Instruções de Operação Eagle Electronics, Modelo FishElite, SeaCharter 480, 480DF

Fabricante : Eagle Electronics
Arquivo Tamanho: 5.07 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


The depth indicators now accurately show the depth of water beneath the keel. NOTE: If knowing the exact depth of water beneath the keel is less important, you can calibrate the depth indicators so that they show the actual wa 76 ter depth from surface to bottom. To do this, first measure the distance from the face of the transducer up to the surface (the water line on the boat). In this example, we will use 1.5 feet. This will be entered as a positive 1.5 feet, which makes the depth indicators perform as if the transducer's higher in the water than it really is. ter depth from surface to bottom. To do this, first measure the distance from the face of the transducer up to the surface (the water line on the boat). In this example, we will use 1.5 feet. This will be entered as a positive 1.5 feet, which makes the depth indicators perform as if the transducer's higher in the water than it really is. Press MENU|MENU|v to SET KEEL OFFSET|ENT. 2. The Keel Offset dialog box appears with a plus (+) sign at the front of the box. 3. Press > to the first number, then press ^ to change the number to 1. 4. Press > to the second number, them press ^ to change the number to 5, then press EXIT. The depth indicators now accurately show the water depth from surface to bottom. Sensitivity & Auto Sensitivity The sensitivity controls the ability of the unit to pick up echoes. Sensitivity can be adjusted, because water conditions vary greatly. A low sensitivity level (from zero to 50 percent) excludes much of the bottom information, fish signals, and other target information. High sensitivity levels let you see this detail, but it can also clutter the screen with many undesired signals. Typically, the best sensitivity level shows a good solid bottom signal with Grayline and some surface clutter. Automatic Sensitivity The default sensitivity mode is automatic. The unit bases the sensitivity level on water depth and conditions. When the unit is in the automatic mode, sensitivity is automatically adjusted to keep a solid bottom signal displayed, plus a little more power. This gives it the capability to show fish and other detail. However, situations occur when it becomes necessary to increase or decrease the sensitivity. This typically happens when you wish to see more detail, so an increase in sensitivity is indicated. Or, wave action and boat wakes can create enough tiny air bubbles to clutter much of the water column. In that case, a decrease in sensitivity is indicated to reduce some of the clutter. The control bar used to adjust sensitivity up or down is the same whether the unit is in the automatic or manual mode. In automatic you can adjust sensitivity up to 100 percent but the unit will limit your minimum setting. In auto, the unit will continue to make small adjustments, allowing for the setting you selected. 77 In manual mode, you have complete control over sensitivity, with the ability to set it anywhere from zero to 100 percent. Once you select a level in manual, the unit will continue to use that exact sensitivity setting until you change it or revert to auto mode. In manual mode, you have complete control over sensitivity, with the ability to set it anywhere from zero to 100 percent. Once you select a level in manual, the unit will continue to use that exact sensitivity setting until you change it or revert to auto mode. 1. Press MENU|ENT. 2. The Sensitivity Control Bar appears. Press v to decrease sensitivity; press ^ to increase sensitivity. When it's set at the desired level, press EXIT. (When you reach the maximum or minimum limit, a tone sounds.) At left, Sonar Menu with Sensitivity command selected. At right, the Sensitivity Control Bar. To adjust sensitivity in manual mode: 1. First, turn off Auto Sensitivity: from the Sonar Page, press MENU|v to AUTO SENSITIVITY|ENT. 2. Press ^ to SENSITIVITY|ENT and the Sensitivity Control Bar appears. Press v or ^ to pick a different sensitivity setting. When it's set at the desired level, press EXIT. To turn Auto Sensitivity back on: From the Sonar Page, press MENU|v to AUTO SENSITIVITY|ENT|EXIT. NOTE: To return to the original factory setting for Auto Sensitivity, see the entry in this section on Reset Options. If sensitivity is in manual mode, the Reset Options command will switch back to Auto and reset the factory setting at the same time. Tip: For quicker sensitivity adjustments, try leaving the Sensitivity Control Bar on the screen as the chart scrolls. You can see the 78 changes on the screen as you press the up or down arrows. This is handy when there's a lot of clutter in the water, and you are matching the sensitivity to rapidly changing water conditions. changes on the screen as you press the up or down arrows. This is handy when there's a lot of clutter in the water, and you are matching the sensitivity to rapidly changing water conditions. The default color scheme for the sonar chart is grayscale, but we offer other variations to suit your viewing preferences. Y...

Este manual também é adequado para os modelos :
Sounders - FishElite 480 (5.07 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias