Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação Signat, Modelo CSQAD

Fabricante : Signat
Arquivo Tamanho: 939.3 kb
Arquivo Nome : 75fde697-6da7-4e2e-98d9-b1e903fbfeec.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


We recommend the use of a residual current device (RCD) 2kW WHLW 10 4.0 5.24 5.49 3.3 4.11 12 3.6 4.88 4.94 3.0 3.84 14 3.2 4.51 4.39 2.7 3.57 16 3.5 4.33 4.12 2.5 3.38 18 2.84.143.84 --H = mounting height (determined by on-site requirements) L = length of the heated area W = width of the heated area Product Selector ModelReferenceRatingHeight AWidth BDepth C CSL2 75 771601 2kW 108mm 1,215mm 71mm CSL3 75 771602 3kW 108mm 1,671mm 71mm 38 +44 (0) 1733 456789 Suntube Tubular heaters Commercial space heating Suntube Tubular heaters Commercial space heating “Suntubes are the perfect answer where a steady energy efficient source of heat is needed, providing gentle background warmth and frost protection for both domestic and commercial applications. ” They are highly effective as window demisters and for horticultural use, providing invaluable, effective heating and frost protection in greenhouses and conservatories. Key features • 60-360W outputs • A range of 6 lengths and loadings • Complete with universal mounting brackets for floor or wall fixing and 1m white cable Optional accessories Technical Specification • Elements metal sheathed throughout • Polyester epoxy powder coated aluminium body • High temperature glass filled nylon end caps and brackets • Supply - 230/240V AC single phase Interlinking kit Available for multiple installations (100mm mounting centres). Ref: 85 731506 Dimensions STG guards* We recommend the use of guards for additional security in sensitive areas such as schools, hospitals and care homes. These can be obtained from C.Ainao Ltd. Tel: 020 7987 1184 Product Selector Model CST1 CST2 CST3 CST4 CST5 CST6 Reference 75 771501 75 771502 75 771503 75 771504 75 771505 75 771506 Guard short code* RatingDiameter A STG1 60 Watts 52mm STG2 120 Watts 52mm STG3 180 Watts 52mm STG4 240 Watts 52mm STG5 300 Watts 52mm STG6 360 Watts 52mm Length B 410mm 670mm 980mm 1,280mm 1,590mm 1,890mm Depth C 75mm 75mm 75mm 75mm 75mm 75mm CSIK 85 731506 Interlinking kit +44 (0) 1733 456789 39 Sunfan High level fan heater Commercial space heating Sunfan High level fan heater Commercial space heating Sunfan is a robust 3kW high volume air throughput “ “ commercial/industrial wall mounted fan heater designed to provide highly efficient heating in winter, or cool air circulation in summer. ” Key features • High air volume throughput of 300m3/hour • Quiet running, totally enclosed motor • Wall mounted with 2 part self supporting bracket • Multi-directional adjustment of 45° vertically and 150° horizontally with single screw locking • High level heating/cooling - ideal for shops and warehouses where wall space is at a premium • Double insulated • Supplied complete with variable thermostatic controller Thermostatic controller (included) For remote switching on/off and variable thermostatic control. Control options For remote switching on/off and hot/cold air circulation. Dual control switch (optional) Ref: 82 815906 Technical Specification • Flame retardant polycarbonate/glass filled nylon body • Single phase, 4 pole motor • Two tone grey (neutral colours) • Protection - Two thermal cut-outs • Supply - 230/240V AC single phase Dimensions • Minimum mounting height 1.8 metres • 150mm minimum clearance above the heater • 300mm minimum clearance on either side Product Selector ModelReferenceRatingNoise level @3m Height AWidth BDepth C CSF3 75 771401 3kW 40.5dBA 229mm 267mm 260mm CDCS 82 815906 Dual control switch 40 +44 (0) 1733 456789 Sunscreen Warm air curtains Commercial space heating Sunscreen Warm air curtains Commercial space heating “Sunscreen and Sunspot heaters provide the ideal solution for draught exclusion on external doors. When mounted on the inside of an ” external door they create a ‘hot air curtain’ to prevent cold draughts entering a building. In summer they can be switched to fan only to form a barrier against incoming dust and provide a refreshing breeze. Suitable for a range of doorway applications in commercial premises such as shops, offices, workshops and stores, the Sunscreen and Sunspot heaters are designed for fast installation with key hole-slots for vertical mounting or brackets providing complete flexibility of adjustment from vertical to horizontal. Easily accessible switches allow the option to run the unit on fan only or at half or full heat output. Key features • Two heat settings or cold • High volume throughput • Smooth running, shaded pole motor, with ‘greased-for-life’ bearings • Integral switching for ease of installation • Tangential blower Sunspot 2.25kW The Sunspot is a modular unit almost half the width of the Sunscreen. It can be used with a Sunscreen for wider doorways or on its own as a high level wall-mounted fan heater in commercial premises. Technical Specification • Element - open coil supported by ceramic insulators • Zinc coated steel, powder coated body white/grey • Shaded pole motor • Protection - therm...

Este manual também é adequado para os modelos :
Eléctrico - CSP2 (939.3 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias