Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Hearth and Home Technologies, Modelo SL-350TRSI-AUE

Fabricante : Hearth and Home Technologies
Arquivo Tamanho: 2.11 mb
Arquivo Nome : a360d0be-ee0e-4ae6-afd4-d9c3db330ccd.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Adjust or replace inlet regulatorif necessary. C. Valve. Replace valve and thermocouple interrupter. 7. 3 short beeps while the motor turns. A. Batteries are low. Replace batteries - quality alkaline recommended. WARNING: Creating anelectrical short between the batteries/battery box and metal parts of theappliance may render the receiver inoperable. 8. Pilot flame lights but there isno main gas flow. A. Manual override know (ifequipped) is in MANposition. Turn Manual override know to ON position. B. Valve turned don to pilot flow. Turn flame to high fire by pressing up button on remote handset. C. Low inlet pressure to valve. Confirm sufficient inlet pressure to the valve. Adjust or replace inlet regulatorif necessary. D. Valve. Replace valve. 9. Pilot sparks, but pilot will notlight. A. Correct gas supply. Verify that incoming gas line ball valve is “open”. Verify that inlet pressurereading is within acceptable limits, inlet pressure must not exceed 50 mbar. B. Ignitor gap is too large. Verify that spark gap from ignitor to pilot hood is .43 cm. C. Module is not grounded. Verify module is securely grounded to metal chassis of fireplace. 10. Glass soots. A. Flame impingement on logs. Adjust the log set so that the flame does not impinge on it. B. Improper venturi setting. Adjust the air shutter at the base of the burner. C. Debris around venturi. Inspect the opening at the base of the burner. It is imperative that NOmaterial be placed in this opening. 11. Flame burns blue and lifts off burner. A. Insufficient oxygen beingsupplied. 1. Check to make sure flue cap is installed properly and free of debris. Make sure that flue system points are tight and have no leaks. 2. Check to make sure that no material has been placed in the opening atthe burner base or in the area of the air holes in the center of the base panbeneath the burner. 3. Be sure glass is tighened properly on unit, particularly on top corners. Heat & Glo • SL-350TRSI-AUE • 2089-902 Rev. B • 6/06 35 Heat & Glo • SL-350TRSI-AUE • 2089-902 Rev. B • 6/06 (NG, LP) Exploded Parts Diagram Service Parts SL-350TRSI-AUE Beginning Manufacturing Date: 6/06 Ending Manufacturing Date: ______ 22 Log set assembly 2 13 4 10 16 15 14 12 7 8 11 21 32 31 23 25 27 24 26 28 18 4.0 REPLACEMENT PARTS 1 5 19 6 17 33 20 9 3 30 29 34 35 .. SL-350TRSI-AUE Service Parts List IMPORTANT: When ordering, supply serial and model numbers to ensure correct service parts. ITEM PARTS PART NUMBER 1 Valve NG 2098-134 Valve LP 2098-135 2 Orifice NG 582-844 Orifice LP 582-055 3 18 Iin Flex Tube Assembly 530-302A 4 Burner Assembly NG 2089-010 Burner Assembly LP 2089-012 5 Ignition Cable 2098-147 6 Hood SRV540-174 7 Glass Door Assembly GLA-350TRS 8 Dress Guard 2033-020 9 Module, Maxitrol 2098-142 10 Lower Door 2033-021 11 Grate 2033-013 12 Base Pan 2033-105 13 Blower Assembly 240V 100-505A 14 Junction Box, 240V 2078-025 15 Power Cord, 240V 546-251A 16 Pilot Assembly NG 2098-050 Pilot Assembly LP 2098-051 17 Switch Assembly 2098-145 18 Interior Top Heat Shield 2089-109 19 12 inch Flex 2078-022 20 Rheostat 491-510A 21 Switch Sensor 046-530 22 Log Set Assembly LOGS-350CE-D 23 Log #1 SRV327-701 24 Log #2 SRV2033-701 25 Log #3 SRV705-703 26 Log #4 SRV530-716 27 Log #5 SRV438-724 28 Log #6 SRV540-704 29 6 Volt Transformer 2098-145 30 Burner Neck Gasket 2045-407 31 Valve Plate Gasket 530-431 32 Pilot Bracket 2089-104 33 Valve Bracket 2098-120 34 Control Cable 2098-143 35 Rheostat Knob 100-512 Mesh Assembly 540-301A Exhaust Resistor 2089-299 Accesssories WSK-DLX-CE WSK-21 Conversion Kit NG NGK-350I-AUE Conversion Kit LP LPK-350I-AUE Heat & Glo • SL-350TRSI-AUE • 2089-902 Rev. B • 6/06 LIMITED 10 YEAR WARRANTY HEAT & GLO, a brand of Hearth & Home Technologies Inc. In order to presumptively establish the dates to which your HEAT & GLO Limited 10 Year Warranty runs, you must mail the completed warranty card to HEAT & GLO, a brand of Hearth & Home Technologies Inc., 20802 Kensington Boulevard, Lakeville, MN 55044, within 60 days of the date of fireplace installation. If you fail to do so, you may be required to prove the date of installation before warranty work can be performed. The warranty exclusions and limitations of liability are effective upon installation of the fireplace. Subject to the conditions set forth herein, HEAT & GLO, a brand of Hearth & Home Technologies Inc. ("HEAT & GLO") extends the following warranty with respect to HEAT & GLO, a brand of Hearth & Home Technologies Inc.. If HEAT & GLO is reasonably satisfied that any part or portion of the fireplace covered by this Limited Warranty is defective in material or workmanship under normal use and service as described in the Operating Instructions, HEAT & GLO will take the following actions: 1. If the defect is reported during the first year from the date of installation (stainless steel burners and fiber logs are covered for 3 years), HEAT & GLO will replace or repair the defective components at its sole expense. The decision whether...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias