Log:
Assessments - 3, GPA: 4.3 ( )

Instruções de Operação Dimplex, Modelo (SP5) SP520

Fabricante : Dimplex
Arquivo Tamanho: 960.6 kb
Arquivo Nome : 07959184-5940-4dfb-b070-fcd371d4ee94.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


The heater should not be connected until the instruction leaflet is read fully. Recessed Installation Please note that this appliance can also be wall-mounted so that it is recessed. This can be installed in a large fireplace opening or a purpose built wall. See Table 1 for size of recess required and hole fixing dimensions and Fig. 5a. This fireplace insert does NOT require venting. In order to ensure it’s future safety in use, it is essential that this fire is securely fixed to the wall. IT IS IMPORTANT THAT THE FIXING DEVICE CHOSEN IS APPROPRIATE TO THE WALL MATERIAL TO WHICH THE FIRE IS BEING FIXED. SOME MODERN INTERNAL BUILDING MATERIALS ARE VERY LOW DENSITY BLOCK AND REQUIRE SPECIALIZED FIXING DEVICES TO PROVIDE A SAFE,SECURE INSTALLATION. The installation of this fire should be carried out by a competent person. If in doubt please consult your local builder. This section provides step by step instructions for selecting a location and preparing the site to install the fireplace into the following: Existing Fireplace 1. Make sure that the fire is located on a flat surface. 2. Seal all draughts and vents to prevent chimney debris from falling onto the Fireplace Insert. Do not install into an existing fireplace that is prone to dampness. 3. Remove the fire front panel by following the steps as outlined in ‘Lamp Replacement’ sections. 4. Locate the 4 fixing holes, position the fire accordingly, and firmly fix the appliance to the wall using the appropriate screws - see Fig. 5a. 5. Replace the front panel. New Support Structure Construction When planning where to position your purpose built support structure the following steps must be observed: 1. Place the fire in the desired location to see how it will look in the room. 2. Mark the desired location for the new support structure in the room and store the fire in a safe, dry and dust free location. 3. Using timber studs to support the fire, devise and construct a suitable means of supporting the product within the wall partition and provide electrical power for the fire to be HARD wired. For recommended sizes of height, width and depth of opening for recess and hole fixing dimensions for each model - see Table 1 and Fig. 5a. 4. When the structure is complete, remove the front panel of the fire by following the steps as outlined in ‘Lamp Replacement’ sections. 5. Locate the 4 fixing holes, position the fire accordingly, and firmly fix using the appropriate screws. 6. Replace the front panel. TABLE 1 Models ABXYZ SP420 871 570 847 646 115 SP520 1160 560 1143 640 146 SP920 914 565 895 676 150 NOTE: The appliance should be HARD wired to an electrical power outlet when placed in a recessed installation. Please consult a qualified electrician for appropriate wiring requirements. Manual Operation - SP420 & SP920 The switches are located at the bottom right side of the heater. The Standby Switch (Switch S1) must be first turned ‘ON’ and the AUTO/MAN (Switch S2) switch set to ‘MANUAL’ to operate the manual controls - see Fig. 6. Note : When the fire is put in Manual mode the first time the flame effect will come on indicated by the Bottom neon coming on for 3 seconds - see Fig. 7. Manual Operation - SP520 The switches are located at the bottom right side of the heater -see Fig. 6. Remote Operation The standby switch (S1) must first be turned ‘ON’ (and the ‘AUTO/MAN’ Switch turned to ‘AUTO’ - SP420 & SP920). Note: It takes some time for the receiver to respond to the transmitter. DO NOT PRESS the buttons more than once within two seconds for correct operation. Manual & Remote Operation Setting Operation Setting Flame Effect only Press the ‘ I ’ button (Switch 3) Top Neon Flame Effect & Heat On Press the ‘ I ’ button again (Switch 3) Bottom Neon The Standby switch must first be turned ‘ON’ to operate the heater manually or by remote control. Note: It takes some time for the receiver to respond to the transmitter. DO NOT PRESS the buttons more than once within two seconds for correct operation. To go to the previous settings press the O button. Pressing the O button on the remote turns off the light & heat settings. To resume press the I button until the desired setting is reached - see Fig. 8. To increase or decrease the brightness of the flames, use the dimmer button or the button on the Remote Control. The heat setting will remain the same. To turn off the power the Standby Switch must be turned ‘OFF’. Lamp Replacement - SP420 WARNING – ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE REMOVING LAMPS. Warning -The lamps reach high temperatures during operation. For this reason, allow the lamps to cool down after switching off the appliance. The front panel will need to be removed in order to change lamps –see Fig. 10. Warning - The front panel is heavy and easily damaged. The front panel is fixed with 4 spring loaded pins (see ‘a’ in Fig. 9) and is supported at the top by the chassis. To gain access to lamps please apply the following procedure: While holding the fro...

Este manual também é adequado para os modelos :
Lareiras - (SP4) SP420 (960.6 kb)
Lareiras - (SP9) SP920 (960.6 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias