Log:
Assessments - 5, GPA: 4.4 ( )

Instruções de Operação Dimplex, Modelo DF2426GB

Fabricante : Dimplex
Arquivo Tamanho: 657.07 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


· Increase the separation between the equipment and the receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 2 · Consult the dealer or an experienced radio/TV technician for help. Operation is subject to the following two conditions: (1) this device may not cause interference and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Model And Serial Number Information If you have any questions about our products please have the product model and serial numbers available upon calling Dimplex customer service. To locate the model and serial number see below. (Figure 1) 3 Figure 1 Model Number Model Number Part Number Serial Number NOTE 1: A 15 Amp, 120 Volt circuit is required. A dedicated circuit is preferred but not essential in all cases. A dedicated circuit will be required if, after installation, the circuit breaker trips or fuse blows on a regular basis when the heater is operating. Additional appliances on the same circuit may exceed the current rating of the ! circuit breaker. WARNING: Ensure the power cord is not installed so that it is pinched or against a sharp edge and ensure that the power cord is stored or secured to avoid tripping or snagging to reduce the risk of fire, electric shock or injury to persons. Construction and electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the risk of fire, electric shock and injury to persons. Do not attempt to wire your own new outlets or circuits. To reduce the risk of fire, electric shock or injury to persons, always use a licensed electrician. Site Selection And Preparation This section provides instructions for selecting a location and preparing the site to install the fireplace into your Dimplex mantel surround. 1. Select a suitable location that is not susceptible to moisture and is away from drapes, furniture and high traffic. 2. For ease of electrical hook up you may wish to locate the fireplace near an existing outlet. (Refer to NOTE 1) 3. Store the fireplace in a safe dry and dust free location. ! NOTE: The dimensions of the fireplace are 26 inches (660.5 mm) wide X 18 7/8 inches (479.5 mm) high X 9 1/4 inches (235 mm) deep. The fireplace does not require any additional venting. Fireplace Installation 1. Install the fireplace assembly into the mantel. (Refer to mantel assembly instructions) ! NOTE 1: A15Amp,120Voltcircuitisrequired. Adedicatedcircuit ispreferredbutnotessentialinallcases. Adedicatedcircuitwillbe required if, after installation, the circuit breaker trips or fuse blows on a regular basis when the heater is operating. Additional appliances on the same circuit may exceed the current rating of the circuit breaker. 4 IMPORTANT: If not using a Dimplex mantel, the fireplace must be installed in an enclosure with the following MINIMUM internal/ opening dimensions. (Figure 2) New Wall Construction 1. Select a suitable location that is not susceptible to moisture and is away from drapes, furniture and high traffic. 2. Place the fireplace in the desired location to see how it will look in the room. 3. Mark the desired location on the floor and store the fireplace in a safe, dry and dust free location. 4. Use studs to frame an opening of 24 1/2 inches (622 mm) wide X 18 1/4 inches (463.6 mm) high X 8 7/8 inches (225.5 mm) deep. Option #1 - The power cord can be lead from behind the trim and along the wall to an outlet near the fireplace. Option #2 - A new outlet can be installed inside the new frame construction. Plug the unit into a 15Amp/120Volt outlet. If the cord does not reach, you may use an extension cord rated for a 5 Figure 2 18 1/4” (463.6 mm) 24 1/2” (622 mm) 8 7/8” (225.5 mm) minimum of 1875 watts. Option #3 -Hardwire 1. Wireadedicated,properlyfusedcircuitwith120Volt, 15Amp rating. Allow up to 8 feet of service cable for connecting power supply to junction box on fireplace when installing after finishing wall. CAUTION: Use two conductor, non-metallic sheath cable with ground wire (3 wires total) for the incoming power supply on fireplace inserts. Use appropriate wire to meet local and national electrical codes for rated power consumption. 2. Remove the outer jacket and strip the individual conductor from the end. 3. Loosen the screw securing the junction box cover and remove the cover. 4. Take the cables out from the junction box, loosen the two wire twist nuts and remove the cord set. (Figure 3) Figure 3 Figure 4 5. Route the power supply wire through the knockout on supplied alternative junction box cover and secure with a wire clamp (not supplied). (Figure 4) 6. Connect the black wire (live) from the unit to the black wire from 6 power supply. (Figure 4) 7. Connect the white wire (neutral) from the unit to the white wire from power supply. (Figure 4) 8. Connect the green wire (ground) from the unit to the green wire from power supply. (Figure 4) 9. P...

Este manual também é adequado para os modelos :
Lareiras - DF2426SS (657.07 kb)
Lareiras - DF2550 (657.07 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias