Instruções de Operação Empire Comfort Systems, Modelo DV25IN33L

Fabricante : Empire Comfort Systems
Arquivo Tamanho: 2.79 mb
Arquivo Nome : 55c4e3c4-e165-4f44-9a6d-bae8bafef3a4.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


WARNING: THE EXHAUST PIPE MUST ONLY BE CONNECTED TO THE EXHAUST STARTING COLLAR OF THE UNIT AND TO THE EXHAUST COLLAR OF THE TERMINATION CAP. THE INLET AIR PIPE MUST ONLY BE CONNECTED TO THE INLET AIR STARTING COLLAR OF THE UNIT AND TO THE INLET AIR COLLAR OF THE TERMINATION CAP. BOTH THE INLET VENT AND THE FLUE VENT MUST BE CONNECTED FROM THE INSERT TO THE VENT TERMINATION CAP. NOTE: The minimum vertical vent rise is 12 feet and the maximum vertical vent rise is 35 feet. These dimensions are measured from the starting collars of the unit to the end of the last section of vent pipe. See Figure 8. NOTE: The damper of the masonry chimney may need to be removed to allow installation of the flexible-vent pipe. When installing into a zero clearance, factory built wood-burning fireplaces, the use of the DVKI Round Vertical Termination Kit should allow you to mount the vent adaptor and cap to the exposed round chimney pipe easily. Connecting the Vent Pipe Caution: Sharp edges. Always use gloves when installing. Install the 3-inch flexible vent pipes down through the chimney. Attach the pipe-to-cap adaptor to the termination cap and the top of the flexible vent pipe, then install the cap to the top of the chimney. Remove the vent slide plate assembly from the top of the insert. See Figure 7. Trim off excess venting then attach and secure the bottom ends of the flex pipes to the starting collars with the adjustable band clamps provided. Slide the gas insert into place, and position any excess flex vent pipe back up into the chimney. Begin installation of the insert into the fireplace opening. Align the vent slide plate assembly with the guides located on top of the insert. Work the insert inch by inch into the fireplace cavity as you pull forward on the vent slide plate assembly. Do not use excessive force on the vent slide plate. Once the vent slide plate is close to seating, install the vent bolt through the center hole of the insert top flange, and into the vent slide plate nut. Using a wrench or socket, tighten the bolt until the vent slide plate is seated forward completely. Positioning, Leveling, and Securing Insert 1. Place the insert into position. Note: The front flanges of the insert (without surround panels) should be set at approximately 1”(inch) in front of the face of the fireplace. 2. Level the insert from side to side and front to back. 3. If necessary, use the leveling bolts included in the instruction pack. Screw the legs into the nuts installed in the bottom of the insert. Turn legs in until insert is level. CAUTION: TO AVOID DOWNDRAFTS AND/OR COLD AIR PROBLEMS, IT IS RECOMMENDED TO SEAL OFF THE AREA BETWEEN THE TERMINATION CAP AND THE TOP OF THE SOLID-FUEL CHIMNEY OPENING INTO WHICH THE VENT CAP HAS BEEN INSTALLED. Figure 7 Page 12 23015-3-0707 Figure 8 VENTING AND INSTALLATION RECTANGULAR TERMINATION CAP (DVVK3FV KIT) VENT CLAMPS INTAKE VENT FLUE EXHAUST VENT OPTIONAL ON/OFF SWITCH LOCATION 10’ MINIMUM 35’ MAXIMUM VENT CLAMPS NOTE: LONG EXTENSION TUBE FOR INLET VENT CONNECTION. RETAINER SCREWS MAY BE INSTALLED THROUGH THE VENT CLAMPS TO ENSURE POSITIVE SECUREMENT OF VENTING. SCREWS ADDED THROUGH VENT CLAMPS TO RETAIN VENTING TO COLLARS RECOMMENDED. USE HIGH TEMP SEALANT ON VENT CONNECTIONS USE HIGH TEMP SEALANT ON VENT CONNECTIONS ROUND TERMINATION CAP (DVKI KIT) ROUND CO-LINEAR TO CO-AXIAL ADAPTOR BLOWER ACCESS COVER PLATE BLOWER POWER CORD OPTIONAL LOW VOLTAGE WIRES OPTIONAL ON/OFF SWITCH LOCATION VERTICAL TERMINATION Determining Minimum Vent Height Above the Roof. WARNING: Major U.S. building codes specify minimum chimney and/or vent height above the roof top. These minimum heights are necessary in the interest of safety. These specifications are summarized in Figure 9. ROOF PITCH H (Min.) Flat to 6/12 12" (305 mm) 6/12 to 7/12 15" (381 mm) Over 7/12 to 8/12 18" (457 mm) Over 8/12 to 16/12 24" (610 mm) Over 16/12 to 21/12 36" (914 mm) Vertical Through the Roof Applications The Gas Fireplace Insert has been approved for: a) Vertical installations up to 35 feet in height (top of insert to cap). b) Two sets of 45 degree elbow offsets (bends in flexvent) within the vertical installation. From 0 to a maximum of 8 ft. of vent pipe can be used between elbows. c) Wall straps must be used to support offset pipe every 4'. This application will require that you first determine the roof pitch and use the appropriate venting components. General Maintenance Conduct an inspection of the venting system semi-annually. Recommended areas to inspect are as follows: 1. Check areas of the venting system which are exposed to the elements for corrosion. These will appear as rust spots or streaks and, in extreme cases, holes. These components should immediately be replaced. 2. Remove the cap and shine a flashlight down the vent. Remove any bird nests or other foreign material. 3. Check for evidence of excessive condensate, such as water droplets forming in the flex venting and subsequently dripping out at joints or s...

Este manual também é adequado para os modelos :
Eléctrico - DV25IN33L (2.79 mb)
Eléctrico - DV33IN33L (2.79 mb)
Eléctrico - DV35IN33L (2.79 mb)
Eléctrico - DV33IN33L (2.79 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias