Instruções de Operação Desa, Modelo (V)B36I

Fabricante : Desa
Arquivo Tamanho: 1.97 mb
Arquivo Nome :
Língua de Ensino: enfr
Ir para baixar



Facilidade de uso


Combustible materials above 9" and projecting more than 1 1/2" from fireplace must not be placed less than 12" from top opening of fireplace (NFPA STD 211, Sec. 7-3.3.3). Mantels or any other combustible material may come up to side edge of black metal face of fireplace if projection from front face falls within limits shown in Figure 5. Fan/Blower Kit assembly Fan or blower kit is optional with this fireplace (for circulating models only). Use of blowers or fans other than those manufactured by DESA Heating, LLC voids warranty. Fan is operated by pressing rocker switch (see Figure 6) in lower right hand corner of fireplace face. Blower is operated by turning control knob (not shown). Fan/blower kit electrical connections are made through electrical cover plate on side of fireplace a shown in Figure 6. Wiring Instructions 1. Remove electrical cover plate with bushing from fireplace by removing 2 sheet metal screws as shown in Figure 6. 2. Slide power source wiring through electrical bushing opening and electrical cover plate and make all necessary connections. 3. Slide all wiring connections in electrical housing as shown in Figure 6. 4. Secure electrical cover plate with screws previously removed. Note: Electrical housing and cover plate have sharp edges. Wear protective gloves. Fireplace Installation Continued Sheet Metal Screws 12 1/4" Ref. 1 1/2" Max. Upper Sectionof CirculatingFireplace6" Ref. 6" Min. 33° 3" Nom.*Note: DrawingNot To ScaleSafe Zone ForProjection ofCombustibleMaterialsCombustibleMaterial12" Min. 9" Min. Fireplace OpeningTop of LouveredOpening Electrical Cover Plate Rocker Switch Electrical Bushing Outer Wrapper of Fireplace Wire Nut (3x) (Not Supplied) Electrical Housing Power Source Wiring (Not Supplied) To Power Source Electrical Cover Plate and Electrical Bushing Receptacle (Supplied) Fireplace Chassis Ground Prewired Receptacle and Ground Figure 4 - Mantel Clearances to Combustible Material Figure 6 - Fan Switch-Electrical Bushing FIREBOXSAFE ZONE Top View of Fireplace 0.625" Max. 9" 1" 33° Min. 12" from Perpendicular Side Wall Figure 5 - Side Mantel Clearance Venting Installation Optional Outside air Kit (Model AK4/AK4F) Installation of outside air kit should be performed during rough framing of fireplace due to the nature of it's location. Outside combustion air is accessed through a vented crawl space (AK4F) or through a sidewall (AK4). See Figure 24 on page 15 for instruction of operating air kit. CAUTION: Combustion air inlet ducts shall not terminate in attic space. The maximum height for the air vent can not exceed 3 feet below the flue gas outlet of the termination. Chimney Pipe DESA Heating, LLC chimney system consists of 12", 18", 24", 36" and 48" snap-lock, double-wall pipe segments, planned for maximum adaptability to individual site requirements. Actual lengths gained after fitting overlaps must be taken into consideration (lineal gain) and are given in lineal gain chart (see Figure 8). Lineal gain is actual measurable length of a part after two or more parts are connected. WARNING: The opening in collar around chimney at top of fireplace must not be obstructed. Never use blown insulation to fill chimney enclosure. 12 3/8" Galvanized Outer Pipe Hemmed End 8" Stainless Inner Pipe LINEAL GAIN PART NO. DESCRIPTION GAIN 36" Fireplace 37 1/2" 12-8DM 12-8HT Pipe Section 10 5/8" 18-8DM 18-8HT Pipe Section 16 5/8" 24-8DM 24-8HT Pipe Section 23 5/8" 36-8DM 36-8HT Pipe Section 34 5/8" 48-8DM 48-8HT Pipe Section 46 5/8" RT-8DM RT-8HT Round Termination 6 7/8"* RTL-8DM RTL-8HT Round Termination 7 3/4"* RTT-8DM RTT-8HT Round Termination with Slip Section 6 7/8" to 23 1/8"* RTTL-8DM RTTL-8HT Round Termination with Slip Section 8 1/2" to 21 1/2"* ET-8DM ET-8HT Square Chase-Top 12"* ETO-8DM Square Chase-Top with Mesh 12"* ETL-8DM ETL-8HT Square Chase-Top with Slip Section 7" to 15"* ETLO-8DM Square Chase-Top with Mesh & Slip Section 12" to 25 1/2"* * The lineal gain for the terminations is measured to the flue gas outlet height. Secure to Collars with Metal Tape, Screws or Straps (Min. of 1/4" x 20" in size) Air Inlet Location Must Allow For Bushes or Snow Air Inlet Eyebrow Vented Crawl Space (Check Local Codes Before Installing in a Vented Crawl Space) Vent Hood Required for Wall Installation Figure 7 - Outside Air Kit Figure 8 - Lineal Gain Assembly and installation of double wall chimney system Each double wall chimney section consists of a galvanized outer pipe, a stainless steel inner flue pipe and a wire spacer. Pipe sections must be assembled independently as chimney is installed. When connecting chimney directly to fireplace, inner flue pipe section must be installed first with lanced side up. Outer pipe section can then be installed over flue pipe section with hemmed end up. Press down on each pipe section until lances securely engage hem on fireplace starter. Wire will assure proper spacing between inner and outer pipe sections. Note: For Canada, use chimney parts designated HT...

Este manual também é adequado para os modelos :
Lareiras - (V)B36 (1.97 mb)
Lareiras - (V)B36L (1.97 mb)
Lareiras - (V)B36LI (1.97 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias