Log:
Assessments - 4, GPA: 4.5 ( )

Instruções de Operação Dimplex, Modelo R12/84 - 12kW

Fabricante : Dimplex
Arquivo Tamanho: 68.59 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Turning the knob clockwise increases the amount of heat stored. The setting should be adjusted from MIN to MAX to suit seasonal requirements. 2. NEON INDICATOR & 3. FAN SWITCH To obtain heat from the Electricaire Unit press the fan switch to the ON position. The fan indicator light will now glow red. If the fan is controlled by a room thermostat it will switch off automatically when the room temperature reaches the required level. The fan should be switched off before retiring at night. This function may be performed by installing a time clock. 4. BOOST SWITCH The boost switch increases the airflow delivered by the Electricaire Unit. This facility is designed to produce a rapid rise in room temperature, e.g. first thing in the morning or when you return home in cold weather. COMMISSIONING The heater should be commissioned in accordance with the installation instructions - by the installing engineer. 5. DAY ENERGY SWITCH If your Electricaire Unit is connected to the “White Meter” tariff the day energy switch operates direct acting elements. This facility extends the heat output obtainable from the Electricaire Unit by using day energy after the core has been fully discharged. To avoid unnecessary use of day rate energy the following safeguards have been built into the appliance. Day energy can only be used if: The Day Energy switch is in the ON position. The fan switch is in the ON position. The outlet air temperature has fallen below a pre-determined level. In addition ensure the input is set at MAX. MAINTENANCE MAINTENANCE ROOM ENVIRONMENTAL CONTROLS The installation may be fitted with several additional environmental controls. A room thermostat may be fitted in the room. This thermostat controls the operation of the heater fan. Adjust the setting until a comfortable environment is achieved. Note however the higher the thermostat setting the higher the running costs. Where duct work is installed individual rooms will be fitted with supply air registers. If a room is not in use the supply registers can be closed. A washable filter is fitted to ensure the warm air distributed is clean and free from dust. The filter is located in the detachable lower panel and should be washed in warm soapy water at least twice a year (see Fig. B). The filter panel can be removed by pulling the top end away from the heater and lifting out the location hooks. To maintain the appearance of the heater, wipe occasionally with a dry cloth when the heater is cool. Do not use abrasive powders or furniture polish. IMPORTANT - Do not remove any panel before isolating the heating unit from all electrical supplies. Additional maintenance should only be carried out by a trained engineer or electrician. When required contact your local electricity board or the installer. Regular inspection should take place, at least every two years. Installer Note: Please ensure that the USER INSTRUCTIONS are handed to the User when you have completed the installation if applicable, or left wi...

Este manual também é adequado para os modelos :
Eléctrico - R10/73 - 10kW (68.59 kb)
Eléctrico - R15/104 - 15kW (68.59 kb)
Eléctrico - R7/47 - 7kW (68.59 kb)
Eléctrico - R8/55 - 8kW (68.59 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias