Log:
Assessments - 4, GPA: 4.3 ( )

Instruções de Operação Superior, Modelo SSBV-4035CNE

Fabricante : Superior
Arquivo Tamanho: 4.4 mb
Arquivo Nome :
Língua de Ensino: enfr
Ir para baixar



Facilidade de uso


6 - Reinstall the switch/bracket assembly. 7 - Reinstall the scoop and lintel. 8 - Reinstall the glass enclosure panel. 9 - Re-Installthebottomcontrolcompartment access door. 10 -The appliance should then relight and remain lit. If this does not occur, check unit for a blocked flue condition. Spill Switch (Blocked Flue Safety Limit) Location -See Figures 6, 7 & 8. Inside View of Firebox -Top/Right Side Intersection Figure6Wire Terminals Cabinet Corner Back of Spill Switch (high limit disc) Door Frame Figure8Spill Switch (limit disc) Bracket Securing Screws Spill Switch (limit disc) View Without Scoop Figure7Firebox Top Lintel Securing Screw Hole in Cabinet Top Scoop Securing Screws Scoop Lintel Securing Screw Hole in Cabinet Top Figure8Spill Switch (limit disc) Bracket Securing Screws Spill Switch (limit disc) View Without Scoop Figure7Firebox Top Lintel Securing Screw Hole in Cabinet Top Scoop Securing Screws Scoop Lintel Securing Screw Hole in Cabinet Top Firebox Top Outside Combustion Air Controls WARNING Do not operate the shutoff lever unless a completeoutside COM BUSTION air system has been installed with your appliance. Many appliances are equipped, when installed, with an outside (make-up air) vent system that isdesignedtoprovidetheappliancewithoutside make-up air for combustion when in operation. The combustion air control lever for the outside air system is standard on all appliances but should not be operated if the complete system is not installed. Refer to Figures 9 & 10. When thecompleteoutsideairventsystemisinstalled, theinstallerwillremovethesecuringscrewfrom the combustion air control lever located on the left side of the fireplace bottom opening. If the securing screw has not been removed and you have reason to believe that you have a complete outside air system, contact your distributor to have your appliance inspected for the presence of the complete system. DO NOT assume that you have this system in place. Operate the actuator through several cycles including the closed position. Ensuring proper operation and freedom of movement. Return the actuator arm to the closed position. Toopentheoutsideairshutter,removethebottom louvered control comartement door, reach into control compartment and pull the combustion air controlleverallthewayout.Theoutsideairshutter should be fully open when the fireplace is in use and completely closed when the fireplace is not beingused. Closingitwhennotinusewillprevent outside cold air from entering the dwelling. Outside Air Control Lever Air Shutter in Closed Position Outside Air Control Lever Securing ScrewFigure9 Figure10Outside Air Control Lever and Securing Screw Location on Left Side of Cabinet in Lower Control Compartment Area Outside Air Control Lever Outside Air Control Lever Securing Screw Removed Air Shutter in Open Position Front Glass Enclosure Panel, Removal and Installation WARNING Donotoperateappliancewiththe glass front removed, cracked or broken. Replacementoftheglass should be don...

Este manual também é adequado para os modelos :
Lareiras - SSBV-3530CNE (4.4 mb)
Lareiras - SSBV-3530CNE (4.4 mb)
Lareiras - SSBV-3530CNM (4.4 mb)
Lareiras - SSBV-3530CNE (4.4 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias