Cut 1 1/2” PVC pipe to correct height. Attach pipe, PTrap, and exhaust cap to plate. Glue all joints with PVC cement. Note: Must maintain a minimum 3” between exhaust outlet and air intake. HorizontalApplication 1. Attach plate to outside wall with four (4) screws. Use outdoor sealant to seal transition plate to the wall. 2. Cut 1 1/2” PVC pipe to correct length. The minimum length for this application is 9” for the exhaust and 6” for the air intake. Glue all joints with PVC cement. 24820-1-0409 Page 29 DIRECT VENT INSTALLATION INSTRUCTIONS DIRECT VENT INSTALLATION INSTRUCTIONS PVVK-24H and PVVK-48HVent Kitavailable from Empire Comfort Systems, Inc. Note: Do not glue intake or exhaust pipes to Direct Vent Adaptor for serviceability. FLUECENTEREXTERIORGRADEMANTELGASSUPPLY12”(30.5cm) MIN. SURROUNDDONOTGLUETHISPOINTDIRECTVENTKITMODEL#PVVK-24HORPVVK-48HFigure 32 HorizontalVenting EXHAUST OPENING MUST BE POINTED DOWNWARD. Figure 34 Direct Vent System Building Exterior View 45°ELBOW47.5” (1.2m) Figure 33 HorizontalVentingMaximum47.5”(1.2m)witha3”,45°elbow 3”, 45° elbow can be purchased from a local hardware store 47.5” (1.2m) Figure 35 Maximum HorizontalVenting -47 1/2” (1.2 m) Minimum HorizontalVenting -4 1/2” (11.4 cm) Page 30 24820-1-0409 DIRECT VENT INSTALLATION INSTRUCTIONS (cont.) DIRECT VENT INSTALLATION INSTRUCTIONS (cont.) Installation on Rugs and Tile If this appliance is to be installed directly on carpeting, tile, or other combustible mate rial, other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance. The base referred to above does not mean the fire-proof base as used on wood stoves. The protection is primarily for rugs that may be extremely thick and light-color tile that can discolor. EXTERIORGRADEFLUECENTER11/4” (3.2cm) MIN. 12” (30.5cm) MIN. FLOORPROTECTION Figure 36 Minimum Exterior Grade Dimension - Unit Without Pedestal FLOORPROTECTIONNOHEARTHREQUIREDEXTERIORGRADEFLUECENTER11/4” (3.2cm) MIN. 12” (30.5cm) MIN. Figure 37 Minimum Exterior Grade Dimension - Unit With Pedestal EXTERIORGRADEFLUECENTER12” (30.5cm) MIN. Figure 38 Minimum Exterior Grade Dimension - Existing Fireplace Installation 24820-1-0409 Page 31 Page 32 24820-1-0409 Available from Empire Comfort Systems, Inc. Step 1. Install foam gasket on back side of co-axial direct vent adaptor. Step 2. Attach co-axial direct vent adaptor and gasket (4 screws) to the rear of fireplace. Step 3. Attach co-axial air-inlet duct to rear of fireplace (6 screws). Step 4. Install silicone around connection between co-axial adaptor and co-axial air-inlet duct. 4 1/2” MINIMUM VENT LENGTH 3 13/16” MINIMUM TUBE LENGTH Step 5. Slide co-axial vent pipes into co-axial adaptor. Cut the PVC co-axial pipes at this time. Minimum horizontal vent length 4 1/2” (11.4 cm) Minimum tube length 3 13/16” (9.7 cm) Step 6. Direct vent co-axial venting is completed. PVVK-24H AND PVVK-48H VENT KIT 24820-1-0409 Page 33 45° ELBOW 47.5” (1.2m) Horizontal Venting Maximum 47.5” (1.2 m) with 45° elbow. 45° elbow can be purchased from a local hardware store. 47.5” (1.2m) Maximum Horizontal Venting - 47 1/2” (1.2 m) Minimum Horizontal Venting - 4” (10.2 cm) EXHAUST OPENING MUST BE POINTED DOWNWARD. Direct Vent System Building Exterior View 1 5 4 3 2 Parts List Index Number Part Number Description 1 R8887 Co-axial DV Adaptor 2 R8862 Foam Gasket 3 22616 Co-axial duct assembly 4 R8888 24” Co-axial vent pipe 5 R8954 48” Co-axial vent pipe Replacement 8-18 x 1/2” screws and silicone can be purchased from a local hardware store. PVVK-24H AND PVVK-48H VENT KIT (cont.) Page 34 24820-1-0409 GAS CONNECTION INSTALLATION INSTRUCTIONS GAS CONNECTION (Line Supply) A 3/8” Flair gas line connection is supplied in the heater GAS SUPPLY LINE TO HEATER a. Remove rubber grommet from back panel and pull out flex line through back panel. b. Connect gas supply line to flexible gas hose. Ensure that flexible gas hose is not kinked after fitting gas supply line. c. After gas supply line has been brought through from rear of heater, place rubber grommet supplied over gas line. Note: The gas supply line to the heater must be installed under conditions which will allow for easy removal of the heater from its location for servicing of the heater. For fireplace insert installations, incorporate either a copper loop into the supply line or flexible hose being used for the gas supply to the heater to allow for easy removal of the appliance. Note: Under no circumstances should the gas supply line to the appliance be installed under conditions, which would not allow for easy removal of the appliance to carry out routine inspection and service to the appliance. FLEXIBLE GAS LINE Figure 39 OPERATING INSTRUCTIONS CHECKLIST OPERATINGINSTRUCTIONSCHECKLIST BEFORE OPERATING THIS APPLIANCE, CAREFULLY PROCEED THROUGH THE FOLLOWING CHECKLIST 1. Read and understand these instructions before installing or operating this appliance. 2. This appliance ...

Este manual também é adequado para os modelos :
Lareiras - MANTIS PV-28SV50-B2H(N,P)-1 (3.48 mb)
Lareiras - MANTIS PV-28SV55-(C,G)(N,P)-1 (3.48 mb)
Lareiras - MANTIS PV-28SV55-(C,G)2H(N,P)-1 (3.48 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias