Log:
Assessments - 4, GPA: 4 ( )

Instruções de Operação GN National Electric, Modelo GP)-1

Fabricante : GN National Electric
Arquivo Tamanho: 2.59 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


The base referred to above does not mean the fire-proof base as used on wood stoves. The protection is primarily for rugs that may be extremely thick and light-color tile that can discolor. EXTERIORGRADEFLUECENTER11/4” (3.2cm) MIN. 12” (30.5cm) MIN. FLOORPROTECTION Figure 27 Minimum Exterior Grade Dimension - Unit Without Pedestal FLOORPROTECTIONNOHEARTHREQUIREDEXTERIORGRADEFLUECENTER11/4” (3.2cm) MIN. 12” (30.5cm) MIN. Figure 28 Minimum Exterior Grade Dimension - Unit With Pedestal Page 24 22618-4-1106 DIRECT VENT INSTALLATION INSTRUCTIONS (cont.) FLUECENTER12” (30.5cm) MIN. EXTERIOR GRADE Figure 29 Minimum Exterior Grade Dimension - Existing Fireplace Installation 22618-4-1106 Page 25 Page 26 22618-4-1106 GAS CONNECTION INSTALLATION INSTRUCTIONS GAS CONNECTION (Line Supply) A 3/8” Flair gas line connection is supplied in the heater GAS SUPPLY LINE TO HEATER a. Remove top panel from heater by lifting top panel. b. Remove front and rear panel. c. Remove rubber grommet from back panel of heater and insert gas supply line through back panel of heater. d. Connect gas supply line to flexible gas hose. Ensure that flexible gas hose is not kinked after fitting gas supply line. e. After gas supply line has been brought through from rear of heater, place rubber grommet supplied over gas line and install panels. Note: The gas supply line to the heater must be installed under conditions which will allow for easy removal of the heater from its location for servicing of the heater. For fireplace insert installations, incorporate either a copper loop into the supply line or flexible hose being used for the gas supply to the heater to allow for easy removal of the appliance. Note: Under no circumstances should the gas supply line to the appliance be installed under conditions, which would not allow for easy removal of the appliance to carry out routine inspection and service to the appliance. FLEXIBLE GAS LINE Figure 30 OPERATING INSTRUCTIONS CHECKLIST BEFORE OPERATING THIS APPLIANCE, CAREFULLY PROCEED THROUGH THE FOLLOWING CHECKLIST 1. Read and understand these instructions before installing or operating this appliance. 2. This appliance is should be installed and repaired by a fully qualified service person who must be familiar with the installation of the Mantis Power-Vent High-Efficiency Fireplace. 3. Installers who are not familiar with the installation of this appliance should contact Empire Comfort Systems, Inc. prior to installing the appliance to avoid creating hazardous operating conditions. 4. Check and inspect the appliance for gas leaks. In the event of gas leaks, cut off the gas supply to the heater immediately and call your gas supplier or installer. 5. Check and verify that all flue venting combustion air intakes and flue outlets are unobstructed. 6. Refer to pages 19 to 22 for Single Flue pipe and pages 23 to 25 for Co-axial Flue installations. Check that correct flue pipe and cap has been fitted in line with the manufacturer’s specifications as illustrated in this manual pages 11 to 25. 7. Do not use alternative Flue or cap on installation other than that specified in this manual - otherwise heater will malfunction and cause hazardous operating conditions and will void the manufacturer’s warranty. 8. Check and verify that flue pipe connection to the appliance when using single 1 1/2” flue pipe installation is correctly installed and secured in line with instruction in this manual, Pages 19 to 22. 9. Prior to operating the appliance, check for dust or debris on the burners. Refer to Page 37, Figure 47. 10. Check and verify that logs are place correctly as per instructions on Pages 16 to 17 of this manual. If logs are incorrectly positioned, it can create a hazardous situation, and in most instances, the heater will not operate correctly. 11. Do not light heater without logs installed, as heater will not operate properly. 12. Check and verify prior to starting the appliance, that all panels are secured in place and that the main door has been locked in position. 13. After verifying and checking all the above points, proceed to lighting instructions. Refer to pages 28 to 29. 22618-4-1106 Page 27 LIGHTING INSTRUCTIONS 1. Main Electrical power supply must always be switched on to the unit with the two burner switches in the off position (up) before lighting the heater. 2. Turn on main gas supply. 3. Verify that main electrical supply is switched on by checking the 115VAC power status display (Figures 32 and 33) indicator is on. 4. Burner selection: select low burn (front burner), medium burn (rear burner), or high burn (both burners). Low burn switch (Figure 32) controls the front burner only. Medium burn switch (Figure 33) controls the rear burner only. When both switches are down, they will activate both the low and medium burners, which is the high setting. 5. Heater operating LED sequence (Front Display Panel). Before starting ensure that the power L.E.D (Figure 34A) is on and burner switches are off. Sw...

Este manual também é adequado para os modelos :
Lareiras - BP)-1 (2.59 mb)
Lareiras - CP (2.59 mb)
Lareiras - GN (2.59 mb)
Lareiras - PV-28SV50 (2.59 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias