Log:
Assessments - 2, GPA: 5 ( )

Instruções de Operação Procom, Modelo PRO-COM SFE23RE-O

Fabricante : Procom
Arquivo Tamanho: 1.85 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


10. Do not run cord under carpeting. Do not cover cord with throw rugs, runners or similar coverings. Arrange cord away from traffic areas and where it will not be tripped over. 11. To disconnect heater, turn controls to OFF, then remove plug from outlet. 12. Connect to properly grounded outlets only. 13. When this appliance is installed, it must be electrically grounded in accordance with local codes with the current CSA C22.1 Canadian local codes for USA installations. Follow local codes and National Electrical Code, ANSI/NFPA NO.70 and Canadian Cord: CZ 22.2 NO.0. 14. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause electric shock, fire or damage to the heater. 15. To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces, such as a bed, where openings may become blocked. 16. This heater gets hot and it contains internal parts that sparks and arcs. Do not use it in areas where gasoline, paint, or flammable liquids are used or stored. 17. Use this heater only as described in this manual. Other uses not recommended by the manufacturer may cause fire, electric shock, or injury. 18. Avoid the use of an extension cord because it may overheat and cause a risk of fire. However if you must use an extension cord, the cord shall be No. 14AWG minimum size and rated not less than 1900 watt. The extension cord must be a three wire cord with grounding type plug and cord connector. 19. This electric fireplace heater should not be used as a drying rack for clothing. Also, do not hang Christmas stockings or decorations on or near it. 20.SAVE THESE INSTRUCTIONS. 2 CLEARANCE TO COMBUSTIBLES ELECTRICAL CONNECTION A 15 AMP, 120 Volt,60Hz circuit with a properly grounded outlet is required. Preferably, the fireplace will be on a dedicated circuit. Other appliances on the same circuit may cause the circuit breaker to trip or the fuse to blow when the heater is on operation. The unit comes standard with a 6’(1828mm) long three wire cord exiting from the rear of the fireplace. Plan the installation to avoid the use of an extension cord. If an extention cord must be used, it must be a minumum 14 AWG three wire with grounding type plug connector and rated no less than 1900 Watts.The cord shall not be more than 20 feet in length. ELECTRICAL SPECIFICATIONS SERVICE INSTRUCTIONS WARNING: Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire, electrical shock or personal injury. REPLACING LIGHT BULBS This fireplace uses four clear 120 Volt, 60 Watt, E12 socket base light bulbs (small base, chandelier candle type).The 60 Watt bulbs are located under the log set/ember bed. For convenience, if one of the bulbs burns out, it may be a good idea to replace all of the light bulbs. 1. Turn off power to the unit by unplugging the power cord. 2. Let fireplace cool if it has been operating. 3. Remove the two screws on the top corner of screen. Pull th...

Este manual também é adequado para os modelos :
Lareiras - PRO-COM SFE23RE-C (1.85 mb)
Lareiras - PRO-COM SFE23RE-DO (1.85 mb)
Lareiras - PRO-COM SFE23RE-W (1.85 mb)
Lareiras - PRO-COM SFE33RE-C (1.85 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias