Log:
Assessments - 2, GPA: 4.5 ( )

Instruções de Operação Lopi, Modelo Freedom Fireplace Insert

Fabricante : Lopi
Arquivo Tamanho: 1.48 mb
Arquivo Nome : b2bcc0e7-d649-4dc8-85ba-957faf33b96c.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Follow the liner manufacturer's insturctions for installation and support. Airtight Insulated Clean-Out Remove damper or wire it open Figure 6 NOTE: Most factory-built chimney manufacturers make stainless steel chimney liners, either flexible or rigid. This provides a wide variety of installation options. Make sure to follow the manufacturer's instructions for installation and support. © Travis Industries 100-01162 4041105 Installation (for qualified installers only) 13 Installation (for qualified installers only) 13 Insert with Direct Connection (Masonry Fireplace) AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA Combustible Mantle See the section "Insert Placement Requirements" for minimum clearances and hearth required. Surround Panels Flue Liner Stainless steel chimney connector must Extend 1' past the block-off plate or to the flue liner Airtight Insulated Clean-Out Remove damper or wire it open Block-off plate or damper adapter Figure 7 NOTE: Direct connections require installation of an airtight block-off plate or damper adapter (see "Block-off Plate Installation" on page 11). © Travis Industries 100-01162 4041105 14 Operating Your Appliance 14 Operating Your Appliance Safety Notice: If this appliance is not properly installed, a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. Read and follow all of the warnings on pages 4 and 5 of this manual. Before Your First Fire Verify the Installation Before starting the stove, verify that it is properly installed and all of the requirements in this manual have been followed. Keep all flammable materials 36" away from the front of the stove (drapes, furniture, clothing, etc.). Curing the Paint 2 to 4 hours This heater uses a heat-activated paint that will emit some fumes while starting the first fire. Open doors and windows to the room to vent these fumes. This typically lasts two to four hours. You may also notice oil burning off of the interior of the heater. This rust-stopping agent will soon dissipate. Door Gasket - The door gasket might adhere to the paint on the front of the heater. Leave the door slightly ajar for the first fire and be careful when opening the door after the first fire. AAAAAAAAA Over-Firing the Stove This stove was designed to operate at a high temperature. But due to differences in vent configuration, fuel, and draft, this appliance can be operated at an excessive temperature. If the stove top or other area starts to glow red, you are over-firing the stove. Shut the air control down to low and allow the stove to cool before proceeding. Over-firing may lead to damage of plated surfaces. If you are uncertain of over-firing conditions, we suggest placing a stove thermometer (e.g. Rutland® Model 710) directly over the door on the stove top temperatures exceeding 800° are generally considered over-firing and will void the warranty. Opening the Door Rotate the door handle. Swing the door open. The door becomes hot during use. Use a glove to open the door if the handle is hot. To prevent smoke from entering the room, open the bypass before opening the door (see following page for directions). You can also open the door a small amount and let air enter the firebox. © Travis Industries 100-01162 4041105 A. Operating Your Appliance 15 Bypass Operation The bypass controls the flow of smoke inside the heater. When pulled out, smoke goes directly up the flue, creating more draft. When pushed in, the smoke goes around the baffle, utilizing the secondary combustion and making the heater more efficient. • When starting or re-loading, pull the bypass out. • During normal operation, push the bypass in. Bypass Pulled Out Used for starting and re-loading A. Use the included pull tool AA to operate the bypass rod A. Bypass Pushed In Used for normal operation AAAAAAAAAAAAAAAAAAAAAAAAAAAAAA © Travis Industries 100-01162 4041105 16 Operating Your Appliance 16 Operating Your Appliance Starting a Fire Since the dawn of time man has debated the best way to start a fire. Some use the boy-scout "tee-pee", some prefer the "tic-tac-toe" stack. Either way, review the hints and warnings below to ensure proper fire starting. • Make sure the air control is pushed in and the by-pass pulled out. If additional air is needed, open the doors 1/4" during the first five minutes of start-up. Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or "freshen up" a fire in this stove. Keep all such liquids well away from the stove while it is in use. If using a firestarter, use only products specifically designed for stoves - follow the manufacturer's instructions carefully. If the smoke does not pass up the chimney, ball up one sheet of newspaper, place it in the center of the firebox and light it. This should start the chimney drafting (this eliminates "cold air blockage"). Use plenty of kindling to...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias