Log:
Assessments - 2, GPA: 3.5 ( )

Instruções de Operação CFM Corporation, Modelo 7000 MVRLC

Fabricante : CFM Corporation
Arquivo Tamanho: 166.93 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


* The glass used on your fireplace is a high temperature ceramic 5 mm thick with a special coating for use with gaseous fuels. Do not replace it with any other material. CAUTION : Do not operate your fireplace without a glass or with a broken glass. BURNER REMOVAL AND INSTALLATION : REMOVAL : 1. Slide the burner to the left and pull toward you. 2. To gain access to the fan, also remove the firebox bottom plate. INSTALLATION : 1. Put the bottom plate back in place. 2. Put the burner assembly back in the firebox and push to the right until it touches the firebox side. Make sure the main orifice is inserted in the venturi tube by looking through the square hole as shown. A silicone washer insures air tightness between the two parts. WARNING : NEVER OPERATE THE GAS INSERT WITHOUT HAVING THE ORIFICE PROPERLY INSERTED EN THE VENTURI TUBE. THIS WOULD RESULT IN SERIOUS DAMAGE TO THE GAS INSERT AND IS A SERIOUS RISK OF FIRE. LOG INSTALLATION : 1. Remove the glass front as described on page 11. 2. Install the longer log in back of the firebox with locating grooves on top. 3. Install the 14” log in the front of the firebox and to the right. Make sure the log is pushed against the metal retainer on the burner face. 4. Place the front of the log with a hole in the second notch from the left in the log holder at the front of the burner and position it back in the back log groove. It should be touching the 14” LOG. 5. Place the smallest log sideways on the top of both the back and 14” logs with the bend toward the front. 6. Put the glass front back in the place. FACE PLATE ASSEMBLY AND INSTALLATION : ASSEMBLY : 1. Bolt the face plate top piece to the left piece using two #10-24 x 1/2 bolts and nuts (B). 2. Place both louver assemblies in position with their pivot rod inserted through the face plate side pieces holes (C). The top and bottom louvers are clearly identified. WARNING : Do not invert the top and bottom louver assemblies, this would damage them because top louvers can withstand to higher temperature. They are marked with stickers at one end. 3. Bolt the face plate left piece to the top using the other two #10-24 x 1/2 bolts and nuts (B). 4. Assemble the decorative gold trim using the two corner brackets (A). 5. Slide the assembled decorative gold trim in place from above the face plate. 6. Insert the switches in the slots located on the right side of the gold trim (E) and (F). INSTALLATIONS : 1. Screw the air deflector on the unit as shown using three #10 x 1/2 metal screws. 2. Bring the face plate in position on the gas insert taking care to slip the air deflector between the top louver and the bottom of the top piece. Secure using four #10 x 1/2 metal screws (D). 3. Connect the slip on the terminals on the rocker switch making sure the wires are in pairs by color. The green wires lead to the valve and the yellow to the fan. WARNING : Do not connect two wires of different color on the same switch, this would result in damage to the valve and possible harm to the operator. REFRACTORY PANELS INSTALLATIONS : 1. Remove the front glass as described on page 11. 2. Remove the logs from the firebox. 3. Install the two sides refractory panels and pull them forward as mush as possible to help insertion of the back panel. 4. Place the back refractory against the back of the firebox. 5. Push the side refractory against the back to hold it in place. 6. Put the logs back in place. 7. Screw the glass back on. EMBERS KIT INSTALLATIONS : Three small plastic bags are supplied with your unit. One bag contains vermiculite to simulate ashes in the firebox, another contains lava rocks to simulate coals and the other one contains fibreglass mat which, when glowing red, resembles hot embers. 1. Place some vermiculite and lava rock on the top of the burner, keeping it well clear of any gas ports ( holes where the gas comes out of the burner ) and combustion air intake holes. CAUTIONS : Blocking gas ports with vermiculite will result in poor light up performance and delayed ignition. 2. Place four or five pieces of fibreglass mat with sizes of approximately 1” on top of the front gas ports. Place two or three pieces over each of the back gas ports. Make sure not to put to many pieces, this would result in altered flame and possible carbon deposition. OPERATING INSTRUCTIONS LIGHTING INSTRUCTIONS : 1. Open the bottom louvers of the face plate to reach the control. 2. Turn the gas valve knob to the “OFF” position and wait 5 minutes. Note : You have to depress the gas valve knob to turn from “PILOT” to “OFF” or from “OFF” to “PILOT”. 3. Turn the gas valve knob to “PILOT”. 4. Depress and hold the knob while lighting the pilot by pressing the pilot igniter button (RED button ). Keep the knob depressed for about 1 minute. Release the knob. The pilot should continue to burn by itself, if not, repeat step 4. Note : You may need to press the pilot ig...

Este manual também é adequado para os modelos :
Lareiras - 36C03U TYPE 139 (166.93 kb)
Lareiras - 36C03U TYPE 139 (166.93 kb)
Lareiras - 7000 MVRLC (166.93 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias