Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação Hearth and Home Technologies, Modelo GO330MTCH

Fabricante : Hearth and Home Technologies
Arquivo Tamanho: 5.18 mb
Arquivo Nome : 4004_300.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


• Replace component parts of the chimney and fireplace as specified by the professionals. • Ensure all joints are properly engaged and the chimmney is properly secured. • Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame pattern. • Do not use a blower insert, heat exchanger insert or other accessories not approved for use with this appliance. B. Tools and Supplies Needed Tools and supplies normally required for installation: Pliers Phillips screwdriver Tape measure Crescent wrenches Gas shutoff valve Non-corrosive leak check solution 3/4 in. wrench, 7/16 in. wrench WARNING Fire Risk Exhaust Fumes Risk • Do NOT use this appliance as a “vent-free heater. The flue must be permanently open according to Tables 1 and 2. C. Important! • Do not remove any of the attached metal plates, which contain important safety and operating information. • Keep the appliance area clear and free of all combustible materials, gasoline and other flammable vapors and liquids. • Any safety screen or guard removed during servicing must be replaced before operation. • A qualified service technician must perform installation and repair. The appliance should be inspected and cleaned annually by a qualified service technician. More frequent cleaning may be required due to excessive lint, dust, pet hair, etc. It is imperative that the control compartments, burners and air passageways are unobstructed during operation. • This appliance must have a screen in place while the appliance is in operation and, unless other provisions for combustion air are provided, the screen shall have an opening for introduction of combustion air. • Solid fuels shall not be burned in a fireplace where a decorative appliance is installed. • If glass doors are present, the glass doors must be fully opened while appliance is in operation. WARNING Fire Risk Explosion Risk Verify inlet pressures. • High pressure may cause overfire condition. • Low pressure may cause explosion. Install regulator upstream of valve if line pressure is greater than 1/2 psig. WARNING Do NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. D. Appliance Certification This appliance has been evaluated by Omni in accordance with the requirements of Ansi Z21.84-2004 Standard for Decorative Log Sets for Installation in Wood Burning Fireplaces. Installation and the provisions for combustion and ventilation air must conform to the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the CSA B149.1, Natural Gas and Propane Installation Code. E. Gas Supply Connection A 3/8 in. flared fitting has been installed on the gas valve inlet at the factory. Ensure fittings are of the appropriate size and type on the gas line connection. If the tubing has to be cut to length be sure to use the proper cutting and flaring tool. Also, be careful not to crimp the tubing while bending. If the tubing becomes crimped, do not use for installation. Gas resistant pipe compound must be used on all threaded male connections to ensure a tight seal. F. Gas Pressure Proper input pressures are required for optimum appliance performance. Gas line sizing requirements need to be made following NFPA51. • Gas Supply Pressure: Minimum inlet gas supply pressure must be 7.0 in. W.C. for natural gas. The gas line supplying the appliance must be sufficient size to furnish the appropriate supply pressure to the appliance while operating in the “High” setting. • Pressure tap screws must be closed before turning gas on to the appliance. • Gas Line Pressure Test: Perform pressure test according to state and local code (if pressure exceeds 1/2 in. psi (3.5 kPa)) before appliance is connected. Be sure to release air pressure from the gas line before connection is made to the appliance. Excessive pressure will damage the gas control and may cause a gas leak. • Gas Leak Test: Make sure the gas connections are tight. Turn on the gas and coat each joint with a non-corrosive gas leak check solution. Air bubbles will form indicating any leaks. DO NOT USE A FLAME OR ANY TYPE OF IGNITION SOURCE TO CHECK FOR LEAKS. All leaks must be corrected before proceeding with installation. • The appliance must only be installed in a solid-fuel burning fireplace with the flue damper clamped open according to Tables 1 and 2. The fireplace must be constructed of non-combustible material. • The minimum permanent free opening (in square inches) that must be provided by the fireplace chimney or damper to vent the flue gases is provided in Tables 1 and 2. If the free opening is smaller than the specified area, do not use this appliance. • The damper must be removed or fixed in a manner in which will secure it open. Some jurisdictions require the damper to be removed or permanently welded fully open. Check with state and local codes. • Be sure that the chim...

Este manual também é adequado para os modelos :
Lareiras - GO318MTCH (5.18 mb)
Lareiras - GO24MTCH (5.18 mb)
Lareiras - GO30MTCH (5.18 mb)
Lareiras - GO324MTCH (5.18 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias