Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação Raypak, Modelo RFSDV34RFNAU

Fabricante : Raypak
Arquivo Tamanho: 367.85 kb
Arquivo Nome : 1e722fc6-9df3-4f76-8e08-eb40b4643473.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Refer to Australian Standard AS5601 Gas Installations. The gas fitting line can be brought in through the rear or the bottom of the appliance. Openings are provided on the bottom behind the valve to allow for the gas fitting line installation and testing of any gas connection. It preferable to bring the fitting line in from the rear right side of the valve as this allows fan installation or removal without the need to disconnect the gas fitting line. Note: When making the gas connection to the appliance inlet fitting, hold the 10mm 3/8” BSP fitting with a spanner when tightening the gas inlet pipe compression nut. For Propane installations an approved gas regulator must be fitted in accordance with AS5601. Ensure copper tube meets the requirements of Australian Standard AS1432 Type B. Note: Heater must be tested for correct operation by the installer after installation is complete. Part 3: General Flue Installation Underside of gas cowl must be at least 500mm above highest point of the roof. Text Box: This appliance is approved for an installation with a maximum flue height of 12m and a minimum flue height of 3m. Suspend a plumbline from the ceiling to the centre of the flue spigot. Mark the centre of the flue spigot on the ceiling. Prior to cutting the ceiling ensure that there is at lease 25mm clearance from any combustible materials. Fit ceiling ring, flue and flue cover. Part 4: Operating Instructions NOTE: Carbon deposits maybe present on the glass and logs. This is normal and must be cleaned when the heater is serviced or the glass door is cleaned. Please refer to the General Glass Information section on page 15. General Glass Information Warning: Only glass approved for use by Raypak Australia may be used for replacement. The use of substitute glass will void all warranties. Take care to avoid breaking the glass. Warning: Under no circumstances is this appliance to be operated without the front glass or with a broken glass. Replacement of the glass including the gasket as supplied by Raypak Australia should be done by a licensed and qualified service person. Window Frame Assembly Removal 1. Shut off gas. (see lighting instructions) 2. If the unit has been operating, let it cool. 3. Open the two side doors. 4. Open the clamps on the two sides (Fig. 2) 5. Pull the frame forward. 6. To re-install window frame assembly, follow the above procedure in reverse Fig. 2 Window frame removal Glass Cleaning It is necessary to periodically clean condensation and film from the glass. Condensation, which is normal during start up, forms on the inside of the glass and causes lint, dust and other air-borne particles to cling. Initial paint curing may also deposit a slight film on the glass. Clean the glass two or three times with a non-ammonia based household cleaner and warm water. (We recommend gas fireplace glass cleaner.) After the initial cleaning, clean the glass two or three times during each operating season, depending on the environment. Log Set and Lava Rock Material Installation 1. Remove window frame assembly. (See window frame removal assembly section) 2. Remove logs from packaging. Warning: Plastic bags are not toys and should be kept away from children and infants. 3. Place rear log (KR10) on rear bracket (ensure log is seated. properly, levelled and centred to the unit), so it will not move from side to side and is firmly positioned on the bracket. 4. Slip front ember log (KR7) down behind the front deflector. 5. Place front left log (KR8) on top of burner, left side. Using the bottom holes in the log, locate it into the left bracket log locator studs. 6. Place front right log (KR9) on top of burner, right side. Use the log’s bottoms holes to locate it into the right bracket log locator studs. 7. Place burner lava rock on top of burner between the ember log and the two front logs. 8. Place top left log (KR11) onto locator notches. Ensure the log is secure. 9. Place top right log (KR12) onto locator notches. Ensure log is secure. Fig. 3 Logs for the RFSDV34 gas log fire Maintenance Raypak Australia recommends that this appliance is serviced by qualified and licensed Service Person at least once a year. For service repairs and maintenance, Contact Rheem Service on 131 031. Flame and Temperature Adjustment The appliance is fitted with the Honeywell Radio Frequency control valve and all adjustments are performed with the use of a remote controller. See instructions packaged with the Remote Controller or refer to page 16 in this manual for operating instructions. Flame Appearance Periodically perform a visual check of the pilot and burner flames by comparing them to the illustrations below (refer to figures 4 and 5). If any flames appear to be abnormal, place a service call. Fig 4. DVT pilot flame Fig.5 RFSDV34 flames Lighting Instructions FOR YOUR SAFETY, READ BEFORE LIGHTING A. This heater has a pilot which must be lit manually. To light the pilot, follow these instructions exactly. B. BEFORE LIGHTING, s...

Este manual também é adequado para os modelos :
Lareiras - RFSDV34RFNAU (367.85 kb)
Lareiras - RFSDV34RFPAU (367.85 kb)
Lareiras - RFSDV34RFPAU (367.85 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias