Log:
Assessments - 2, GPA: 5 ( )

Instruções de Operação Superior, Modelo DIRECT VENT SSDVT-4035CNM

Fabricante : Superior
Arquivo Tamanho: 1.77 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Interrupteur ON/OFF FFONIISPNOLORTNOCRETINGIVue de face MAINTENANCE SCHEDULE Annually (Before the onset of the Burning Season) MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDURE Inspecting/Cleaning Burner, Logs and Controls Qualified Service Technician Inspect valve and ensure it is properly operating. Check piping for leaks. Vacuum the control compartment, fireplace logs and burner area. Check Flame Patterns and Flame Height Qualifi ed Service Technician Refer to Figure 10 on Page 11 and verify the flame pattern and height displayed by the appliance conforms to the picture. Flames must not impinge on the logs. Ensure flames are steady (not lifting or fl oating). Inspecting/Cleaning Pilot and Burner Qualifi ed Service Technician Refer to Figure 12 (SIT Millivolt), Figure 13 (Honeywell Millivolt) or Figure 14 (Electronic) on Page 12. Remove any surface build-up on pilot and burner assembly. Wipe the pilot nozzles, igniter/fl ame rod and hood. Ensure the pilot fl ame engulfs the fl ame sensor as shown. Checking Vent System Qualified Service Technician Inspect the vent system at the top and at the base (within the firebox) for signs of blockage or obstruction. Look for any signs of dislocation or deterioration of the vent components. Note: Excessive condensation can cause corrosion of caps, pipe & fittings (excessive condensation can be caused by long lateral runs, too many elbows and/or exterior portions of the system being exposed to cold weather). Also inspect wall straps or plumbers's tape to ensure it is secure and in place. Appliance Checkout Qualified Service Technician Perform the appropriate appliance checkout procedure detailed in this manual. Replacing Rockwool Ember Materials Homeowner/Qualifi ed Service Technician Remove old ember materials (rockwool) and vacuum the ember placement area. Place new embers as described and shown in Figures 8 & 9. Periodically (After the Burning Season) MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDURE Cleaning Firebox Interior Homeowner Carefully remove logs, rockwool and volcanic stone. Vacuum out interior of the firebox. Clean firebox walls and log grate. Replace logs, rockwool, and volcanic stone as detailed in this manual. Check Flame Patterns and Flame Height Homeowner Refer to Figure 10 on Page 11 and verify the flame pattern and height displayed by the appliance conforms to the picture. Flames must not impinge on the logs. Checking Vent System Homeowner Inspect the vent system at the top and at the base (within the firebox) for signs of blockage or obstruction. Look for any signs of dislocation of the vent components. Cleaning Front Glass Enclosure Panel Homeowner Clean as necessary following the directions provided in this manual. DO NOT TOUCH OR ATTEMPT TO CLEAN GLASS WHILE HOT. TROUBLESHOOTING TROUBLESHOOTING s in the “ON” position. Important: Valve system troubleshooting should only be accomplished by a qualifi ed service technician. TROUBLESHOOTING GUIDE - MILLIVOLT GAS CONTROL SYSTEM SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark igniter will not light pilot afterrepeated triggering of igniter button. A. Defective igniter(no spark at electrode). Check for spark at electrode and pilot; if no spark andelectrode wire is properly connected, replace igniter. WARNING: if the pilot will not light after 1 minute of attempting, waitfor at least 5 minutes for gas toclear before attempting again. B. Defective or misaligned electrode at pilot(spark at electrode). Using a match, light pilot. If pilot lights, turn off pilotand trigger the igniter button again. If pilot lights, animproper gas mixture caused the bad lighting and alonger purge period is recommended. If pilot will notlight – check gap at electrode and pilot – should be 1/8" to have a strong spark. If gap measures 1/8", replacepilot (see Figure 12 or 13 on Page 12). C. Gas supply pressure errant. Check inlet gas pressure. It should be within the limitsas marked on the rating plate. D. Pilot orifi ce plugged. Clean or replace pilot orifi ce. 2. Pilot will not stay lit aftercarefully following the lightinginstructions. A. Defective pilot generator(thermocouple). Check pilot fl ame, it must impinge on thermocouple (see Figure 12 or 13 on Page 12). Clean and/oradjust pilot for maximum flame impingement on thermocouple. Ensure that the connection betweenthe valve and thermocouple are tight and secure. 3. Pilot burning, no gas to burner, Valve knob “ON,” and the (standard) burnerOFF/ON switch is “ON." Read important note below. A. Wall switch or wires defective. Check wall switch and wires for proper connections. Jumper wire across terminals at wall switch, if burnercomes on, replace defective wall switch. If okay, jumperwires across wall switch wires at valve, if burner comes on, wires are faulty or connections are bad. IMPORTANT NOTE: If an optional *remote switch is used for burner operation, if the standard burnerOFF/ON switch is still installed onappliance it must be in the "OFF" position. B. Thermopile may...

Este manual também é adequado para os modelos :
Lareiras - DIRECT VENT SSDVR-3530CNE (1.77 mb)
Lareiras - DIRECT VENT SSDVR-3530CNM (1.77 mb)
Lareiras - DIRECT VENT SSDVR-4035CNE (1.77 mb)
Lareiras - DIRECT VENT SSDVR-4035CNM (1.77 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias