Instruções de Operação Chromalox, Modelo DS-50600

Fabricante : Chromalox
Arquivo Tamanho: 318.46 kb
Arquivo Nome : IM-PG436.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Table 1 Kit Model Used with Heater Model Kit Function Installation Instructions Wiring Diagram DS-50600 Fixed STAR-06A and STAR-14A Adds Integral Disconnect Switch See Page 2 Fig. 1 DS-50600 Portable STAR-06A and STAR-14A Adds Integral Disconnect Switch See Page 3 Fig. 1 STAR-GF All Fixed STAR Adds Wall Mounted Ground Fault Sensor See Page 4 Fig. 2 STAR-TIP Portable STAR-06A and STAR-14A Adds Tip Over Shut Down See Page 5 Fig. 3 STAR-TG Portable STAR-06A and STAR-14A Adds Tip Over Shut Down with Ground Fault Sensor See Pages 5 and 6 Fig. 4 GENERAL To use this instruction sheet from Table 1 select the Installation Instructions by matching the Kit Model to the Heater Model. If a match does not exist consult Factory. The kits are add-on options to STAR Radiant Heaters. The installation and renewal parts identification for the heater is cov- ered in the instruction sheet provided with the heater. SAVE BOTH COPIES OF THE INSTRUCTION SHEET. ELECTRIC SHOCK HAZARD. Disconnect all power to heater before installing or servicing kit(s). Failure to do so could result in personal injury or property damage. Kit(s) must be installed by a qualified person in accordance with the National Electrical Code, NFPA 70. Always check to make certain the voltage rating of the kit matches the voltage rating of the heater (See Nameplates). Model DS50600 STAR-GF Model STAR-TIP STAR-TG (Supersedes PG436-1)PG436-2VTS161-304901-004JUNE, 20104DATESALESREFERENCEDIVISIONSECTIONChromalox® DS-50600, STAR-GF, STAR-TIP and STAR-TG Kits For Adding Optional Kits to STAR Radiant Heaters © 2008 Chromalox, Inc. Table 1 Kit Model Used with Heater Model Kit Function Installation Instructions Wiring Diagram DS-50600 Fixed STAR-06A and STAR-14A Adds Integral Disconnect Switch See Page 2 Fig. 1 DS-50600 Portable STAR-06A and STAR-14A Adds Integral Disconnect Switch See Page 3 Fig. 1 STAR-GF All Fixed STAR Adds Wall Mounted Ground Fault Sensor See Page 4 Fig. 2 STAR-TIP Portable STAR-06A and STAR-14A Adds Tip Over Shut Down See Page 5 Fig. 3 STAR-TG Portable STAR-06A and STAR-14A Adds Tip Over Shut Down with Ground Fault Sensor See Pages 5 and 6 Fig. 4 GENERAL To use this instruction sheet from Table 1 select the Installation Instructions by matching the Kit Model to the Heater Model. If a match does not exist consult Factory. The kits are add-on options to STAR Radiant Heaters. The installation and renewal parts identification for the heater is cov- ered in the instruction sheet provided with the heater. SAVE BOTH COPIES OF THE INSTRUCTION SHEET. ELECTRIC SHOCK HAZARD. Disconnect all power to heater before installing or servicing kit(s). Failure to do so could result in personal injury or property damage. Kit(s) must be installed by a qualified person in accordance with the National Electrical Code, NFPA 70. Always check to make certain the voltage rating of the kit matches the voltage rating of the heater (See Nameplates). Model DS50600 STAR-GF Model STAR-TIP STAR-TG INSTALLATION INSTRUCTIONS Cover(Step 4) 3 Pole Terminal Block w/Ground(Step 8) Opening for 1" Conduit Fitting(Step 8) 3 Pole Disconnect SwitchOn-Off HandleChase Nipple and Gasket(Step 5) Cover(Step 3) Drawing shows 6 kW heater. 13.5 kW heater steps are identical. INSTRUCTIONS FOR INSTALLING DISCONNECT SWITCH ON 6 AND 13.5 KW FIXED RADIANT HEATERS 1. Addition of the disconnect switch assy must be done by a qualified electrician. 2. The disconnect switch kit includes the following parts. Verify that all parts are included, if not, contact the Chromalox Service Dept. (1)Disconnect Switch Assy (2)Mounting Bracket (Not Used) (3)Hardware Kit: (Not Used) Two 3/8” Lockwashers Two 3/8” Nuts One Self Tapping Screw One Gasket for Cord Fitting (Supplied Separately) 3. Remove the screws in the heater terminal box. Remove cover. 4. Remove cover from disconnect switch assy using same method as Step3. 5. Remove Chase nipple and gasket from opening end of disconnect switch assy. Slide Chase nipple through hole in heater terminal box and then gasket over threads. 6. Thread Chase nipple into threaded coupling. Wrench tighten nipple. 7. Uncoil three (3) leads marked “1”, “2”, and “3” located in disconnect switch housing. Thread these three (3) leads through the nipple. Attach leads to the terminals indicated on the heater wiring label located on the cover of the heater. If using for single phase, cap off lead marked “3”. 8. Attach conduit to the opening in the disconnect switch housing. Connect leads to terminal block. 9. Inspect all wiring to make sure all connections are tight, adequate electrical clearances exist, and all electrical practices are met. 10.Install both covers. 2 INSTALLATION INSTRUCTIONS Self Tapping Screw(Step 8) On-Off HandleCover(Step 5)3 Pole Disconnect Switch3 Pole Terminal Block w/Ground (Step 11) Chase Nipple and Gasket(Step 6) Cover(Step 3)Mounting Bracket(Step 4) 3/8" Lockwasher and Nut(Step 4) Opening for 1" Cord Fitting(Step 11) Drawing shows 6 kW heater. 13.5 kW heater steps are id...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias