Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Enviro, Modelo DV36

Fabricante : Enviro
Arquivo Tamanho: 2.29 mb
Arquivo Nome : DV36-Owners-Manual.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


INSTALLATION INSTRUCTIONS: 1. Plan your installation and clearances to combustibles. Decide on a location for the unit that will meet the clearances noted in the venting section, and any or all local code requirements. 2. Set the appliance in the desired location. Determine if any wall studs, electrical wiring, or plumbing pipes are in the way of the venting system as it passes through the exterior wall. The fireplace location should be adjusted if obstructions are found in the wall. 3. Project a line from the center point of the flue outlet upward and outward to the desired flue outlet location on the exterior wall. Using this center point, scribe a 10” (25.4 cm) hole or square on the wall. Cut the hole from the interior through the exterior wall surfaces. 4. Frame the hole as shown in Figure 29. 5. Trim the wall thimble to match the wall thickness as necessary. Install the wall thimble and secure it to the inner wall frame using four (4) 11.2” wood screws. If a wall is greater than 8” (203mm) in depth, the clearance above the flex must be 43.8” (111mm) 6. Apply a bead of Mill-Pac Black sealant to the new O4” (10 cm) by 5” (12.5 cm) provided flue collar adaptor. Press the flue collar into the flue outlet of the fireplace so that the Mill-Pac seals the flue collar to the flue outlet. 7. Stretch both the O4” (10 cm) flex vent and the O65.8” (16.25 cm) flex intake liner to the length needed to ensure the flex can be easily connected to the vent terminal. 8. Slide the O65.8” (16.25 cm) flex intake liner over the flex vent. Install four (4) wire spacers around the flex pipe. Ensure the wire spacers are positioned at either end of the pipes, and at each end of any elbows in the liners (refer to Figure 25 and 26). 9. Install the flex pipe assembly through the wall thimble, ensure that this portion of pipe slides through the outside wall far enough to connect onto the vent termination cap. ...................... Figure 25: Wire Spacers. Figure 26: Wire Spacer in Place. 1 10. Apply a bead of Mill-Pac Black sealant to the top section of the O4” (10 cm) by 5” (12.5 cm) flue collar adaptor previously installed into the fireplace flue outlet. Slide the O4” (10 cm) flex vent over the flue collar and secure with three (3) sheet metal screws evenly spaced. 11. Place a bead of high temperature silicone on the intake collar of the fireplace, slide the O65.8” (16.25 cm) flex intake liner over the collar, secure the flex liner with three (3) sheet metal screws evenly spaced. 12. On the outside of the exterior wall, apply a bead of Mill-Pac Black sealant to the O4” (10 cm) pipe of the vent terminal. Slide the flex liner onto the vent terminal and secure with three (3) sheet metal screws evenly spaced. 13. Place a bead of high temperature silicone on the intake collar of the vent terminal, slide the O65.8” (16.25 cm) flex intake liner over the collar, secure the flex liner with three (3) sheet metal screws evenly spaced. 14. Attach the vent terminal to the outside of the house using four (4) wood screws provided. 15. Light the appliance and ensure proper operation. OTHER APPROVED VENT PARTS: Table 5: Approved Vent Manufacturers Manufacturer Trade Name Nominal Sizes American Metal Products AmeriVent Direct 4” - 6 5/8” Security Chimneys International LTD Secure Vent 4” - 6 5/8” Selkirk Metalbestos Direct-Temp 4” - 6 5/8” Simpson Dura-Vent Direct Vent GS 4” - 6 5/8” The DV36 fireplace has been tested and certified for use with AMERICAN METAL PRODUCTS “AMERIVENT DIRECT”, SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES. SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “DIRECT-TEMP VENT SYSTEM” kits are available for horizontal and vertical venting. When using Simpson Duravent, it is recommended that, before installation, a bead of RTV High Temperature Silicone should be applied to each outer vent joint, and Mil-Pac to each inner joint. When planning an installation, it will be necessary to select the proper length of vent pipe for the particular requirements. WARNING: Do not mix parts from different vent manufacturers’ systems. Initial Installation QUALIFIED INSTALLERS ONLY FluePipeAdaptorWallFramingWallThimbleFireStopExhaust4"FlexPipeCombusionAir65/8"FlexPipeWireSpacersHorizontalVentTermination Figure 27: Installation of Fireplace Horizontal Vent Kit. 1 EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct Vent GS starting collar in conjunction with Secure Vent, Direct-Temp, and Ameri Vent Direct venting systems. Use of these systems with the Direct Vent GS starting collar is deemed acceptable and does not affect the Intertek WH listing of the appliance. Table 6: Vent part numbers (Must state if galvanized or black wanted, PART NUMBERS). Direct Vent GS Direct-Temp Secure Vent Ameri Vent Direct Description 908 4DT-6 SV4L6 6” pipe length 4D7 7” pipe length 907 4DT-9 9” pipe length 906 4DT-12 SV4L12 4D12 12” pipe length 904 4DT-24 SV4L24 4D2 24” pipe length 903 4DT-36 SV4L36 4D3 36” pipe leng...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias