Log:
Assessments - 5, GPA: 4.6 ( )

Instruções de Operação Magnavox, Modelo LSS-40CP

Fabricante : Magnavox
Arquivo Tamanho: 3.76 mb
Arquivo Nome : 61137303-9849-4b44-911b-9179232a0136.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


FOR YOUR SAFETY: What to do if you smell gas: • DO NOT light any appliance. • DO NOT touch any electrical switches. • DO NOT use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow your gas suppliers instructions. • If your gas supplier cannot be reached, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. POUR VOTRE SECURITE: Ne pas entreposer ni utiliser d'essence ni d'autre vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil. POUR VOTRE SECURITE: Que faire si vous sentez une odeur de gaz: • Ne pas tenter d'allumer d'appareil. • Ne touchez a aucun interrupteur. Ne pas vous servir des telephones se trouvant dans le batiment ou vous vous trouvez. • Evacuez la piece, le batiment ou la zone. • Appelez immediatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur. • Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service dos incendies. L'installation et service doit etre execute par un qualifie installeur, agence de service ou le fournisseur de gaz. AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE LES INSTRUCTIONS DONNEDANS CETTE NOTICE POUR REDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU POUR EVITER TOUT DOMMAGE MATERIEL, TOUTE BLESSURE OU LA MORT.WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. OTL Report No. 116-F-02-05 CONGRATULATIONS! CONGRATULATIONS! Please read and carefully follow all of the instructions found in this manual. Please pay special attention to the safety instructions provided in this manual. The Homeowner's Care and Operation Instructions included here will assure that you have many years of dependable and enjoyable service from your LENNOX product. TABLE OF CONTENTS Introduction ..................................... page 2 General Information ......................... page 2 Operation/Care of Your Appliance.... page 3 RF Comfort Control Valve Operation page 3 Transmitter Operation...................... page 4 Trouble shooting ............................. page 5 Glass Cleaning ................................. page 6 Maintenance .................................... page 6 Maintenance Schedule ..................... page 7 Front Glass Enclosure Panel, Removal and Installation ............... page 8 Burner Adjustments ......................... page 8 Flame Appearance and Sooting ....... page 8 Adjustment ...................................... page 9 Vent Restrictor ................................ page 9 Log Placement ................................. page 10 Rockwool Placement ....................... page 11 Pilot Inspection ............................... page 11 Warranty .......................................... page 11 Replacement Parts .......................... page 11 Product Reference Information ....... page 11 Accessory Components ................... page 12 Replacement Parts List ..................... page 14 INTRODUCTION The Fireplace models covered in this manual are Direct-Vent sealed combustion vented gas fireplace heaters designed for residential application. Direct-Vent appliances operate with the combustion chamber completely isolated from the inside atmosphere. All air for combustion is brought in from the outside and exhaust gases are vented through the same direct vent, vent system. These appliances feature a comfort control valve which allows remote control of temperature, fan and flame appearance. These appliances also use a spark ignitor (piezo) that allows the appliance's pilot gas to be lit without the use of matches. This system provides continued service in the event of a power outage. The external electrical power (120v) is required to operate the provided circulating blower. These appliances comply with National Safety Standards and are tested and listed by Omni- Test Laboratories (Report No. 116-F-02-5) to ANSI Z21.88-2002 (in Canada, CSA-2.33-2002), and CAN/CGA-2.17-M91 in both USA and Canada, as vented gas fireplace heaters. The Installation must conform to local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1. The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1. DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION MAY VOID THE WARRANTY, CERTIFICATION AND LISTINGS OF THIS UNIT. WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER. ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias