Log:
Assessments - 4, GPA: 4 ( )

Instruções de Operação Superior, Modelo VF4000-CMP-2

Fabricante : Superior
Arquivo Tamanho: 1 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


2). Replace ODS/pilot assembly or get pilot serviced. F. Thermocouple damaged. Replace thermocouple. G. Control valve damaged. Replace control valve. 7. Burner does not light after ODS/pilot is lit. A. Burner orifice is clogged. Clean burner or replace burner orifice. B. Burner orifice diameter is too small. Replace burner orifice. C. Inlet gas pressure is too low. Contact local gas company. 8. Delayed ignition of burner. A. Manifold pressure is too low. Contact local gas company. B. Burner orifice is clogged. Clean burner or replace burner orifice. 9. Burner backfiring during combustion. A. Burner orifice is clogged or damaged. Clean burner or replace burner orifice. B. Burner damaged. Replace burner. C. Gas regulator defective. Replace gas regulator. 10. Slight smoke or odor during initial operation. A. Vapors from paint or curing process of logs. Problem will stop after a few hours of operation. SFC recommends running the heater with excess ventilation for the first few hours. 11. Heater produces a whistling noise when burner is lit. A. Turning control knob to “HI” position when burner is cold. Turn control knob to “LO” position and let warm up for a minute. B. Air in gas line. Operate burner until air is removed from line. Have gas line checked by local gas company. C. Dirty or partially clogged burner orifice. Clean burner or replace burner orifice. REPLACEMENT PARTS LIST Item No. Description VF4000-CHN (Manual) VF4000-CHP (Manual) VF4000-CMN (Millivolt) VF4000-CMP (Millivolt) Part No. Qty. Part No. Qty. 1. Valve (Natural) H4111 1 – – Valve (Propane) H4111 1 – – SIT Valve (Natural) – – H4173 1 Honeywell Valve (Natural) – – 24M13 1 SIT Valve (Propane) – – H4278 1 Honeywell Valve (Propane) – – 67L02 1 2. Injector, Burner (Natural) H4115 2 H4115 2 Injector, Burner (Propane, LPG) H4116 2 H4116 2 3. Pilot (Natural) H4114 1 H4113 1 Pilot (Propane, LPG) H4112 1 H4170 1 4. Regulator (Natural) H4869 1 903218 1 Regulator (Propane, LPG) H4870 1 112081 1 5. Front Burner H4170 1 H4170 1 6. Rear Burner (Natural) H6430 1 H6430 1 Rear Burner (Propane, LPG) H6430 1 H6430 1 7. Crossover Burner H4110 1 H4110 1 8. Injector, Crossover Burner (Natural) H4118 1 H4118 1 Injector, Crossover Burner (Propane, LPG) H4119 1 H4119 1 9. Piezo 10K86 1 10K86 1 10. Piezo Wire H4868 1 H4868 1 11. Log Set H2335 1 H2335 1 12. Bar, Louver-Black H4317 2 H4317 2 13. Panel, Radiant H4315 2 H4315 2 14. Replacement Screen H4178 1 H4178 1 15. Hood H4141 1 H4141 1 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 19 REPLACEMENT PARTS 9 10 15 14 4 7 6 5 12 1 12 13 13 2 8 3 CH Models CM Models CH Models CM Models (SIT Valve Shown) 11 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications and prices, and also to discontinue colors, styles and products . Consult your local distributor for fireplace code information. (Rectangle comment NJC02 07.04.2010 21:08:18 blank) LHP Printed ...

Este manual também é adequado para os modelos :
Lareiras - VF4000-CHN-2 (1 mb)
Lareiras - VF4000-CHP-2 (1 mb)
Lareiras - VF4000-CHN-2 (1 mb)
Lareiras - VF4000-CHN-2 (1 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias