Log:
Assessments - 4, GPA: 4.8 ( )

Instruções de Operação Monessen Hearth, Modelo SLDVT-30NM

Fabricante : Monessen Hearth
Arquivo Tamanho: 4.04 mb
Arquivo Nome : Lennox_Superior_SLDVT_Installation_506009-01.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


The carbon monoxide detector must comply with NFPA 720, be ANSI/UL 2034 listed and be ISA certified. • A metal or plastic identification plate must be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade and be directly in line with the horizontal termination. The sign must read, in print size no less than one-half (1/2) inch in size, GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS. NEW YORK CITY, NEW YORK (MEA) Installation of these fireplaces are approved for installation in New York City in the US state of New York. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 5 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • INSTALLATION INSTRUCTIONS Figure 3 - Typical Locations NOITACILPPA TNEV POT APPLICATION TOP VENT TOP VENT APPLICATION RECESSED INSTALLATION TOP VENT APPLICATION APPLICATION TOP VENT APPLICATION TOP VENT HORIZONTAL VENT (Top Vent Application) VERTICAL VENT (Top Vent Application) Note: When the unit is installed with one side flush with a wall, the wall on the other side of the unit must not extend beyond the front edge of the unit. LOCATION In selecting the location, the aesthetic and functional use of the appliance are primary concerns. However, vent system routing to the exterior and access to the fuel supply are also important. Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies (Figure 3). En raison des temperatures elevees, l’appareil devrait etre installe dans un endroit ou il y a peu de circulation et loin du mobilier et des tentures (Figure 3). The location should also be free of electrical, plumbing or other heating/air conditioning ducting. These direct-vent appliances are uniquely suited for installations requiring a utility shelf positioned directly above the fireplace. Utility shelves like these are commonly used for locating television sets and decorative plants. Be aware that this is a heat producing appliance. Objects placed above the unit are exposed to elevated temperatures. Do not insulate the space between the appliance and the area above it (see Figure 8). The minimum height from the base of the appliance to the underside of combustible materials used to construct a utility shelf in this fashion is shown in Figure 8. The appliance should be mounted on a fully supported base extending the full width and depth of the unit. The appliance may be located on or near conventional construction materials. However, if installed on combustible materials, such as carpeting, vinyl tile, etc., a metal or wood barrier covering the entire bottom surface must be used. Cold Climate Insulation For cold climate installations, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level. Gas line holes and other openings should be caulked or stuffed with unfaced fiberglass insulation. If the fireplace is being installed on a cement slab in cold climates, a sheet of plywood or other raised platform can be placed underneath to prevent conduction of cold transferring to the fireplace and into the room. It also helps to sheetrock inside surfaces and tape for maximum air tightness and caulk firestops. MANUFACTURED HOME REQUIREMENTS This appliance may be installed in an aftermarket permanently located, manufactured home and must be installed in accordance with the manufacturer's instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or the Standard for Installation in Mobile Homes, CAN/CSA Z240 MH Series, in Canada. Cet appareil peut etre installe comme du materiel d'origine dans une maison prefabriquee (E.U. seulement) ou mobile et doit etre installe selon les instructions du fabricant et conformement a la norme Manufactured Home Constructions and Safety, Title 24 CFR, Part 3200 aux Unis ou a la norme Can/CSA-Z240 Serie MM, Maisons mobiles au Canada. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. Cet appareil doit etre utilise uniquement avec le type de gaz indique sur la plaque signaletique. Cet appareil ne peut etre converti a d'autres gaz, sauf si une trousse de conversion est utilisee. CAUTION: Ensure that the cross members are not cut or weakened during installation. The structural integrity of the manufactured home floor, wall, and ceiling / roof must be maintained. CAUTION: This appliance must be grounded to the chassis of the manufactured home in accordance with local codes or in the absence of local codes, with the National Electrical Code ANSI / NFPA 70 - latest edition or the Canadian Electrical Code CSA C22.1 - latest edition. 6...

Este manual também é adequado para os modelos :
Lareiras - SLDVT-30NM (4.04 mb)
Lareiras - SLDVT-30NM (4.04 mb)
Lareiras - SLDVT-30NM (4.04 mb)
Lareiras - SLDVT-30NM (4.04 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias