Fabricante : Desa
Arquivo Tamanho: 4.74 mb
Arquivo Nome : af29e626-f676-d1e4-255f-4810c780d79e.pdf
|
Facilidade de uso
In the event of a power outage, you can use this fireplace as a heat source. FRAMING AND FINISHING Figure 4 shows typical framing of this fireplace. Figure 5 shows framing for corner installation. All minimum clearances must be met. For available accessories for this fireplace, see Accessories on page 31. If you are using a separate combustible mantel piece, refer to Figure 6 for proper installation height. You can install noncombustible mantels at any height above the fireplace. Note:Noncombustible mantels may discolor! A B E F G H D C Nailing Tabs 36" Models 42" Models A 35 3/4" 41 5/8" B 15" 21 5/8" C 49 5/8" 58 1/2" D 10 3/8" 13 1/2" E 13 3/4" 16 3/4" F 41" 48" G 41 3/4" 48 3/4" H 68 1/2" 81 1/2" Figure 5 - Framing Clearances for Corner Installation C B A D E F G Top of Louver Opening 3 2 1 4 5 6 7 Wall Ref. Mantel Depth Ref. Mantel from Top of Louver Opening 1 14" (356mm) A 16" (406mm) 2 12" (305mm) B 14" (356mm) 3 10" (254mm) C 12" (305mm) 4 8" (203mm) D 10" (254mm) 5 6" (152mm) E 8" (203mm) 6 4" (101mm) F 6" (152mm) 7 2" (51mm) G 4" (101mm) B A C Vertical Termination D Horizontal Termination 36" Models 42" Models A 36 1/2" 40 1/2" B 41 3/4" 48 3/4" C 27 3/8" 29 1/2" D 24 7/8" 27" Figure 4 - Framing Clearances for Installation Against an Exterior Figure 6 - Clearances for Combustible Mantels Wall For more information, visit more information, visit 6 6 LOCATION OF TERMINATION CAP LOCATION OF TERMINATION CAP Fixed Closed Openable Fixed Closed OpenableV V V V V V X X V X G G J F B B K N H I A N E LD B M C B V VA G G B TERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA (TERMINATION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony I = clearance to service regulator vent outlet [*72 inches (1829mm) [*12 inches (305mm) minimum] minimum] B = clearance to window or door that may be opened J = clearance to non-mechanical air supply inlet to building or the [12 inches (305mm) minimum] combustion air inlet to any other fireplace [*12 inches (305mm) C = clearance to permanently closed window [minimum 12 inches minimum] (305mm) recommended to prevent condensation on window] K = clearance to a mechanical air supply inlet [*72 inches (1829mm) D = vertical clearance to ventilated soffit located above the terminal minimum] within a horizontal distance of 24 inches (610mm) from the L = clearance above paved side-walk or a paved driveway located on center-line of the terminal [18 inches (457mm) minimum] public property [*84 inches (2133mm) minimum] E = clearance to unventilated soffit [12 inches (305mm) minimum] M = clearance under veranda, porch, deck [*12 inches (305mm) minimum ] F = clearance to outside corner (see below) N = clearance above a roof shall extend a minimum of 24 inches (610mm) G = clearance to inside corner (see below) above the highest point when it passes through the roof surface and H = *not to be installed above a meter/regulator assembly within any other obstruction within a horizontal distance of 18 inches (457mm) 36 inches (914mm) horizontally from the center-line of the regulator vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings* only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/SGA B149 (.1 or .2) Installation Codes (1991) for Canada or for U.S.A. installation follow the current National Fuel Gas Code, ANS Z223.1 Note: Local codes or regulations may require different clearances Termination Clearances for Buildings with Combustible and Noncombustible Exteriors Inside Corner Outside Corner Recessed Location V A A = 6" (152mm) V B B = 6" (152mm) Balcony with No Side Wall Balcony with Perpendicular Side Wall V G H G = 12" (305mm) minimum clearance V J Combustible & Noncombustible H = 24" (610mm) J = 20" (508mm) C = Maximum depth of 48" (1219mm) for recessed location D = Minimum width for back wall of recessed location Combustible - 38" (965mm) Noncombustible - 24" (610mm) E = Clearance from corner in recessed location- Combustible - 6" (152mm) Noncombustible - 2" (51mm) C D C Figure 7 - Minimum Clearances for Termination Cap For more information, visit more information, visit VENTING INSTALLATION INSTRUCTIONS Installation Precautions 7 VENTING INSTALLATION INSTRUCTIONS NOTICE: Read these instructions completely before attempting installation. These models are tested and approved for use with DESA International (direct-vent) pipe components and terminations. The venting system must terminate on the outside of the structure and can not be attached to a chimney or flue system serving a separate solid fuel or gas burning appliance. A direct-vent appliance must have its own venting system. DO NOT common vent this appliance. These models are approved to be vented either horizontally through an outside wall or vertically throu...