Log:
Assessments - 5, GPA: 3.6 ( )

Instruções de Operação Royal Consumer Information Products, Modelo G31

Fabricante : Royal Consumer Information Products
Arquivo Tamanho: 265.56 kb
Arquivo Nome : 845eb79f-783c-4def-8b4b-fa84957f9709.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


MAXIMUM HEAT INPUT 6 kW - 20470 Btu/h (Gross) Royal Cozyfires are manufactured by: CROSSLEE plc Aber Park Industrial Estate, Aber Road, Flint, Flintshire. CH6 5EX Spares Tel 01422 203963 Fax: 01422 204475 Service (GSA Ltd) 01703 516611 Customer Service 01422 200660 Fax 01422 206304 *Technical Help Line 0906 8633268 *Calls charged at 50p per minute 0102 095 50251 . INSTALLATION and SERVICING INSTRUCTIONS THIS CAT I3P APPLIANCE IS FOR USE ON PROPANE GAS G31 AT A SUPPLY PRESSURE OF 37 mbar IN GB & IE HAND THESE INSTRUCTIONS TO THE USER DESCRIPTION This Royal Cozy Fires Decorative Fuel Effect gas fire has been developed to give a realistic coal burning appearance with the instant control and convenience of gas. The fire has been constructed to enable it to be installed into applications where the warmth and comfort of an open fire and high radiant heat is required. This appliance is intended for decorative purposes, the coal bed uses ceramic simulated coals to give a realistic appearance and to allow secondary air to be entrained into the bed to ensure clean combustion. An aerated single port steel burner is used running parallel across the front of the fire. A single gas control with a variable high to low setting is used with a Flame Supervision Device (FSD). This is fitted to ensure that should the pilot flame be extinguished for any reason, (including turning off the appliance), the gas supply to the burner is cut off until a full lighting sequence is repeated. A separate Piezo igniter is used to ignite an Oxy/pilot sensor (O.D.S) that will cause the appliance to ‘shut off’ in the event of continued spillage occurring under hazardous or blocked flue conditions. The fire bed consists of ceramic fibre components and coals all of that are removable for cleaning purposes when required. It is important when relaying the coal bed and coals to follow the instructions correctly. This appliance is suitable for installations into the following flues: 7" minimum diameter flues (CLASS 1), 5" minimum diameter flues (CLASS 2), Pre-cast flues to BS 1289 Pt 1 1986 The installations must always be used in conjunction with a suitable hearth and surround. . TECHNICAL DATA Overall height of fire Overall width of fire Minimum height of opening required Minimum width of opening required Forward projection from opening (without front & fret) Depth behind opening = = = = = = 602 mm 505 mm 550 mm 396 mm 50 mm 122 mm TYPE OF GAS G31 Only Supply Pressure 37 mbar +/- 1mbar (Cold) GAS INPUTS (Gross) Max 6 kW (20470 Btu/h) Min 3.5kW (11940 Btu/h) Pilot 0.26 kW ( 890 Btu/h) Main Injector Type Stereomatic 046-19-196-047M Pilot OP. Oxy/Pilot 1PG 9214 GAS CONNECTION 8mm O/D Tube WEIGHT 11.5 kg without front & fret 14.5 kg with front & fret. Page 2 Installation Regulation and Requirements The appliance must be installed by a competent person in accordance with the current Gas Safety (Installation and Use) Regulations 1994 (as amended) or the rules in force and in accordance with the manufacturers instructions, failure to do so could lead to prosecution. The following are the relevant Codes of Practice and British Standards. The Building Regulations issued by the Department of the Environment The Building Standards (Scotland)(Consolidation) Regulations issued by the Scottish Development Department. BS 8303 1986 BS 5440 Pt1 1990 & Pt2 1989 BS 1251 1987 BS 5871 Pt2 1991 & Pt3 1991 BS 6891 1988 BS 6461 Pt1 1984 BS 715 1993 BS 1289 Pt1 1986 BS 7566 Pts 1-4 1992 Important Notes Areas of this appliance will become hot after prolonged running and it is recommended that for the protection of the very young, elderly and infirm a fireguard conforming to BS 6539 or BS 6778 be used. The type of front and fret recommended is shown in this instruction, it has a perforated fret to allow air to be drawn into the coal bed for combustion and over the controls for cooling purposes. If other fronts and frets are to be used they must have a minimum open area in the fret of 20 sq. cms and 60 sq. cms in the front. Care should be taken to prevent any damage being caused to surrounding soft furnishings or decor e.g. many embossed vinyl wall coverings may become discoloured if located too close to the appliance. Clearances required for combustible shelves are shown in fig 1. Care should be taken to ensure that when the appliance is installed into a Pre-cast flue, the chimneybreast is lined to prevent the plaster etc, cracking through excessive temperatures. A hearth must always be provided to project forward of the opening a minimum of 340mm depth and 150mm either side of the fire opening. The hearth must be a minimum thickness of 12mm with a perimeter height of 50mm, to deter combustible materials, carpets etc, being placed on the hearth. The area under the firebox must have a minimum non-combustible thickness of 25mm. In most installations a back panel will be required, this will also need a minimum fire resistance rating of Class 0 (100OC). Ventilation is require...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias