Log:
Assessments - 6, GPA: 4 ( )

Instruções de Operação Louisville Tin and Stove, Modelo W351F

Fabricante : Louisville Tin and Stove
Arquivo Tamanho: 208.53 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Dry-Wall B-W Type Vent Screw Plaster Ground Front Panel FIGURE 5A - DRY WALL FIGURE 5B - PLASTER WALL Panel STEP 4.Remove double ceiling plate between studs. Install one ceiling plate spacer across the cut out in ceiling plate. Install vent pipe into position, be sure to lock bottom of vent pipe into the base plate. Nail second ceiling plate spacer in place. (See Figure C, Page 6). STEP 5.If the vent continues through additional stories within the 2x4-stud space, then fire-stop-spacers must be installed at the second and subsequent ceiling levels. See Figure D. Installation of B-W gas vent for each subsequent ceiling or floor level of multi-story buildings Firestop spacers supplied by manufacturer of B-W gas vent Plate cut away to provide passage of B-W gas vent Nail firestop spacer securely FIGURE D VENT INSTALLATION 2 FT. MIN. LISTED VENT TOP STORM COLLAR ROOF FLASHING OVAL TO ROUND ADAPTERCEILING PLATE SPACERS 12 FT. MIN. LISTED “BW” VENT PIPE BASE PLATE HEADER PLATE 2 X 4 WALL STUDS CEILING PLATE SPACER LANCES FIGURE 2 - VENT INSTALLATION Page 7 B-W VENT B-W VENT FIGURE 3 BURNER SHELF FIGURE 4 Casing “Z Bracket Front Panel Front Panel Door INSTALLATION STEP 6. To place furnace into position, grasp furnace and lift so furnace flue vent and header plate vent opening engage. Do not use burner or gas control to lift heater. Lift furnace upward and swing bottom into wall opening until legs rest on floor plate and are flush to finished wall. For proper combustion, level heater front to back and side to side. Nail legs to studs. DO NOT BEND LEGS as this will put the entire unit into a bind and cause expansion noises (See Figure 3). STEP 7. A drip leg and a manual valve equipped with a 1/8 N.P.T. plugged tapping accessible for test gauge connection should be installed immediately upstream of the gas supply connection to the appliance. Some codes and ordinances require that the manual valve be located outside the appliance. STEP 8. Make gas connection using connector the same size as gas connection of furnace. CHECK ALL CONNECTIONS FOR GAS LEAKS WITH LEAK DETECTOR SOLUTION. DO NOT USE OPEN FLAME. STEP 9. For wall thermostat units, see “Wiring” section for thermostat connections. Make sure all connections are correct and connector stems are not touching. STEP 10. To fasten front panel to furnace, be sure exposed portion of header is free of debris and plaster. Place outer panel over furnace with top of panel about one inch above header and centered in opening. Keep front panel flush to finished wall and slide down until rear flange of top outer panel is wedged tight with header and flush with wall. Open bottom door of front panel and place sheet metal screw into locking latch. Secure top of front panel to header plate with screw provided. This will hold front panel securely to wall. See Figures 5A, 5B, (See Page 7), and 5C. FIGURE 5C Page 8 CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. WIRING INSTRUCTIONS – GRAVITY WALL FURNACE WARNING: Failure to locate the thermostat properly or to wire the furnace correctly may result in continuous operation, control damage or failure to operate. This can cause property damage, personal injury, or loss of life. Follow the instructions included with the thermostat. Locate the thermostat approximately five (5) feet above the floor and four feet (4’) from appliance. Always mount the thermostat on an inside wall where it won’t be affected by heat or cold sources such as direct sunlight, televisions, fireplaces, hidden hot or cold water pipes, drafts, etc. The thermostat must never be installed in an adjoining room where a door can be closed between the thermostat and wall furnace. This wall furnace is equipped with a self generating control system. Never connect to a 24 volt transformer or to the household electrical system. Do not use more thermostat wire than is included with the wall furnace. Do not run thermostat wire in same stud space with vent. Conceal wire inside wall or secure to wall with insulated staples that are included . YOUR FURNACE MAY BE EQUIPPED WITH EITHER A WALL THERMOSTAT (Figure 2) OR SNAP-BULB, BUILTIN THERMOSTAT (Figure 1) CONTROL. CHECK THE CONTROL ASSEMBLY TO DETERMINE WHICH WIRING EXAMPLE TO USE. Thermocouple Gas Valve E.C.O. Fitting Manual Reset Blocked Flue Switch BULB MODELS NAT. L.P. W251F W252F W351F W352F W501F W502F FIGURE 1 Thermostat Manual Reset Blocked Pilot Flue Switch Generator Wire WALL Nut THERMOSTAT MODELS NAT. L.P. W255F W256F W355F W356F W505F W506F Gas Valve FIGURE 2 SPECIAL INSTRUCTIONS FOR REAR REGISTER KIT APPLICATION (Figures 6 and 7 line drawings of rear register opening) STEP 1.Cut hole in the back wall 8-1/4” high by 12-5/8” wide. The lower edge of the hole to be 45-3/4” above the floor plate as shown in Figure 6. STEP 2.Install frame for rear register in hole and nail frame to stud as shown in Figure 7....

Este manual também é adequado para os modelos :
Eléctrico - W251F (208.53 kb)
Eléctrico - W352F (208.53 kb)
Eléctrico - W355F (208.53 kb)
Eléctrico - W356F (208.53 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias