Log:
Assessments - 4, GPA: 3.5 ( )

Instruções de Operação Superior, Modelo 500

Fabricante : Superior
Arquivo Tamanho: 976.79 kb
Arquivo Nome : Lennox_Hearth_D_Installation_700005.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


116-F-13-4) to ANSI Z21.88-2002 (in Canada, CSA-2.33-2002), and CAN/CGA-2.17-M91 in both USA and Canada, as vented gas fireplace heaters. Both millivolt and electronic versions of these appliances are listed by Omni-Test Laboratories for installation in bedrooms and mobile homes. Installation must conform to local codes. In the absence of local codes, installation must comply with the current National Fuel Gas Code, ANSI Z223.1. (In Canada, the current CAN-1 B149 installation code.) Electrical wiring must comply with the National Electrical Code ANSI/ NFPA 70 - (latest edition). (In Canada, the current CSA C22-1 Canadian Electrical Code.) NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION MAY VOID THE WARRANTY, CERTIFICATION AND LISTINGS OF THIS UNIT. GENERAL INFORMATION Note: Installation and repair should be performed by a qualified service person. The appliance should be inspected annually by a qualified professional service technician. More frequent inspections and cleanings may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that the control compartment, burners and circulating air passage ways of the appliance be kept clean. S'assurer que le bruleur et le compartiment des commandes sont propres. Voir les instructions d'installation et d'utilisation qui accompagnent l'appareil. Provide adequate clearances around air openings and adequate accessibility clearance for service and proper operation. Never obstruct the front openings of the appliance. These appliances are designed to operate on natural or propane gas only. TYPICAL INSTALLATION Figure 1 Millivolt Models Millivolt Models Input of millivolt models is shown in the following table: Millivolt Models with Manually-Modulated Gas Valve Natural Gas Propane Gas D, DT, DR Series Input rate (BTU/H) D, DT, DR Series Input rate (BTU/H) 500 17,500 to 23,000 500 17,500 to 23,000 600 21,500 to 29,000 600 22,500 to 29,000 800 24,000 to 32,000 800 25,500 to 32,000 Electronic Models Electronic models have a fixed rate gas valve. Input of electronic models is shown in the following table: Electronic Models with Fixed-Rate Gas Valve Natural and Propane Gas D, DT, DR Series Input rate (BTU/H) 500 23,000 600 29,000 800 32,000 All Models Maximum manifold pressure is 3.5 in. w.c. (0.87 kPa) for natural gas and 10 in. w.c. (2.49 kPa) for LP/Propane gas. Installations at Altitudes of 0 to 4500 ft.Units are tested and approved for elevations of 0 to 4500 feet (0 to 1372 meters). Installations at Altitudes above 4500 ft.For elevations above 4500 feet (1372 meters), install the unit according to the regulations of the local authorities having jurisdiction and, in the USA, the latest edition of the National Fuel Gas Code (ANSI Z223.1) or, in Canada, the latest edition of the CAN1-B149.1 and .2 codes. Table 1shows the units' gas orifice size for the elevations indicated. D, DT, DR Orifice size Elevation Feet (meters)Series Nat. Prop. 500 0.090 in. #54 0-4500 (0-1370) 600 #36 #52 800 #33 0.065 in. The millivolt appliances are manually controlled and feature a spark ignitor (piezo) that allows the appliance's pilot gas to be lit without the use of matches or batteries. This system provides continued service in the event of a power outage. Do not use these appliances if any part has been under water. Immediately call a qualified, professional service technician to inspect the appliance and to replace any parts of the control system and any gas control which have been under water. Ne pas se servir de cet appareil s'il a ete plonge dans l'eau, completement ou en partie. Appeler un technicien qualifie pour inspecter l'appareil et remplacer toute partie du systeme de controle et toute commande qui ont ete plonges dans l'eau. This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. Cet appareil peutetre installe dans un maison prefabriquee (E.-U. seulement) ou mobile deja installee a demeure si les reglements locaux le permettent. Cet appareil doit etre utilise uniquement avec les types de gaz indiques sur la plaque signaletique. Ne pas l'utiliser avec d'autres gaz sauf si un kit de conversion certifie est installe. Test gage connections are provided on the front of the millivolt gas control valve (identified IN for the inlet and OUT for the manifold side). A ..." NPT test gage connection is provided at the inlet and outlet side of the electronic gas control valve. Minimum inlet gas pressure to these appliances is 5.0 inches water column (1.24 kPa) for natural gas and 11 inches water column (2.74 kPa) for propane for the purpose of input adjustment. Maximum inlet ga...

Este manual também é adequado para os modelos :
Lareiras - 600 (976.79 kb)
Lareiras - 800 (976.79 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias