Log:
Assessments - 6, GPA: 3.5 ( )

Instruções de Operação Monessen Hearth, Modelo STANDARD SERIES CF6500-CMN

Fabricante : Monessen Hearth
Arquivo Tamanho: 598.98 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


The following paragraphs detail the kit options available for use with the appliances covered in this manual. These outstanding optional items can be added individually or in sets of two or more to customize your appliance to fit your homes unique needs. Kit model numbers are provided on page 14 along with descriptive illustrations. The appliances covered in this manual are heater rated and produce a great deal of heat. Decorative brass trim pieces and hoods may tarnish because of their proximity to the heater opening and front face. Tarnishing of these pieces is normal, unavoidable and should be expected. Forced Air Kit The FAB-1100 assembly (Figure 26)provides a forced air circulation feature for your appliance. This kit mounts directly into the lower intake chamber, behind the blower shield, with an electrical connection made at the receptacle provided (Figure 27 ). The appliance must have an independent 120Vac power line incorporated at the time of installation. Place the blower against the back wall of the appliance within its chamber behind the blower shield. The blower shield has to be removed for blower insertion and replaced before the installation is complete. The instructions provided with the blower kit detail all wiring and operation concerns. The blower shield located at the back of the appliance lower control compartment isolates the blower chamber from the control area in front. The blower shield is secured in place with two screws that must be removed and retained for reuse. Pull the bottom of the shield forward and bring the top down to remove the shield horizontally, flat against the appliance bottom and below the gas controls, piping, and wiring. The blower may be inserted around the right side of the gas controls after any intervening connecting field installed gas line has been re-routed or removed. Place the blower within the chamber, (Refer to the diagrams provided with the blower Kit) and reinstall the blower shield. Ensure the blower wire is routed through the notch in the bottom edge of the shield. Access to the blower chamber at the rear of the lower control compartment in CF-5500 appliances is restricted due to its compact design, by the interfering tubing of the gas controls assembly. To provide clearance for the blower, the spudplate assembly must be lifted up slightly to allow the blower to be inserted into its chamber under it. To allow the spudplate to be lifted, remove the four screws securing it to the appliance firebox floor. The screws must be accessed from within the firebox. Refer to Page 5 and Step 11 for door removal and replacement, refer to Step 9 for log removal, handling and placement instructions. NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. Figure 26 Grounded to Appliance Blower Motor Motor Plug Receptacle 120V Appliance Junction Box Figure 27 Wall Switch Kit An optional wall switch kit can be installed along with all CF appliances. The kit consists of a standard UL wall switch with cover plate. This kit provides for remote (wall) operation of the appliance. Replace the wall switch and cover plate of this kit with the components of the RCK and you can have true remote control of your direct vent appliance, turning it on and off from your favorite easy chair. The wall switch kit should be installed along with the appliance. Refer to Figure 15 and Step 7 for detailed installation instructions. Rocker Switch Switch Kit An optional rocker switch kit can be installed directly on all CF series appliances to provide for On and Off operation in lieu of a wall switch. This kit is designed to install in the lower control compartment out of view and is perfe...

Este manual também é adequado para os modelos :
Lareiras - STANDARD SERIES CF5500-CMN (598.98 kb)
Lareiras - STANDARD SERIES CF5500-CMN (598.98 kb)
Lareiras - STANDARD SERIES CF5500-CMN (598.98 kb)
Lareiras - STANDARD SERIES CF5500-CMN (598.98 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias