Facilidade de uso


The HRVB provides efficient and cost-effective heat recovery during the heating season when needed most. As temperatures drop below 23°F (–5°C), indoor air is recirculated periodically through the heat exchanger core to prevent frost from forming. Competitors’ methods of supplementary electric defrost waste energy. Unlike rotary wheel heat exchangers which mix air streams, these cross flow or counterflow heat exchangers ensure that there is no mixing of the stale air stream with the fresh outdoor air stream. A filter installed on the incoming outdoor air stream removes large airborne particles from the intake air stream before they enter the heat exchanger and reduces the maintenance required. The units’ acoustically engineered design makes them the quietest on the market and ensures that comfort is felt, not heard. Unlatching 2 suitcase style latches allows easy removal of the filters and core for cleaning. FEATURES • Energy saving defrost cycle • Cross flow, counterflow heat exchangers • Two filters on incoming outdoor air stream to protect the HRV core • Acoustical design • No-tools maintenance • Polypropylene heat exchanger core HRVBBSVC HRVBBLHU HRVBBLVU Model number nomenclature HRV BB LHU 1 150 Maximum Capacity (CFM) 150 CFM 200 CFM 250 CFM 330 CFM Electrical Supply: 1 — 115 volts Descriptor: LHU — Large Horizontal Unit SVU — Small Vertical Unit LVU — Large Vertical Unit Brand: Bryant Equipment Type: Heat Recovery Ventilator TESTED/CERTIFIED HOME VENTILATING INSTITUTEO DIVISION OF AMCA Climate Map for Energy and Heat Recovery Ventilators ERV Recommended w/HRV or ERV Wall Control ERV Recommended HRV Recommended Honolulu Sacramento Salt Lake City Boise Salem Vancouver Helena Edmonton Calgary Regina Winnipeg Bismark Topeka Denver Oklahoma City Austin Baton Rouge Orlando Atlanta Columbia Raleigh Washington D.C. Nashville IndianapolisSpringfield ChicagoDes Moines Minneapolis Green Bay Milwaukee Detroit Madison Harrisburg Hartford Boston Syracuse Montreal Ottawa Timmins A00099 —2— Controls and accessories part no. nomenclature K V B CN01 01 BAU CONTROL DESCRIPTION BAU — Bryant Automatic Control BBS — Bryant Basic Control BST — Bryant Standard Control ACCESSORY DESCRIPTION 6FM — 6 in. Flowmeters (2) 7FM — 7 in. Flowmeters (2) 8FM — 8 in. Flowmeters (2) EXH — Exhaust Hood HOD — Intake Hood KIT — Balancing Kit FIR — Interlock Relay TIMER DESCRIPTION 20C — 20-Minute Timer Kit Carrier 60M — 60 Minute Adjustable Timer Kit FILTER DESCRIPTION 112 116 123 145 713 810 812 916 — 11-1/2 x 12-3/4 — 11-7/8 x 16-5/8 — 12-15/16 x 13-1/2 — 14-3/8 x 15-1/2 — 7-13/16 x 13-1/2 — 8-1/8 x 10-3/4 — 8-7/8 x 12-3/4 — 9 x 16-5/8 01 — Single Pack 01 — Part Number AC — Accessory CN — Control FL — Filter Media TM — Timer A — Original Series B — Second Series V — Heat Recovery Ventilator (HRV) K — Accessory Kit ACCESSORIES Kit Number Description Where Used KVBCN0101CBS Basic HRV Control Used with all HRVs KVBCN0101CST Standard HRV Control Used with all HRVs KVBCN0101CAU Automatic HRV Control HRVBLSVU, HRVBBLVU KVAAC0101FIR Interlock Relay When combining an HRV with a Furnace or Fan Coil KVATM010120C 20 Minute Push Button Timer Used with all HRVs when 20 minute manual operation is required KVATM010160M 60 Minute Timer Used with all HRVs, time is adjustable between 10 and 60 minutes KVAAC0101HOD Exterior Intake and Exhaust Hood 2 Required KVAAC0101KIT Start up Balancing Kit Start up Balancing Kit, includes (2) 6 in. Flow Meter Collars & Magnehelic Gage KVAAC01016FM 6 in. Flow Meter Collar At start up, when 6 in. duct work is connected to HRV KVAAC01017FM 7 in. Flow Meter Collar At start up, when 7 in. duct work is connected to HRV KVAAC01018FM 8 in. Flow Meter Collar At start up, when 8 in. duct work is connected to HRV KVAFK0101150 Internal Filter Used with HRVBBLHU 1150 Unit 11 3/4 x 12 7/8 x 3/4 (2) KVAFK0201200 Internal Filter Used with HRVBBLHU 1250 Unit 11 3/4 x 16 3/4 x 3/4 (2) KVAFL0101713 Internal Filter Used with HRVBBSVU 1150 Unit 7 13/16 x 13 1/2 (2) KVAFL0101123 Internal Filter Used with HRVBBSVU 1200 Unit 12 15/16 x 13 1/2 (2) KVAFL0101123 Internal Filter Used with HRVBBLVU 1200 Unit 12 15/16 x 13 1/2 (2) KVAFL0101145 Internal Filter Used with HRVBBLVU 1200 Unit 14 3/8 x 15 1/2 KVAFL0101810 Internal Filter Used with HRVBBLVU 1330 Unit 8 1/8 x 10 3/4 (1) KVAFL0101145 Internal Filter Used with HRVBBLVU 1330 Unit 14 3/8 x 15 1/2 (1) KVAFL0101810 Internal Filter Used with HRVBBLVU 1200 Unit 8 1/8 x 10 3/4 (1) —3— CONTROL FEATURES Basic Control: Allows the user to manually set fan speed to low or high as required to maximize comfort. Standard Control: Offers automatic dehumidistat control and the option to select continuous or intermittent fan operation. Setting the wall control to low will activate the continuous mode. Automatic Control: In addition to the features found with standard control, this package offers a recirculation mode. These controls may only be used to operate stand-alone units with the defrost option which ena...

Este manual também é adequado para os modelos :
Eléctrico - HRVBBLVU (160.59 kb)
Eléctrico - HRVBBSVC (160.59 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias