Log:
Assessments - 4, GPA: 4.5 ( )

Instruções de Operação Heat & Glo LifeStyle, Modelo GAS FIREPLACE SLR (COSMO)

Fabricante : Heat & Glo LifeStyle
Arquivo Tamanho: 3.22 mb
Arquivo Nome : COSMO.pdf
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


FIREBOX BOTTOMFIREBOX BOTTOM REMOTE CONTROL RECEIVER IPI CONTROL MODULE BATTERY TRAY LOWER ACCESS PANEL Figure 12.1 Valve Cavity Heat & Glo • SLR • 2143-900 Rev. B • 7/08 • 46 Heat & Glo • SLR • 2143-900 Rev. B • 7/08 Figure 12.2 Intellifi re Pilot Ignition (IPI) Wiring Diagram with Wall Switch or Thermostat Figure 12.3 Junction Box Detail NOTICE: DO NOT wire 110 VAC to wall switch. E. Junction Box Installation 1. Remove the two screws that hold the junction box bracket to the right corner of the fi replace. 2. Remove the one screw that secures the junction box to the junction box bracket. 3. Route the wire through the strain relief in the outer wrap and down through the strain relief on left side of the junction box bracket and up through the right strain relief. See Figure 12.3. 4. Make the connection inside the junction box to the 120V wire. Connect green to the ground nut, black to black and white to white. 5. Reattach junction box to junction box bracket with one screw. 6. Reattach the junction box bracket to the appliance with two screws. TRANSFORMER 3 VAC PLUG IN BLACK RED BATTERY PACK THERMOSTAT WIRE ASSEMBLY WIRES (TO BROWN) ORANGE GREEN VALVE WHITE ORANGE IGNITION MODULE 3 VAC INTERMITTENT PILOT IGNITOR HOT NEUTRAL I S GROUND TO FIREPLACE CHASSIS NOTE: 1. Ignition module, valve, pilot, and wall switch operate on 3 volts. 120 VAC is required at junction box unless equipped with battery back-up. JUNCTION BOX BRACKET D. Electrical Service and Repair WARNING! Risk of Shock! Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. WARNING! Risk of Shock! Replace damaged wire with type 105° C rated wire. Wire must have high temperature insulation. NOTE: There is an alternative access to the junction box. This can be accessed by removing the valve assembly. See Figure 11.2. In the event that the junction box needs to be accessed or installed after fi nish methods have been applied, access is possible by removing the valve assembly. See Fig. 11.2. Bend the top heat shield back and remove the one screw that secures the junction box to the bracket. Ensure the heat shield is bent back so that it is positioned above the junction box. .. .. 113 Finishing A. Framing and Finishing Instructions WARNING! Risk of Fire! Comply with all minimum clearances to combustibles as specified. Framing closer than the minimums listed must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc.) Failure to comply could cause fire. Finishing Instructions It is important to follow the framing and finishing instructions to ensure proper placement of fi replace into the surrounding framing/fi nishing materials. Wall sheathing materials 1/2 in. thick are specifi ed in this installation manual to properly align with the factory- installed non combustible material WARNING! Risk of Fire! DO NOT, under any circumstances, remove the factory-installed noncombustible board or cover it with any combustible material, such as: • Drywall (gypsum board) • Plywood • Or other materials that do not meet the ASTM E 136 Non-combustibility standard. See specification below Failure to comply with these instructions may cause a fire or cause the appliance to overheat. Non-Combustible Materials Specification Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof. Materials that are reported as passing ASTM E 136, Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 .C and UL763 shall be considered non-combustible materials. Setting the Fireplace into the Framing Unlike many traditional, single-sided Heat & Glo fireplaces, this fireplace is recessed into surround framing. The left and right nailing tabs were designed for the SLR model as a means to ensure the fireplace is recessed to the correct location within the framing materials. 1. Bend three nailing tabs away from fi replace 180 degrees on both left and right nailing tabs. Do not adjust the column standoffs. See Figure 13.1 and Figure 13.2. 2. Screw each nailing tab to the adjoining framing material. Ensure that the 1” air space clearance is maintained on the sides of the fireplace. See Figure 13.3. Figure 13.1 Nailing Tabs Shipping Position Factory-Installed Non-Combustible Board Top Flange NAILING TABS Figure 13.2 Nailing Tabs Installation Position Factory-Installed Non-Combustible Board Top Flange DO NOT ADJUST Figure 13.3 Front Side Finishing Detail FRAMING 1.00 in. 1/2 in. BUILDING MATERIAL 1-9/16 in. Heat & Glo • SLR • 2143-900 Rev. B • 7/08 WARNING! Risk of Fire! Maintain specified air space clearances to combustibles. Failure to comply with these instructions may cause a fire or cause the appliance to overheat. Ensure that the one inch back clearance and one inch side clearances are maintained. NON-COM...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias