|
Facilidade de uso
. See Figure 32, Connection A. 9. The other fan control wire has a 1/4” male terminal. Attach this terminal to the open terminal on the blower power cord. See Figure 32, Connection B 10. Route the wires away from moving parts of the blower assembly and retain wires together near the blower motor using the plastic purse clip provided. 11. To complete the installation, plug the power cord into the junction box receptacle at the right rear corner of the firebox outer wrap. See Figure 30. 12. If room permits, the power cord can be located from the outside of the unit looking through the junction box access hole (with the junction box removed), then plug up the power cord before reinstalling the pre-wired junction box. 13. Once all connections are made electrically, it is recommended that you test the blower fan control operation by turning on power to the blower (Caution: 110 Volt). Then apply heat to the fan control switch inside the firebox with a lighter or match until blower is activated. Once blower is activated, check for proper operation. Do not place hands near blower assembly or other wiring while power is on. 14. Replace blower access plate and/or reinstall the brick liner panels if provided. 15. This completes the installation of the optional FBB5 Blower kit accessory. Note: This blower is equipped with a heat activated fan control switch. Blower will operate when the firebox warms up, and will turn off automatically when the firebox cools down. REAR COVER PANEL MAY BE REMOVED TO INSTALL BLOWER REINSTALL COVER AFTER BLOWER IS INSTALLED Figure 28 FAN CONTROL SWITCH LOCATION FAN CONTROL WIRES Figure 29 Figure 30 BLOWER POWER CORD Page 14 23200-0-1206 Blower Motor The blower motor does not have oiling holes. Do not attempt to oil the blower motor. Blower Wheels The blower wheels will collect lint and could require periodic cleaning. If the air output decreases or the noise level increases, it indicates a dirty blower wheel. Remove fan and clean blower wheels. Warning: Unplugging of blower accessory will not stop the heater from cycling. To turn off gas to the heater (millivolt model): push in gas control knob slightly and turn clockwise to “OFF.” Do not force. To turn off gas on direct ignition model, turn gas line valve to “OFF.” 1 FBB5 BLOWER ASSEMBLY COMPLETE 2 R8199 FAN CONTROL SWITCH 1 2 A B 110 VOLT AC JUNCTION BOX WHITE FAN SWITCH BLACK FAN/MOTOR ASSEMBLY Figure 31 Figure 32 JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, CITY AND STATE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THAT MAIN POWER SUPPLY IS DISCONNECTED. THE APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL CODE ANSI/NFPA 70 (LATEST EDITION) A factory installed junction box is located on the lower right hand side of the firebox. Wiring must be fed...
Este manual também é adequado para os modelos :Lareiras - VFD36FB2CL-1 (4.64 mb)
Lareiras - VFD36FB2DF-1 (4.64 mb)
Lareiras - FD42FB2DF-1 (4.64 mb)
Lareiras - VFD32FB0F-1 (4.64 mb)