Log:
Assessments - 4, GPA: 3.8 ( )

Instruções de Operação Breckwell, Modelo P24FSA

Fabricante : Breckwell
Arquivo Tamanho: 462.74 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


A hinged door oovers the panel during normal operation. The on-off switch turns the blowers on. The “auger" button activates the automatic feed system. When the green light is on, there is power to the auger circuit. The auger will not begin feeding pellets until the firebox has warmed up to a preset temperature. In case of a power outage lasting more than three to six seconds, this button must be pushed to re-engage the auger. There are six fuel feed settings. On “LOW”, the feed rate is approximately 0.75 to 1.5 lb. per hour. On “MAX” the feed rate is approximately 4.25 to 4.75 lbs. per hour. PAGE 7 CAUTION: The "MAX” setting is designed for temporary use only. If used r for extended periods, It can shorten the life expectancy of the unit’s components. Avoid use at this setting for more than one or two hours at a time. The convection blower speed varies directly with feed rate. The “High Fan” switch overrides this variable speed function. It will set the convection blower speed to high at any feed rate setting. The “Manual Feed” switch allows you to add fuel to the bum pot automatically. CAUTION: Do not use this control during normal operation as it could smother the fire and lead to a dangerous condition (see section 3.92 a). During normal operation, this switch should be in its center position, neither on “HIGH FAN" or "MANUAL FEED”. be more open. Through trial and error, you will find the best settings. Consult your dealer if you need help. NOTE: On “LOW”, damper should be out approximately 1/8M/4". If damper is out too far, it can cause the fire to go out. 3.7 REFUEUNG We recommend that you not let the hopper drop below V* full. KEEP HOPPER LID CLOSED AT ALL TIMES EXCEPT WHEN REFILLING. DO NOT OVERFILL HOPPER. A too) has been provided to help with the following functions: a. Stir pellets in hopper—Unlike liquids in a tank, pellets do not drain evenly into the auger. Bridging across the opening can occur. Pellets can hang up on the sides of the hopper. Occasionally “stirring" the hopper can help. NOTE: To help prevent bridging of pellets common wax paper can be rubbed on the sidewalls and bottom of the hopper. b. Cleaning heat exchanger tubes—see instructions, section 4.2. c. Scrape ashes from bum pot. 3.5 OPTIONAL THERMOSTAT A remote thermostat may help you maintain a constant house temperature automatically. A millivolt'thermostat is required. When engaged, the stove will automatically switch between two settings. When warm enough, it will switch to “LOW", which also slows the convection blower. If the house then cools below your thermostat setting it will switch to the feed rate of your knob setting with a maximum rate of “D". The thermostat should be installed by a qualified sen/ice person. NOTE: When using the thermostat, it is important to set your damper control rod at approximately halfway between a "LOW” burn setting and your higher bum setting. 3.9 SHUT DOWN PROCEDURE Turning your Breckwell stove off is a matter of pressing the on/off control panel switch to off. The blowers will continue to operate until internal firebox temperatures have fallen to a preset level. 3.91 SAFETY FEATURES 3.6 DAMPER CONTROL The damper control rod on the stove's lower left side adjusts the combustion air. This control is necessary due to the varied burn characteristics of individual installations, different pellet brands and pellet feed rates. It allows you to improve the efficiency of your stove. Providing correct combustion air will reduce the frequency of cleaning your glass door and prevent the rapid build-up of creosote Inside your stove and chimney. You should adjust the damper based on the fire’s appearance. A low, reddish, dirty fire can be improved by pulling the damper out slightly. A “blow torch" fire can be improved by pushing the damper in a bit. As a general rule, on lower feed rate settings, the damper should be in farther. On higher feed rates, the damper should a. If there is a power outage longer than a few seconds, the auger will not operate once power is restored. This prevents pellets from being fed to a non-burning bum pot. Pressing the auger button on the panel control will reactivate the auger circuit. The blowers will come on when power is restored to evacuate the combustion chamber of gases and stay on until off switch is pushed. b. In case of a malfunctioning convection blower, a high temperature thermodisk will automatically shut down the auger, preventing the stove from overheating. When stove has cooled, restart as instructed in sections 3.2 and 3.3. c. If the combustion blower fails, an air pressure switch will automatically shut down the auger. NOTE: Opening the stove door or pedestal ash door (P24FSA model only) during operation will cause enough pressure change to activate the air switch. Closing the door and depressing the “auger” button will restart the system. PAGES 3.92 OPERATING SAFETY PRECAUTIONS a. If you notice a smoldering fire (burn pot f...

Este manual também é adequado para os modelos :
Lareiras - P24FSL (462.74 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias