|
Facilidade de uso
Note 1: Local codes or regulations may require different clearances. Note 2: Fireplaces in an alcove space (spaces open only on one side and with an overhang) are permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1) There must be a 3 ft minimum between terminations or between the fireplace and termination. 2) All mechanical air intakes within 10 ft of the top of the fireplace opening must be a minimum of 3 ft below the top of the fireplace opening. 3) All gravity air intakes within 3 ft of the fireplace must be a minimum of 1 ft below the face top opening. This fireplace is approved for installation in screened porches with the following guidelines: Minimum porch area - 96 sq ft Minimum ceiling height - 92 in. Minimum of two walls must be screened or open Minimum top of screen height, side walls - 6 ft 8 in. Minimum screen area - 64 sq ftNote: There may be some odor and small amounts of soot associated with burning the fireplace in a screened porch. Ensuring good cross draft ventilation and routine maintenance of the fireplace will maximize comfort and cleanliness. . . . . . . . . Q = 72 in. C = 72 in.. . . . . . . . . clearance below an opperable window. . . . . . CPGQA Step 2. Level the firebox by checking the top edge of the firebox. Shim if necessary. Step 3. The fireplace should be secured to the side framing members, using the full length nailing flange located on both sides of the fireplace. Use 8d nails, or screws. Important: Under no circumstances shall the firebox top spacers be removed or modified. The header may be in direct contact with the top spacers but must not be supported by them or notched to fit around them. Step 4. Identify the desired location for the battery pack/ON/OFF switch junction box. This should be easily accessible and connivent for use. Avoid installing where the opening could be blocked by snow, bushes, etc. Also, considerations need to be made to avoid water infiltration. The electrical junction box must be positioned within range of the electrical umbilical cord (9 feet). Route the umbilical cord to the box to ensure proper length. Secure the umbilical cord per appropriate local and national electrical codes. Fireplace Installation Step 1. Frame these appliances as illustrated in Figures 7 through 9. All framing details must allow for a minimum clearance to combustible framing members, as shown in Figure 4 on page 5. Also refer to Fireplace Specifications on Page 8. Headers may be in direct contact with the appliance top spacers but must not be supported by them or notched to fit around them. All construction above the appliance must be self supporting. Do Not use the appliance for structural support. Note: The framed depth from a framed wall, must always be measured from a finished surface. If a wall covering such as durrock is to be attached to the rear wall, then the depth must be measured from the wall surface. It is important that this dimension be exact. Note: Non-combustible framing members are not required, but are recommended. Routing Gas Line Route a 1/2" (13 mm) gas line along the inside of the right side framing as shown in Figure 5. Gas lines must be routed, constructed and made of materials that are in strict accordance with local codes and regulations. All appliances are factory-equipped with a flexible gas line connector and 1/2 inch shutoff valve. (See Figure 12 on page 11). right SideFront CornerOf FireplaceFraming3-3/4" (95 mm) -3/4" (44 mm) Figure 5 Note: An addiional inlet has been provided on the left side (see Figure 6 ). fireplace specifications Gas LineAccess- (Both Sides) Access Opening forumbilical Cord - right Side Onlytop ViewACB (25) 7- / 6( 79) Front Viewright Side Viewtop Stand-OffSpacers (4places) 5-3/4( 46) 5-3/4( 46) Top of Firebox OpeningBottom ofFireboxOpening dimensions - Inches (millimeters) Model No.ABCE36OdG37(940) 4 -3/4( 06 ) 23- /2(597) 43( 092) 47-3/4( 2 3) 29- /2(749)E42OdG -3/428- /2(724) 4 -5/ 6( 049) 34- /4(870) 5( 27) 20(508) - 5/ 6(303) 4-3/8( ) Left Side Gas Inlet8- /4(2 0) 2(5 ) ModelShip. Weight (lbs)Shipping VolumeE36OdG230 lbs38 Cu. Ft. Weight And Volume200 lbs35 Cu. Ft. E42OdG Figure 6 framing specifications OpeningE360DGA42-3/4" (1086)48-3/4" (1238) B46-1/2" (1181)46-1/2" (1181) C23-9/16" (599)29-9/16" (751) D11-1/4" (286)14-1/4" (362) E63-1/2" (1613)69-1/2" (1765) F31-3/4" (807)34-3/4" (883) G20-1/2"( 521)20-1/2"( 521) H44-3/16" (1122)49-1/8" (1248) E420DGTable 1 (This Table Corresponds To Figures 7,8 & 9.) Co...
Este manual também é adequado para os modelos :Lareiras - ELITE E36ODGNE (1.65 mb)
Lareiras - ELITE E36ODGNE-H (1.65 mb)
Lareiras - ELITE E36ODGPE (1.65 mb)
Lareiras - ELITE E36ODGPE-H (1.65 mb)