Log:
Assessments - 4, GPA: 4.3 ( )

Instruções de Operação Gas-Fired Products, Modelo Tube Series PTS

Fabricante : Gas-Fired Products
Arquivo Tamanho: 1.4 mb
Arquivo Nome : PTS-PTU-Series-Spec-Sheet(S45600)-Rev-8-08.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Space-Rayinfraredheatersheatlikethesunbytransferringradiantheatenergydirectlytotheareastobeheated.Radiantenergyisabsorbedbyconcretefloors,objectsandpeople,andre-radiatedtowarmthesurroundingarea.Thisprincipleissimilartothesun’sradiantheatenergyheatingtheEarthbutnottheupperatmosphere.Thisheatingtech- nologycreatesacomfortzoneatfloorlevel,notattheceiling,andismuchmoreefficientthanconventionalforcedairheatingsystems. AhighlyradiantefficientSpace-Rayinfraredheatingsystemcannormallysaveabuild- ingowner30%to50%inannualfuelcostswhencomparedtoforcedairheatingsys- tems.Infact,someSpace-Raycustomersreportfuelsavingsashighas70%withapaybackoflessthanoneyear.WithaSpace-Raysystem,yourinvestmentpaybackac- cruesnotonlyfromreducedenergycosts,butfromreducedmaintenancecosts,too. Sowhenyouthinkindustrialheating,thinkSpace-Ray.Callusat1-800-438-4936forthenameofourrepresentativenearestyou. InfraredGasHeatersForIndustrySince1949LOWINTENSITYPTS/PTUSeriesTubeHeatersSPACE-RAY®…ATRUSTEDNAMEININFRAREDHEATINGHEATINGTECHNOLOGYFORTHENEXTMILLENNIUM30%-50%FUELSAVINGSSPECIFICATIONSPTUSeriesPositivePressurePTSSeriesSingleStageInputTwoStageInput AtSpace-Ray,industrialcomfortheatingisachallengewetakeseriously.Wehavebeenmanufacturinggas-firedinfraredheatingsystemssince1949.Thequalityandperformanceofourheatersarebasedonover50yearsoffieldexperienceandex- posuretoawidevarietyofindustrialheatingproblems.Ourreputationisbuiltuponasolidtrackrecordforprovidingradiantefficient,easy-to-installandhighqualityin- fraredheatingequipment. Space-Rayinfraredtubeheatersareidealforcompletebuildingheatorevenspotheat- ingneeds.Thebestapplicationsinclude:manufacturingplants,warehouses,autodeal- erships,aircrafthangars,loadingdocks,weldshops,truckorautoserviceareas,carwashes,firestations,greenhouses,gymnasiums,garages,machineshops,tenniscourts,swimmingpools,maintenanceshops,farmbuildingsandmanymanymore. Space-Rayinfraredheatersheatlikethesunbytransferringradiantheatenergydirectlytotheareastobeheated.Radiantenergyisabsorbedbyconcretefloors,objectsandpeople,andre-radiatedtowarmthesurroundingarea.Thisprincipleissimilartothesun’sradiantheatenergyheatingtheEarthbutnottheupperatmosphere.Thisheatingtech- nologycreatesacomfortzoneatfloorlevel,notattheceiling,andismuchmoreefficientthanconventionalforcedairheatingsystems. AhighlyradiantefficientSpace-Rayinfraredheatingsystemcannormallysaveabuild- ingowner30%to50%inannualfuelcostswhencomparedtoforcedairheatingsys- tems.Infact,someSpace-Raycustomersreportfuelsavingsashighas70%withapaybackoflessthanoneyear.WithaSpace-Raysystem,yourinvestmentpaybackac- cruesnotonlyfromreducedenergycosts,butfromreducedmaintenancecosts,too. Sowhenyouthinkindustrialheating,thinkSpace-Ray.Callusat1-800-438-4936forthenameofourrepresentativenearestyou. InfraredGasHeatersForIndustrySince1949LOWINTENSITYPTS/PTUSeriesTubeHeatersSPACE-RAY®…ATRUSTEDNAMEININFRAREDHEATINGHEATINGTECHNOLOGYFORTHENEXTMILLENNIUM30%-50%FUELSAVINGSSPECIFICATIONSPTUSeriesPositivePressurePTSSeriesSingleStageInputTwoStageInput MODEL SINGLE STAGE BTU/HR INPUT TWO STAGE TOTAL EMITTER TUBE LENGTH* 30 FT 40 FT 50 FT 60 FT 70 FT Btu/hr High Input Btu/hr Low Input PTS/U 125 125,000 125,000 80,000 X X X PTS/U 150 150,000 150,000 100,000 X X X PTS/U 175 175,000 175,000 110,000 X X X PTS/U 200 200,000 200,000 125,000 X X X MODELPTS/U4040,00040,00025,000PTS/U5050,00050,00030,000PTS/U7575,00075,00050,000PTS/U100100,000100,00065,000MODELSELECTIONSGENERALFEATURES•8differentBtu/hrsizesandmorethan100differentconfigurationstocustomdesignyourinfraredheatingsystem•SingleStageorTwoStageInputControls•CSAdesigncertified•Ventedorindirectventedoperation•Sidewallorthrough-the-roofventing•NaturalandpropanegasmodelsPUSHTHROUGHSYSTEM(PositivePressure) •Productsofcombustionarepushedthroughthecombustionchamber•TubeIntegritySafetySystem(TISS) •Nodrafthoods,totallyenclosedcombustionchamber•Blowermotortotallyenclosedintheburnerbox. Idealforapplicationswhereminimalnoise(lessthan60dB)isdesired•Heavydutypermanentlylubricated,ballbearingblowermotorformaintenance-freeoperationBURNERSYSTEM•Heavy-dutycastironburner•10-yearlimitedwarrantyonburner•Insideoroutsideairforcombustion•Upto40ft.outsidecombustionairductcapability•Standard4”combustionaircollar•Reliabledirectsparkignitionsystemand100% gasshut-offsafetycontrol•Pre-purgeandpost-purgefunction•State-of-the-artstepopeningredundantcombinationgasvalveforquietignitionandaddedsafety•Diaphragmairswitchforproofofventingbeforegasflowandignition•Diagnosticmonitoringlightsystem•Burnerinspectionsightglass•Linevoltageor24VthermostatconnectionTOTALEMITTERTUBELENGTH* 10FT**20FT30FT40FTGASTYPEPTS/PTUSERIESFEATURESNATURAL3.5”W.C.5”W.C*14”W.C. PROPANE10”W.C.11”W.C.*14”W.C. BURNERPRESSUREVOLTAGEAMPSIGNITIONTYPEMINMAX120VAC60HZ1.8DIRECTSPARKSUPPLYPRESSUREFLUECONNECTIONOUTSIDECOMBUSTIONAIRCONNECTION4”Round4”RoundSINGLESTAGEBTU/HRINPUTBtu/hrHighInputBtu/hrLowInputTWOSTAGEXXXXXXXXCONTROLSUFFIXN5/L5N7/L7TYPEOFGASNatural/PropaneNatural/PropaneCONTROLOPTIONDESCRIPTIONSingleStageGasValve-SingleSta...

Este manual também é adequado para os modelos :
Eléctrico - Tube Series PTU (1.4 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias