Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação Empire Comfort Systems, Modelo DVP42FP

Fabricante : Empire Comfort Systems
Arquivo Tamanho: 4.86 mb
Arquivo Nome : 4e1880de-91ce-7514-dd6f-969c96c78167.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Vertical dimensions are based on centerline to centerline of pipe. Horizontal dimensions are based on centerline of pipe to end of termination. Firestop at Ceiling Level Firestop at Ceiling Level VENTING FIREPLACE - TOP (continued) 21759-6-0608 Page 17 MAXIMUM HORIZONTAL RUN WITH NO VERTICAL RISE AND 90° ELBOW MAXIMUM HORIZONTAL RUN WITH MINIMUM VERTICAL RISE AND 90° ELBOW minimum Figure 25 Figure 24 MINIMUM HOLE LOCATION DIMENSIONS FOR THROUGH THE WALL HORIZONTAL INSTALLATIONS WITH 90 DEGREE ELBOW OFF TOP OF FIREPLACE Positioning the Fireplace Determine the exact position of the appliance so the direct vent termination will be centered (if possible) between two (2) studs. This will avoid any extra framing. All vent kit pipes should be assembled on the unit after the unit is moved into the final position. Cutting the Hole (Figures 23) After the fireplace has been positioned in its permanent location, the hole through the exterior wall of the house can be cut. This hole must be 12" (305mm) high x 10" (254mm) wide with its center line determined by the amount of vertical rise and horizontal run of the termination. See Figure 23. When locating the hole it must be noted that the bottom of the cap must be 12" (305mm) above the ground level, and top of the cap must be no less than 18" (457mm) below a combustible projection, and no closer than 9" (229mm) to any wall running parallel to vent termination. See Figure 24. A CENTER OF ELBOW STRAIGHT OUT (MINIMUM) 2 30 FIREPLACE SERIES HARD ELBOW DIMENSIONS "A" "B" "C" DVP42FP 43-1/2" (1105mm) 5" (127mm) 7" (178mm) DVP48FP 43-1/2" (1105mm) 5" (127mm) 7" (178mm) FIREPLACE SERIES FLEX PIPE 90 DEGREE BEND "A" "B" "C" DVP42FP 46" (1143mm) 5" (127mm) 7" (178mm) DVP48FP 46" (1143mm) 5" (127mm) 7" (178mm) Figure 23 EXAMPLES - TOP VENT RUN 24” 24” MINIMUM CLEARANCE TO COMBUSTIBLES Figure 27 Figure 26 Figure 28 Page 18 21759-6-0608 21759-6-0608 Page 19 VENTING EXAMPLES WHEN USING DVA47 ADAPTOR Vertically Off Top of Fireplace Only Figure 29 Figure 30 Figure 31 DVVK-4FV DIRECT VENT TERMINATION KIT Installation Instructions This termination kit can only be used with Empire Comfort Systems direct vent fireplaces listed for use with DVVK-4FV Vertical Flex Vent Kit. Please review the instructions packaged with your fireplace and verify the fireplace model number. Check that this flex vent system is listed for use with your fireplace model prior to starting the installation. This vent kit may be installed as an OEM installation in a manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer’s instructions and the manufactured home construction and safety standard, Title 24 CFR, Part 3280 or Standard for Installation in Mobile Homes, CAN/CSA Z240 MH. CAUTION All Fireplaces listed for use with the DVVK-4FV will operate safely when installed in accordance with this instruction manual. Read all instructions before starting installation, then follow these instructions carefully to maximize fireplace performance and safety. Report damaged parts to your dealer. WARNING Any common venting of the gas appliance using the DV vent kit with other gas appliances is not allowed. Do not connect this appliance to a chimney flue servicing a separate solid fuel-burning appliance. WARNING Failure to follow these instructions may create a possible fire hazard and will void the warranty. WARNING Always maintain minimum clearances around vent systems. The minimum clearance to combustibles for horizontal runs of vent pipe is 3 inches from the top, and 1 inch from the sides and bottom of the vent system. Do not pack the open air spaces around the fireplace or flue with insulation or other materials. Any horizontal run must have a 1/4” rise for every one (1) foot of run towards the vent termination. The vent above the roof must terminate vertically. WARNING Contact your Local Building and Fire Officials about restrictions and installation inspections in your area. IMPORTANT SAFETY INFORMATION • The vertical termination cap MUST be vented directly to the outside. The termination kit MUST NEVER be connected to a chimney flue(s) servicing a separate solid-fuel burning appliance or any other appliances. • Termination cap MUST NOT be mounted horizontally. • The flexible vent pipe cannot be intermingled with any of the rigid vent pipe section(s). DO NOT connect two sections of flexible vent pipe together to achieve a longer length without the use of approved connectors. • The installation must conform with local codes or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 (in the United States) or with the current installation code CAN/CGA B149 (in Canada). • Only Direct Vent fireplaces approved for use with Empire Comfort Systems, Inc. DVVK-4FV termination kit shall be used. See PARTS LIST/ILLUSTRATIONS section for vent component identification. • Horizontal vent runs must be supported every 2 feet using wall straps. Vertical runs must be supported e...

Este manual também é adequado para os modelos :
Eléctrico - DVP42FP (4.86 mb)
Eléctrico - P)-2 (4.86 mb)
Eléctrico - P)-2 (4.86 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias