Log:
Assessments - 3, GPA: 5 ( )

Instruções de Operação State Industries, Modelo FORCE 90TM

Fabricante : State Industries
Arquivo Tamanho: 101.29 kb
Arquivo Nome : df16f7aa-4132-4316-a0e4-8d61d3139076.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


This design provides much greater heat transfer surface than a standard straight flue tube, resulting in 90% thermal efficiency and higher hot water output than comparable 80% efficient water heaters. With 22" diameter, the 50-gallon Force 90 can be installed in less space than a 75-gallon unit and delivers greater recovery and lower operating costs. Power-Vent Design for Installation Versatility • Modular blower, with 120 volt, 60Hz electrical system (5 amps or less), 6-foot cord with standard 3-prong connector • Combined horizontal and vertical vent runs terminating through outside wall, using Schedule 40 PVC pipe as follows: -2" pipe allows vent runs up to 25 equivalent feet -3" pipe allows vent runs up to 65 equivalent feet -4" pipe allows vent runs up to 128 equivalent feet • Supplied with PVC pipe and elbows to connect heat exchanger outlet to blower, including condensate elbow and drain • PVC Vent Attenuation Assembly (VAA) supplied to help ensure extra-quiet operation Side-Mounted Taps for Recirculating Systems • Hot and cold “side taps” allow Force 90 to be used for “combination” systems for water heating plus space heating, radiant floor heating or other applications requiring a recirculating hot water loop • Plugs for recirculating taps are factory installed Intelli-Vent®* Gas Control with Silicon Nitride Hot Surface Ignitor • Premium-grade hot surface ignitor eliminates standing pilot • Electronic circuitry provides superior system diagnostic capabilities plus extremely precise temperature control • 180°F maximum temperature setting Glass Lined Tank with Two Magnesium Anode Rods • Provides superior protection against corrosion • Glass lining protects all “water side” tank surfaces plus inside of internal heat exchanger exposed to condensate Low-NOx Green Choice® Burner • Reduces NOx emissions up to 33%, complies with Southern California and Texas requirements PEXAN™ Diffuser Dip Tube • Helps reduce lime and sediment buildup, maximize hot water output • PEXAN cross-link polymer withstands long-term exposure to temperatures up to 400°F Factory-Installed Temperature and Pressure Relief Valve Maximum Hydrostatic Working Pressure: 150 psi Meets ASHRAE/IESNA 90.1-1999 • Design-certified by UL (Underwriters Laboratories) according to ANSI Z21.10.3-CSA4.3 standards governing storage-type water heaters Three-Year Limited Tank Warranty • Consult written warranty shipped with water heater or contact State for complete warranty information * Intelli-Vent is a registered trademark of the Emerson Electric Company For Additional Technical Information, PHONE 800-365-0024 State Industries, Inc. 500 Tennessee Waltz Parkway, Ashland City, TN 37015Page 1 of 2 SCGSS00806 FORCE 90™ 90% EFFICIENT Power-Vent Commercial Gas Water Heater SPECIFICATIONS MODEL NUMBER BTU INPUT PER TANK SIZE RECOVERY – GALLONS PER HOUR AT DEGREE RISE SHIPPING WEIGHT LBS.HOUR GALLONS 40°F 100°F 140°F 22°C 56°C 78°C SHE50 76NE 76,000 50 206 83 59 210 Manifold Pressure: 4.0 inches n.c. (.99 kPa); All models–Maximum Supply Pressure: 14 inches w.c. (3.48 kPa) Minimum Supply Pressure Natural Gas: 5.0 inches w.c. (1.24 kPa); Minimum Pressure must be maintained under both load and no-load (static and dynamic) conditions DIMENSIONS SHE50 76NE A B C D E F G H J K INCHES 70-5/8 68-1/4 52 21 9-1/8 12 22 8 15-3/4 27 Top inlet and outlet: 3/4" male NPT Side inlet and outlet: 3/4" female NPT Gas inlet: 1/2" NPT * INSTALL IN ACCORDANCE WITH LOCAL CODES TOP VIEW ANODE (J) (H) (K)HOT COLD FRONT VIEW (B) (G) (A) (C) (F) (D) (E) DIAMETER SIDE INLET THERMOSTAT DRAIN VALVE T & P VALVE SIDE OUTLET OUTLET (L) INLET (L) SUGGESTED SPECIFICATION (Natural or Propane) gas water heater(s) shall be State Force 90 model # SHE50 76NE, with 90% thermal efficiency, a storage capacity of 50 gallons, an input rating of 76,000 BTUs per hour, a recovery rating of 83 gallons per hour at 100.F rise and a maximum hydrostatic working pressure of 150 psi. Water heater(s) shall be of power-vent design, using 2", 3" or 4" PVC pipe for horizontal and/or vertical vent runs. Water heater(s) shall have: 1: Seamless, glass lined steel tank construction and a spiral-shaped heat exchanger placed entirely inside the tank, which shall be glass lined on the flue gas side to protect against acidic condensate. 2: An Intelli-Vent gas control system with silicon nitride hot surface ignitor. 3: A 3-year limited warranty against tank leaks. Water heater(s) shall meet or exceed ASHRAE/IESNA 90.1-1999, and be design-certified by UL (Underwriters Laboratories) according to ANSI Z21.10.3-CSA4.3 standards governing storage tank water heaters. For complete information on limited warranties, consult written warranty, or contact the State Customer Care Center, 1-800-365-0024. State Industries, Inc. reserves the right to make product changes or improvements without prior notice. Printed in U.S.A.© 2006 State Industries, Inc.SWHC-111787-10M For Additional Technical Information, PHONE 8...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias