Log:
Assessments - 5, GPA: 4.6 ( )

Instruções de Operação Casio, Modelo fx-7400G PLUS

Fabricante : Casio
Arquivo Tamanho: 1.72 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


•Ensure that Prog “file name” is not used to return from subroutines to main routine. If used, delete any unnecessary Prog “file name”. • Trace the subroutine jump destinations and ensure that no jumps are made back to the original program area. Ensure that returns are made correctly. Appendix Appendix Message Stk ERROR Mem ERROR Arg ERROR Dim ERROR Com ERROR Transmit ERROR! Receive ERROR! Memory Full! Meaning •Execution of calculations that exceed the capacity of the stack for numeric values or stack for commands. 1 Not enough memory to hold function input in the Graph Mode for graph drawing. 2 Not enough memory to hold function input in the TABLE Mode. 3 Not enough memory to store data in list function. •Incorrect argument specification for a command that requires an argument. • Illegal dimension used during list calculations. •Problem with cable connection or parameter setting during program data communications. •Problem with cable connection or parameter setting during data communications. •Problem with cable connection or parameter setting during data communications. •Memory of receiving unit became full during program data communications. Countermeasure •Simplify the formulas to keep stacks within 10 levels for the numeric values and 26 levels for the commands. •Divide the formula into two or more parts. 123 •Keep the number of variables you use for the operation within the number of variables currently available. •Simplify the data you are trying to store to keep it within the available memory capacity. •Delete no longer needed data to make room for the new data. Correct the argument. •Fix n, Sci n : n = integer from 0 through 9. • Lbl n , Goto n : n = integer from 0 through 9. •Check list dimension. •Check cable connection. •Check cable connection. •Check cable connection. •Delete some data stored in the receiving unit and try again. Appendix Appendix Appendix D Input Ranges Function Input ranges Internal digits Precision Notes sinx cosx tanx (DEG) |x| < 9 . 109° (RAD) |x| < 5 . 107.rad (GRA) |x| < 1 . 1010grad 15 digits As a rule, precision is ±1 at the 10th digit.* However, for tanx: |x| G GGGGG 90(2n+1):DEG |x| G GGGGG ./2(2n+1):RAD |x| G GGGGG 100(2n+1):GRA sin–1x cos–1x |x| < 1 " " tan–1x |x| < 1 . 10100 logx Inx 1 . 10–99 < x < 1 . 10100 " " 10x –1 . 10100 < x < 100 ex –1 . 10100 " " < x < 230.2585092 x 0 < x < 1 . 10100 " " x2 |x| <1 . 1050 1/x |x| < 1 . 10100 , x G GGGGG 0 " " 3 x |x| < 1 . 10100 x! 0 < x < 69 " " (x is an integer) Result < 1 . 10100 nPr n, r (n and r are integers) " " nCr 0 < r < n, n < 1 . 1010 Pol (x, y) < 1 . 10100x2 + y2 " " Rec (r ,.) |r| < 1 . 10100 (DEG) |.| < 9 . 109° (RAD) |.| < 5 . 107. rad " " However, for tan.: |.| G GGGGG 90(2n+1):DEG |.| G GGGGG ./2(2n+1):RAD (GRA) |.| < 1 . 1010grad |.| G GGGGG 100(2n+1):GRA 202 Appendix Appendix Function Input ranges Internal digits Precision Notes ° ’ ” <. ° ’ ” |a|, b, c < 1 . 10100 0 < b, c |x| < 1 . 10100 Sexagesimal display: |x| < 1 . 107 15 digits As a rule, precision is ±1 at the 10th digit.* ^(xy) x > 0: –1 . 10100 < y logx < 100 x = 0 : y > 0 x < 0 : y = n, (n is an integer)1–––– –– 2n+1 " " However; –1 . 10100 < y log |x| < 100 x y y > 0 : x G GGGGG 0 –1 . 10100 < logy < 100 y = 0 : x > 0 y < 0 : x = 2n +1, (n G GGGGG 0, n is an integer) However; –1 . 10100 < log |y| < 100 1–– x 1 –– n 1–– x " " ab/c Total of integer, numerator and denominator must be within 10 digits (includes division marks). " " STAT |x| < 1 . 1050 |y| < 1 . 1050 |n| < 1 . 10100 x.n, y.n, x, y, a, b, c, r : n G GGGGG 0 x.n–1, y.n–1: n G GGGGG 0, 1 " " * For a single calculation, calculation error is ±1 at the 10th digit. (In the case of exponential display, calculation error is ±1 at the last significant digit.) Errors are cumulative in the case of consecutive calculations, which can also cause them to become large. (This is also true of internal consecutive calculations that are performed in the case of ^(xy), x y, x!, 3 , nPr, nCr, etc.) In the vicinity of a function’s singular point and point of inflection, errors are cumulative and may become large. Appendix Appendix Appendix E Specifications Variables: 26 Calculation range: ±1 . 10–99 to ±9.999999999 . 1099 and 0. Internal operations use 15-digit mantissa. Exponential display range: Norm 1: 10–2 > |x|, |x| > 1010 Norm 2: 10–9 > |x|, |x| > 1010 Program capacity: 20,000 bytes (max.) Power supply: Main: Two AAA-size batteries (LR03 (AM4) or R03 (UM-4)) Back-up: One CR2032 lithium battery Power consumption: 0.05W Battery life Main: LR03 (AM4): Approximately 1,500 hours (continuous display of main menu) Approximately 700 hours (continuous operation) R03 (UM-4): Approximately 900 hours (continuous display of main menu) Approximately 400 hours (continuous operation) Back-up: Approximately 2 years (when main batteries are not supplying power) Auto power off: Power is automatically turned off approximately six minutes after last operation. The calculator automatically turns off if it is left for abo...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias