2"26" Example: A mantel may project from the wall a maximum of 21/2" at a minimum of 8" above the opening, and a maximum of 6" at a minimum of 141/2" above the opening. Figure 8 - Minimum Mantel Clearance with Hood - All Models 14 70D0004 70D0004 15 HeaterinFireplaceorFireboxHeatResistantMaterial10"orless12"min.28" 8" 6" 7" 141/2" Figure 10 - Minimum Mantel Clearance with Hood - TPB24/30 (Example of Unsafe Installation) Figure 9 - Minimum Mantel Clearance with No Hood — TPB24/30 Example: The bottom of the mantel may project from the wall a maximum of 10" at a minimum of 28" above the opening. CLEARANCES AND HEIGHT REQUIREMENTS Figure 10 is an example of an unsafe mantel installation. This mantel projects 4" at 8" above the opening, exceeding the maximum acceptable distance of 21/2" The mantel also projects 7" at 141/2" above the opening, exceeding the maximum acceptable distance of 6". If your mantel profile is unsafe, you may either: • Raise the mantel to an acceptable height OR • Remove the mantel HeaterinFireplaceorFireboxHeatResistantMaterial10"orless12"min.28" 8" 6" 7" 141/2" Figure 10 - Minimum Mantel Clearance with Hood - TPB24/30 (Example of Unsafe Installation) Figure 9 - Minimum Mantel Clearance with No Hood — TPB24/30 Example: The bottom of the mantel may project from the wall a maximum of 10" at a minimum of 28" above the opening. CLEARANCES AND HEIGHT REQUIREMENTS Figure 10 is an example of an unsafe mantel installation. This mantel projects 4" at 8" above the opening, exceeding the maximum acceptable distance of 21/2" The mantel also projects 7" at 141/2" above the opening, exceeding the maximum acceptable distance of 6". If your mantel profile is unsafe, you may either: • Raise the mantel to an acceptable height OR • Remove the mantel 21/2" 4" FLOOR CLEARANCE The gas log heater must be installed at lea...
Este manual também é adequado para os modelos :Eléctrico - TPB18 (6.79 mb)
Eléctrico - TPB30 (6.79 mb)